商品編號: Belden-89463
Belden 89463 High Temp, Plenum Blue Hose 300V 200°C 鐵氟龍耐高溫工業電腦儀表控制電纜
Industrial Data Solutions® — Industrial Twinax
Blue Hose® Cables
78 Ohm • 20 AWG Stranded (7x28) .038″ TC Conductors • Beldfoil® (100% Coverage) + TC Braid Shield (55% Coverage) • TC Drain Wire
Polyethylene Insulation • Blue Sunlight-resistant PVC Jacket (Color Code: Clear, Blue)
Blue Hose UL AWM Style 2464 (300V 80°C) CM CL2
Belden-9463 20 AWG
Allen-Bradley P/N 1770-CD • P-7K-SC-182141-MSHA*
▲1000 ft. and 6000 ft. put-ups also available in Brown, Orange or Purple.
◆10000 ft. put-up available in Brown or Orange only.
†Final put-up length may vary ±10% from length shown.)
Polyethylene Insulation • Blue Sunlight-resistant LDPE Jacket (Color Code: Clear, Blue)
Flooded Direct Burial Blue Hose
Belden-9463DB 20 AWG
Allen-Bradley P/N 1770-CD
78 Ohm • 20 AWG Stranded (42x36) .038″ TC Conductors • Overall Beldfoil (100% Coverage) + TC Braid Shield (85% Coverage)
Polyethylene Insulation • Blue Sunlight-resistant PVC Jacket (Color Code: Clear, Blue)
High-Flex UL AWM Style 2464 Blue Hose CM (300V 60°C)
Belden-9463F 20 AWG
Allen-Bradley P/N 1770-CD • P-7K-SC-182141-MSHA*
78Ohm • 20 AWG Stranded (7x28) .038″ TC Conductors • Overall Beldfoil (100% Coverage) + TC Braid Shield (76% Coverage) • Drain Wire
Plenum • FEP Insulation • Blue FEP Jacket (Color Code: Clear, Blue)
High Temperature 300V 200°C CMP FT6 CL2P
Belden-89463 20 AWG
Allen-Bradley P/N 1770-CD
DCR = DC Resistance • FEP = Fluorinated Ethylene-propylene • LDPE = Low-density Polyethylene • TC = Tinned Copper
*Pennsylvania Department of Environmental Resources and United States Mine Safety and Health Administration Certification.
89463
|
|
Twinax - Blue Hose® Cable
20 AWG stranded (7x28) tinned copper conductors, FEP insulation, overall Beldfoil® (100% coverage) plus a tinned copper braid shield (76% coverage), FEP jacket. |
|
Item # |
Putup |
Ship Weight |
Color |
Notes |
Item Desc |
89463 0061000 |
1,000 FT |
34.000 LB |
BLUE, LIGHT |
C |
2 #20 FEP FS BRD FEP |
89463 0062500 |
2,500 FT |
90.000 LB |
BLUE, LIGHT |
C |
2 #20 FEP FS BRD FEP |
|
Notes: |
|
C = CRATE REEL PUT-UP.
|
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs |
AWG |
Stranding |
Conductor Material |
Dia. (in.) |
1 |
20 |
7x28 |
TC - Tinned Copper |
.038 |
|
Insulation
Insulation Material:
Insulation Material |
FEP - Fluorinated Ethylene Propylene |
|
Outer Shield
Outer Shield Material:
Layer # |
Outer Shield Trade Name |
Type |
Outer Shield Material |
Coverage (%) |
1 |
Beldfoil® |
Tape |
Aluminum Foil-Polyester Tape |
100 |
2 |
|
Braid |
TC - Tinned Copper |
76 |
|
Outer Shield Drain Wire AWG:
AWG |
Stranding |
Drain Wire Conductor Material |
20 |
7x28 |
TC - Tinned Copper |
|
Outer Jacket
Outer Jacket Material:
Outer Jacket Material |
FEP - Fluorinated Ethylene Propylene |
|
Overall Cabling
Overall Nominal Diameter: |
0.203 in. |
Pair
Pair Color Code Chart:
Number |
Color |
1 |
Clear & Blue |
|
Mechanical Characteristics (Overall)
Operating Temperature Range: |
-70°C To +200°C |
UL Temperature Rating: |
200°C |
Bulk Cable Weight: |
36 lbs/1000 ft. |
Max. Recommended Pulling Tension: |
48 lbs. |
Min. Bend Radius (Install)/Minor Axis: |
2.500 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: |
CMP, CL2P |
CEC/C(UL) Specification: |
CMP FT6 |
EU Directive 2000/53/EC (ELV): |
Yes |
EU Directive 2002/95/EC (RoHS): |
Yes |
EU RoHS Compliance Date (mm/dd/yyyy): |
04/01/2005 |
EU Directive 2002/96/EC (WEEE): |
Yes |
EU Directive 2003/11/EC (BFR): |
Yes |
CA Prop 65 (CJ for Wire & Cable): |
Yes |
MII Order #39 (China RoHS): |
Yes |
Customer Part Number Reference Specification: |
Allen Bradley P/N 1770-CD |
Flame Test
Plenum/Non-Plenum
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Nom. Inductance:
Nom. Capacitance Conductor to Conductor:
Nominal Velocity of Propagation:
Nominal Delay:
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft) |
9.5 |
|
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft) |
4.1 |
|
Nom. Attenuation:
Freq. (MHz) |
Attenuation (dB/100 ft.) |
1 |
0.6 |
10 |
2.1 |
50 |
5.0 |
100 |
7.5 |
200 |
11.0 |
400 |
16.0 |
|
Blue Hose UL AWM Style 2464 (300V 80°C) CM CL2
keyword: Belden89463, Plenum Blue Hose, Allen Bradley, P/N 1770-CD,FEP 鐵氟龍耐高溫工業電腦儀表控制電纜
|