商品編號: Belden-3093A
Belden-3093A Coax - ControlNet™ FFEP-PVDF Quad Shielded Coax 工業電腦ControlNet™鐵氟龍耐高溫訊號傳輸線
18 AWG solid bare copper-covered steel conductor, foam FEP insulation, Duobond® IV Quad Shield (100% coverage), fluorocopolymer Jacket.
DESCRIPTION:
18 AWG solid bare copper-covered steel conductor, foam FEP insulation, Duobond® IV Quad Shield (100% coverage), fluorocopolymer Jacket.
PHYSICAL CHARACTERISTICS :
CONDUCTOR :
Number of Coax: 1
Total Number of Conductors: 1
RG Type: 6/U
AWG: 18
Stranding: Solid
Conductor Diameter: .040 in.
Conductor Material: BCCS - Bare Copper Covered Steel
INSULATION :
Insulation Material: FFEP - Foam Fluorinated Ethylene Propylene
Insulation Diameter: .170 in.
OUTER SHIELD :
Outer Shield Material Trade Name: Duobond® IV Quad Shield
Outer Shield Type: Tape/Braid/Tape/Braid
Outer Shield Material:
Layer Number Trade Name Type Material % Coverage (%)
1 Bonded Duofoil® Tape Bonded Aluminum Foil-Polyester Tape-Aluminum Foil 100
2 Braid AL - Aluminum 60
3 Duofoil® Tape Aluminum Foil-Polyester Tape-Aluminum Foil 100
4 Braid AL - Aluminum 40
Outer Shield %Coverage: 100 %
OUTER JACKET :
Outer Jacket Material: PVDF - Fluorocopolymer
OVERALL NOMINAL DIAMETER :
Overall Nominal Diameter: .274 in.
MECHANICAL CHARACTERISTICS :
Operating Temperature Range: -20°C To +150°C
Non-UL Temperature Rating: 150°C
Bulk Cable Weight: 43 lbs/1000 ft.
Max. Recommended Pulling Tension: 104 lbs.
Min. Bend Radius (Install): 2.75 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE :
APPLICABLE STANDARDS :
NEC/(UL) Specification: CMP
CEC/C(UL) Specification: CMP FT6
EU RoHS Compliant (Y/N): Yes
EU RoHS Compliance Date (mm/dd/yyyy):: 04/01/2005
FLAME TEST :
UL Flame Test: NFPA 262
SUITABILITY :
Suitability - Outdoor: Yes
Suitability - Burial: Yes
ELECTRICAL CHARACTERISTICS :
Nom. Characteristic Impedance: 75 Ω
Nom. Inductance: .093 µH/ft
Nom. Capacitance Conductor to Shield: 16.3 pF/ft
Nominal Velocity of Propagation: 82 %
Nominal Delay: 1.28 ns/ft
Nom. Conductor DC Resistance @ 20 Deg. C: 28.0 Ω/1000 ft
Nominal Outer Shield DC Resistance @ 20 Deg.C: 3.6 Ω/1000 ft
Minimum Structural Return Loss:
Description Frequency (MHz) Start Frequency (MHz) Stop Frequency (MHz) Minimum Structural Return Loss (dB)
5 50 23
Nom. Attenuation:
Description Frequency (MHz) Start Frequency (MHz) Stop Frequency (MHz) Nom. Attenuation (dB/100 ft.)
1 .36
2 .38
5 .50
10 .65
20 .95
50 1.50
100 2.12
200 2.99
300 3.66
400 4.23
Max. Operating Voltage - Other: 300 V RMS
NOTES :
Notes: Blue available as standard in 1000-ft put-up only. Suitable for Outdoor and Direct Burial applications.
PUT-UPS AND COLORS:
Item Description Put-Up (ft.) Ship Weight (lbs.) Jacket Color Notes
3093A 0101000 #18 FFEP DBSH SLF 1000 40 BLACK C
3093A 0102000 #18 FFEP DBSH SLF 2000 80 BLACK C N
3093A 0102500 #18 FFEP DBSH SLF 2500 95 BLACK C N
3093A X7E1000 #18 FFEP DBSH SLF 1000 40 BLUE X7E C
C = CRATE REEL PUT-UP.
N = FINAL PUT-UP LENGTH MAY VARY -0% TO +10% FROM LENGTH SHOWN. |
|
|
|
|