| | 1335A | | Multi-Conductor - DataBus® ISA/SP-50 FOUNDATION Fieldbus or PROFIBUS Cable 1 pair, 16 AWG stranded (7x24) tinned copper conductors, polyolefin insulation, Beldfoil® shield (100% coverage) plus a tinned copper braid shield (65% coverage), tinned copper drain wire, oil-resistant PVC jacket. | | Item # | Putup | Ship Weight | Color | Notes | Item Desc | 1335A 0031000 | 1,000 FT | 65.000 LB | ORANGE | C | 1 PR #16 PP SH FRPVC | 1335A 0031640 | 1,640 FT | 106.600 LB | ORANGE | C | 1 PR #16 PP SH FRPVC | 1335A 0033280 | 3,280 FT | 213.200 LB | ORANGE | C | 1 PR #16 PP SH FRPVC | 1335A 003394 | 394 FT | 27.186 LB | ORANGE | C | 1 PR #16 PP SH FRPVC | 1335A 0061000 | 1,000 FT | 65.000 LB | BLUE, LIGHT | C | 1 PR #16 PP SH FRPVC | 1335A 0061640 | 1,640 FT | 106.600 LB | BLUE, LIGHT | C | 1 PR #16 PP SH FRPVC | 1335A 0063280 | 3,280 FT | 213.200 LB | BLUE, LIGHT | C | 1 PR #16 PP SH FRPVC | 1335A 006394 | 394 FT | 27.186 LB | BLUE, LIGHT | C | 1 PR #16 PP SH FRPVC | | Notes: | | C = CRATE REEL PUT-UP. | Physical Characteristics (Overall) Conductor AWG: # Pairs | AWG | Stranding | Conductor Material | 1 | 16 | 7x24 | TC - Tinned Copper | | Insulation Insulation Material: Insulation Material | PO - Polyolefin | | Outer Shield Outer Shield Material: Layer # | Outer Shield Trade Name | Type | Outer Shield Material | Coverage (%) | 1 | Beldfoil® | Tape | Aluminum Foil-Polyester Tape | 100 | 2 | | Braid | TC - Tinned Copper | 65 | | Outer Shield Drain Wire AWG: AWG | Stranding | Drain Wire Conductor Material | 20 | 7x28 | TC - Tinned Copper | | Outer Jacket Outer Jacket Material: Outer Jacket Material | PVC - Polyvinyl Chloride | | Outer Jacket Ripcord: | Yes | Overall Cabling Overall Nominal Diameter: | 0.340 in. | Pair Pair Color Code Chart: Number | Color | 1 | Blue & Orange | | Pair Lay Length & Direction: Mechanical Characteristics (Overall) Operating Temperature Range: | -30°C To +90°C | UL Temperature Rating: | 90°C | Max. Recommended Pulling Tension: | 84 lbs. | Min. Bend Radius (Install)/Minor Axis: | 3.400 in. | Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: | CM, ITC, PLTC | CEC/C(UL) Specification: | CM | EU Directive 2000/53/EC (ELV): | Yes | EU Directive 2002/95/EC (RoHS): | Yes | EU RoHS Compliance Date (mm/dd/yyyy): | 09/05/2006 | EU Directive 2002/96/EC (WEEE): | Yes | EU Directive 2003/11/EC (BFR): | Yes | CA Prop 65 (CJ for Wire & Cable): | Yes | MII Order #39 (China RoHS): | Yes | Flame Test UL Flame Test: | UL1685 UL Loading | Suitability Suitability - Indoor: | Yes | Suitability - Outdoor: | Yes | Plenum/Non-Plenum Electrical Characteristics (Overall) Unaveraged Impedance: Description | Freq. (MHz) | Start Freq. (MHz) | Stop Freq. (MHz) | Impedance (Ohm) | | .03125 | | | 100 | | Nom. Capacitance Conductor to Shield: Nom. Mutual Capacitance: Maximum Capacitance Unbalance: Nominal Velocity of Propagation: Nom. Conductor DC Resistance: DCR @ 20°C (Ohm/1000 ft) | 4.200 | | Maximum Outer Shield DC Resistance: DCR @ 20°C (Ohm/1000 ft) | 4.9 | | Nom. Attenuation: Description | Freq. (MHz) | Start Freq. (MHz) | Stop Freq. (MHz) | Attenuation (dB/100 ft.) | | .039 | | | .066 | | Max. Attenuation: () | Freq. (MHz) | Attenuation (dB/100 ft.) | .091 | 0.039 | 0.091 | | Max. Operating Voltage - UL: Max. Recommended Current: Description | Current | Per Conductor | 8 Amps | | Other Electrical Characteristic 1: | Max Propagation Delay Change From 7.812 kHz to 39.06 kHz: 518 pS/ft | Other Electrical Characteristic 2: | 31.25 KBits/sec | |
| |
|
|