商品編號: Belden-9815, google,taiwan
Belden9815 Twinax - 100 Ohm Twinax Coaxial Cable 儀表電腦數據傳輸電線
100 ohm, 20 AWG stranded (7x28) .037" one tinned/ one bare copper conductors, polyethylene insulation, Duofoil® + TC braid shield (95% coverage), high-density polyethylene jacket.
DESCRIPTION:
100 ohm, 20 AWG stranded (7x28) .037" one tinned/ one bare copper conductors, polyethylene insulation, Duofoil® + TC braid shield (95% coverage), high-density polyethylene jacket.
PHYSICAL CHARACTERISTICS :
CONDUCTOR :
Number of Pairs: 1
Total Number of Conductors: 2
AWG: 20
Stranding: 7x28
Conductor Material: TC - Tinned Copper, BC - Bare Copper
INSULATION :
Insulation Material: PE - Polyethylene
PAIR :
Pair Color Code Chart:
Number Color
1 Natural & Natural
INNER JACKET :
Inner Jacket Material: PE - Polyethylene
Inner Jacket Diameter: .236 in.
OUTER SHIELD :
Outer Shield Trade Name: Duofoil®
Outer Shield Type: Tape/Braid
Outer Shield Material:
Layer Number Material Trade Name Type Material % Coverage (%)
1 Duofoil® Tape Aluminum Foil-Polyester Tape-Aluminum Foil 100
2 Braid TC - Tinned Copper 95
Outer Shield %Coverage: 100 %
Outer Shield Flooding Grease: Polyethylene Grease
OUTER JACKET :
Outer Jacket Material: HDPE - High Density Polyethylene
OVERALL NOMINAL DIAMETER :
Overall Nominal Diameter: .330 in.
MECHANICAL CHARACTERISTICS :
Operating Temperature Range: -55°C To +80°C
Bulk Cable Weight: 60.5 lbs/1000 ft.
Max. Recommended Pulling Tension: 115 lbs.
Min. Bend Radius (Install): 3.5 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE :
APPLICABLE STANDARDS :
EU CE Mark (Y/N): Yes
EU RoHS Compliant (Y/N): Yes
EU RoHS Compliance Date (mm/dd/yyyy):: 01/01/2004
SUITABILITY :
Suitability - Burial: Yes
PLENUM/NON-PLENUM :
Plenum (Y/N): N
ELECTRICAL CHARACTERISTICS :
Nom. Characteristic Impedance: 100 Ω
Nom. Inductance: 0.155 µH/ft
Nom. Capacitance Conductor to Conductor @ 1 KHz: 14.5 pF/ft
Nom. Cap. Cond. to Other Cond. & Shield @ 1 KHz: 23.0 pF/ft
Nominal Velocity of Propagation: 66 %
Nominal Delay: 1.54 ns/ft
Nom. Conductor DC Resistance @ 20 Deg. C: 9.5 Ω/1000 ft
Nominal Outer Shield DC Resistance: 2 Ω/1000 ft
Nom. Attenuation:
Description Frequency (MHz) Start Frequency (MHz) Stop Frequency (MHz) Nom. Attenuation (dB/100 ft.)
1 0.4
10 1.1
50 2.5
100 4.1
200 6.4
400 10.2
Max. Operating Voltage - Non-UL: 600 V RMS
PUT-UPS AND COLORS:
Item Description Put-Up (ft.) Ship Weight (lbs.) Jacket Color Notes
9815 0101000 TW PR #20 PE PE BRD PE 1000 69 BLACK C
9815 0102000 TW PR #20 PE PE BRD PE 2000 134 BLACK C
9815 010500 TW PR #20 PE PE BRD PE 500 34.5 BLACK
C = CRATE REEL PUT-UP.
|
|
|
|
|