1. Belden- Belden® DataTuff® Cable
    Belden- Power Over Ethernet (POE) 以太網供電傳輸系統
    Belden- Solar & Wind Turbine Tray Cable太陽能 風力發電渦輪機用線
    Belden-Hirschmann™ Robust Unmanaged OCTOPUS Switch
    Belden-Industrial Fiber 工業級光纖電纜線
    Belden-Industrial Twinax Blue Hose® Cables
    Belden-Shipboard Audio Control and Instrumentation Cable
    Belden-工業( DeviceBus for ODVA DeviceNet™)用線
    Belden-工業(300V, Tray Cable)電線
    Belden-工業(600V,Tray Cable)電線
    Belden-工業(High-Temp/Thermocouple-Cable)高溫補償導線
    Belden-工業(Industrial Ethernet乙太網路)用線
    Belden-工業(Industry-PLC/DCS)用線
    Belden-工業(Thermocouple-Cable)補償導線
    Belden-工業(ULControl/Intrumentation)儀控用線
    Belden-工業InfinityFlex)用線
    Belden-工業RS-485用線
    Belden-工業-VFD(Variable Frequency Drive)變頻馬達控制用線
    Belden-工業級(Industrial Ethernet DataTuff® RJ45 Cord Set) 乙太網路跳接線
    Belden-工業級(Industrial Ethernet乙太網路)用線
    Belden-工業電腦(FOUNDATION Fieldbus or PROFIBUS Cable)用線
    Belden-工業電腦(PROFIBUS/Controlnet/QuadShielded Cable)用線
    Hirschmann-Ethernet Converters with Serial Interface
    Lumberg Automation™-Sensor Connectors
    Belden-MachFlex 350 Industrial Cables PVC工業級機械組裝電纜
    Belden-PROFINET Cable
    回上一頁
  2. 產品搜尋
    分 類:
    關鍵字:  

    首頁 > > Belden-工業電腦(FOUNDATION Fieldbus or PROFIBUS Cable)用線

    Belden-(SI1341A, SI1342A, SI1343A, SI1344A) MultiPairs Type A 18 AWG 600V DataBus® for FOUNDATION Fieldbus or Profibus PA
    看原圖
    5345151




    商品編號: Belden-SI1341A

    Belden-(SI1341A, SI1342A, SI1343A, SI1344A) MultiPairs Type A 18 AWG 600V DataBus® for FOUNDATION Fieldbus or Profibus PA


    Fieldbus Type A and Type B cables provide installation flexibility in many
    different environments, including outdoors, and where multiple or
    extended cable runs are required.




    ★★★★商品說明★★★★

    SI1341A
       Multi-Conductor - DataBus® ISA/SP-50 FOUNDATION Fieldbus or PROFIBUS Cable
    18 AWG stranded (7x26) tinned copper conductors, polyolefin insulation, polyolefin fillers, Beldfoil® shield (100% coverage), tinned copper drain wire, polypropylene separator, oil & sunlight resistant PVC jacket.
    For more Information
    please call

    1-800-Belden1
    Put Ups and Colors:
    Item # Putup Ship Weight Color Notes Item Desc
    Physical Characteristics (Overall)
    Conductor
    AWG:
    # Conductors # Pairs AWG Stranding Conductor Material
    1 12 18 7x26 TC - Tinned Copper
    Ground Wire
    Ground Wire (Y/N): Y
    Ground Wire AWG: 18
    Ground Wire Stranding: 7x26
    Ground Wire Conductor Material: TC - Tinned Copper
    Ground Wire Insulation Material: PVC - Polyvinyl Chloride
    Insulation
    Insulation Material:
    Insulation Material
    FRPO - Flame Retardant Polyolefin
    Inner Shield
    Inner Shield Material:
    Inner Shield Trade Name Type Inner Shield Material Coverage (%)
    Beldfoil® Tape Aluminum Foil-Polyester Tape 100
    Inner Shield Drain Wire AWG:
    AWG Stranding Conductor Material
    18 7x26 TC - Tinned Copper
    Outer Shield
    Outer Shield Material:
    Outer Shield Trade Name Type Outer Shield Material Coverage (%)
    Beldfoil® Tape Aluminum Foil-Polyester Tape 100.000
    Outer Shield Drain Wire AWG:
    AWG Stranding Drain Wire Conductor Material
    20 7x28 TC - Tinned Copper
    Outer Jacket
    Outer Jacket Material:
    Outer Jacket Material
    PVC - Polyvinyl Chloride
    Overall Cabling
    Overall Nominal Diameter: 1.010 in.
    Pair
    Pair Color Code Chart:
    Number Color
    1 Blue and Orange and Numbered 1
    2 Blue and Orange and Numbered 2
    3 Blue and Orange and Numbered 3
    4 Blue and Orange and Numbered 4
    5 Blue and Orange and Numbered 5
    6 Blue and Orange and Numbered 6
    7 Blue and Orange and Numbered 7
    8 Blue and Orange and Numbered 8
    9 Blue and Orange and Numbered 9
    10 Blue and Orange and Numbered 10
    11 Blue and Orange and Numbered 11
    12 Blue and Orange and Numbered 12
    13 Green/Yellow (Ground)
    Mechanical Characteristics (Overall)
    Operating Temperature Range: -30°C To +75°C
    UL Temperature Rating: 75°C
    Max. Recommended Pulling Tension: 560 lbs.
    Min. Bend Radius (Install)/Minor Axis: 10.100 in.
    Applicable Specifications and Agency Compliance (Overall)
    Applicable Standards & Environmental Programs
    NEC/(UL) Specification: TC-ER
    EU CE Mark: Yes
    EU Directive 2000/53/EC (ELV): Yes
    EU Directive 2002/95/EC (RoHS): Yes
    EU RoHS Compliance Date (mm/dd/yyyy): 11/01/2007
    EU Directive 2002/96/EC (WEEE): Yes
    EU Directive 2003/11/EC (BFR): Yes
    CA Prop 65 (CJ for Wire & Cable): Yes
    MII Order #39 (China RoHS): Yes
    Flame Test
    UL Flame Test: UL1685 UL Loading
    Suitability
    Suitability - Indoor: Yes
    Suitability - Outdoor: Yes
    Sunlight Resistance: Yes
    Oil Resistance: Yes
    Plenum/Non-Plenum
    Plenum (Y/N): No
    Electrical Characteristics (Overall)
    Unaveraged Impedance:
    Freq. (MHz) Impedance (Ohm)
    0.031 100.000
    Nom. Inductance:
    Inductance (µH/ft)
    0.220
    Nom. Capacitance Cond. to Other Conductor & Shield:
    Capacitance (pF/ft)
    45.000
    Nom. Mutual Capacitance:
    Capacitance (pF/ft)
    24.000
    Maximum Capacitance Unbalance:
    Capacitance (pF/ft)
    1.200
    Nom. Conductor DC Resistance:
    DCR @ 20°C (Ohm/1000 ft)
    5.860
    Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: 7.500 Ohm/1000 ft
    Nom. Attenuation:
    Freq. (MHz) Attenuation (dB/100 ft.)
    0.039 0.080
    Max. Attenuation:
    Freq. (MHz) Attenuation (dB/100 ft.)
    0.039 0.091
    Max. Operating Voltage - UL:
    Voltage
    600 V RMS
    Max. Recommended Current:
    Description Current
    Per Conductor 5.2 Amps
    Other Electrical Characteristic 1: Max. Propagation Delay Change From 7.812 kHz to 39.06 kHz: 518 pS/ft
    Other Electrical Characteristic 2: 31.25 KBits/sec

     


    ★★★★使用操作說明★★★★

    Fieldbus Specification
    IEC 61158-2 (ISA/SP-50)


    Fieldbus is an all-digital, serial, two-way
    communications protocol that standardizes
    the interconnection of field devices at a
    communications rate of 31.25 kB/s. The field
    devices are made accessible to communication
    networks (running at 1 or 2.5 Mb/s), through
    use of linking devices. Because a simple twisted
    pair of wires can carry the signals between the
    field devices and the networks, Fieldbus users can
    reduce the amount of I/O and control equipment
    (due to distribution of control into the field
    devices), plus they can use fewer Intrinsically
    Safe (IS) barriers, cabinets, cables and connectors.
    And, since the wire pair can support multiple
    functions within a single device (such as
    diagnostics, control and auto error correction),
    the twisted pair cable becomes the integral
    part of a more efficient, more reliable, and
    more cost-effective industrial control system.
     

    Why FOUNDATION Fieldbus?


    With FOUNDATION Fieldbus, end users have the
    freedom to implement tightly integrated digital
    control based on a unified system architecture
    and a high-speed backbone (HSE) for plant
    operations. This, in turn, removes the constraints
    on device and sub-system interoperability.
     

    Fieldbus Cabling Features


    The number of devices possible on a fieldbus link
    will vary depending on factors such as the power
    consumption of each device, the use of repeaters,
    signal attenuation, type of cable used and distance.
    The table below provides suggested transmission
    distances (cable lengths) for each type of cable.
    Because of the superior features of Belden
    DataBus cables, distance limitations can be
    exceeded without any system enhancements
    or any sacrifice in system performance.
    Belden Fieldbus cable features include:
    • Compliant with Fieldbus Spec IEC 61158-2
    (ISA/SP-50)
    • Excellent electrical characteristics
    • Low capacitance (for long runs)
    • Versions in 22, 18, 16 and 14 AWG stranded
    tinned copper conductors
    • Standard multi-pair cables available in 2 to 24
    pairs in 300V and LSZH or 600V designs
    • Versions available with Beldfoil® shields and
    Beldfoil Plus Braid shields
    • PLTC/ITC-ER, PLTC, and TC-ER versions available
    • Easily identifiable Orange jacket
    • Blue jacket available for
    Intrinsically Safe applications
    • Suitable for use in Class 1, Div. 2 applications
    • RoHS compliant and CE approved
    • CMX-Outdoor rated as listed

    Fieldbus High Speed Ethernet (HSE) Cables


    Fieldbus has chosen Ethernet for HSE control
    backbone 100Mb/s transmissions. To help you
    with your selection of Category 5e and Category 6
    cables, Belden offers its DataTuff® Industrial Ethernet
    Cable Selection Guide. For more information on
    Belden DataTuff cables, please call Belden or ask
    for the Industrial Ethernet New Product Bulletin.
    Custom Cable Constructions
    As always with Belden industrial cables,
     

    custom constructions are available:

    • Aluminum or Steel Interlocked Armor
    • CPE jacket or LSOH jacket
    • Various jacket colors
    • Alternate Black and White color-coded pairs
    • Multi-pair Type A, 300V, individually and
    overall shielded and PVC jacketed with up to
    50-pair capability
    • Multi-pair Type B 22 AWG, PLTC-rated,
    individually and/or overall shielded