商品編號: Belden-3094A
Belden-3094A ControlBus™ RG-11/U Type Quad Shielded Coax 自動化工業電腦Controlnet控制資料傳輸線
DESCRIPTION:
14 AWG solid bare copper-covered steel conductor, gas-injected foam polyethylene insulation, Duobond® IV quad shield (100% coverage), PVC Jacket.
SUITABLE APPLICATIONS :
Suitable Applications: RG-11/U Type
PHYSICAL CHARACTERISTICS :
CONDUCTOR :
Number of Coax: 1
Total Number of Conductors: 1
RG Type: 11/U
AWG: 14
Stranding: Solid
Conductor Diameter: .064 in.
Conductor Material: BCCS - Bare Copper Covered Steel
INSULATION :
Insulation Material: Gas-injected FPE - Foam Polyethylene
Insulation Diameter: .280 in.
OUTER SHIELD :
Outer Shield Material Trade Name: Duobond® IV
Outer Shield Type: Tape/Braid/Tape/Braid
Outer Shield Material:
Layer Number Trade Name Type Material % Coverage (%)
1 Duofoil® Tape Bonded Aluminum Foil-Polyester Tape-Aluminum Foil 100
2 Braid AL - Aluminum 60
3 Duofoil® Tape Aluminum Foil-Polyester Tape-Aluminum Foil 100
4 Braid AL - Aluminum 40
Outer Shield %Coverage: 100 %
OUTER JACKET :
Outer Jacket Material: PVC - Polyvinyl Chloride
OVERALL NOMINAL DIAMETER :
Overall Nominal Diameter: .407 in.
MECHANICAL CHARACTERISTICS :
Operating Temperature Range: -40°C To +80°C
Bulk Cable Weight: 59 lbs/1000 ft.
Max. Recommended Pulling Tension: 308 lbs.
Min. Bend Radius (Install): 4.5 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE :
APPLICABLE STANDARDS :
NEC/(UL) Specification: CL2R, CMR
CEC/C(UL) Specification: CMG
EU RoHS Compliant (Y/N): Yes
EU RoHS Compliance Date (mm/dd/yyyy):: 01/01/2004
FLAME TEST :
UL Flame Test: UL1666 Riser
CSA Flame Test: FT4
PLENUM/NON-PLENUM :
Plenum (Y/N): N
Plenum Number: 3095A
ELECTRICAL CHARACTERISTICS :
Nom. Characteristic Impedance: 75 +/- 3 Ω
Nom. Inductance: .097 µH/ft
Nom. Capacitance Conductor to Shield: 16.2 pF/ft
Nominal Velocity of Propagation: 82 %
Nominal Delay: 1.2 ns/ft
Nom. Conductor DC Resistance @ 20 Deg. C: 11.0 Ω/1000 ft
Nominal Outer Shield DC Resistance @ 20 Deg.C: 1.5 Ω/1000 ft
Minimum Structural Return Loss:
Description Frequency (MHz) Start Frequency (MHz) Stop Frequency (MHz) Minimum Structural Return Loss (dB)
5 400 20
Nom. Attenuation:
Description Frequency (MHz) Start Frequency (MHz) Stop Frequency (MHz) Nom. Attenuation (dB/100 ft.)
1 .16
2 .18
5 .26
10 .38
20 .55
50 .83
100 1.17
200 1.60
300 1.99
400 2.30
Max. Attenuation:
Description Frequency (MHz) Start Frequency (MHz) Stop Frequency (MHz) Max. Attenuation (dB/100 ft.)
1 .33
2 .35
5 .44
10 .66
20 .78
50 .99
100 1.32
200 1.87
300 2.29
400 2.64
Max. Operating Voltage - UL: 600 V RMS
NOTES :
Notes: Sweep tested 5 to 400 MHz. Tap marks every 2.6 Meters to aid users in installation.
PUT-UPS AND COLORS:
Item Description Put-Up (ft.) Ship Weight (lbs.) Jacket Color Notes
3094A F2V1000 #14 GIFHDLDPE DSH PVC 1000 67 GRAY, DEC
3094A F2V2000 #14 GIFHDLDPE DSH PVC 2000 136 GRAY, DEC C
3094A F2V500 #14 GIFHDLDPE DSH PVC 500 34.5 GRAY, DEC
C = CRATE REEL PUT-UP. |
|
|