商品編號: Belden-7918A
Belden 7918A Industrial Ethernet- Category 5e DataTuff® Twisted Pair Cable 工業級 CAT 5e 網路線(防油 抗陽光)
工業級的電纜可提供更穩定的電氣性能,較少的衰減和更大的抗EMI / RFI。另外,有試驗證明,我們的工業以太網電纜提供:
- 溶劑,油,化學品和水分的滲透和降解防範
- 的耐紫外線輻射和溫度變化
- 優越的機械穩定性,能承受拉力,耐磨,粉碎,直通和埋葬
- MSHA採礦審批
- 紅色外被覆指定安全網絡
許多版本我們DataTuff電纜採用Belden的專利的粘連線對技術。這種結構特徵加蓋以確保沒有搶劫性能差距可以開發之間的導體對導體絕緣電纜對沿其縱軸。其結果是,總是均勻的導體,導體的間距或同心度- ,這反過來,可確保優秀的和始終如一的可靠的電氣性能,即使在嚴酷的安裝。貝爾登調用這個獨特的能力,可安裝性能®,增強6 DataTuff類別5e類和5e類電纜非屏蔽和屏蔽保稅線對電纜與重型,石油和抗紫外線外套,許多以太網/ IP兼容;無護套和鎧裝版本最極端的地區。6類DataTuff雙絞線電纜,4對,保稅對重型陽光和耐油外被覆
Multi-Conductor - Category 5e DataTuff® Twisted Pair Cable
24 AWG solid bare copper conductors, twisted pairs, polyolefin insulation, industrial grade sunlight- and oil-resistant PVC jacket, rip cord. Sequential marking at two foot intervals.
Usage (Overall)
Suitable Applications: |
Industrial Ethernet, Harsh Environments, 200MHz Category 5e, Gigabit Ethernet, 100BaseTX, 100BaseVG ANYLAN, 155ATM, 622ATM, NTSC/PAL Component or Composite Video, AES/EBU Digital Audio, AES51, RS-422, CMX - Outdoor, RJ-45 Compatible |
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs |
AWG |
Stranding |
Conductor Material |
4 |
24 |
Solid |
BC - Bare Copper |
|
Insulation
Insulation Material:
Insulation Material |
PO - Polyolefin |
|
Outer Shield
Outer Shield Material:
Outer Shield Material |
Unshielded |
|
Outer Jacket
Outer Jacket Material:
Outer Jacket Material |
Industrial Grade PVC - Polyvinyl Chloride |
|
Outer Jacket Ripcord: |
Yes |
Overall Cabling
Overall Nominal Diameter: |
0.230 in. |
Pair
Pair Color Code Chart:
Number |
Color |
1 |
White/Blue Stripe & Blue |
2 |
White/Orange Stripe & Orange |
3 |
White/Green Stripe & Green |
4 |
White/Brown Stripe & Brown |
|
Mechanical Characteristics (Overall)
Installation Temperature Range: |
-20°C To +75°C |
Operating Temperature Range: |
-40°C To +75°C |
Bulk Cable Weight: |
24 lbs/1000 ft. |
Max. Recommended Pulling Tension: |
35 lbs. |
Min. Bend Radius (Install)/Minor Axis: |
0.500 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: |
CMR, CMX-Outdoor, UL444 |
CEC/C(UL) Specification: |
CMR |
Other Standards: |
11801 Category 5 |
EU Directive 2000/53/EC (ELV): |
Yes |
EU Directive 2002/95/EC (RoHS): |
Yes |
EU RoHS Compliance Date (mm/dd/yyyy): |
01/01/2004 |
EU Directive 2002/96/EC (WEEE): |
Yes |
EU Directive 2003/11/EC (BFR): |
Yes |
CA Prop 65 (CJ for Wire & Cable): |
Yes |
MII Order #39 (China RoHS): |
Yes |
PMSHA Specification: |
P-07-KA060003 |
Telecommunications Standards: |
568-B.2 Cat 5e |
Other Specification: |
NEMA WC-63.1 Category 5e, UL verified to Category 5e |
Flame Test
UL Flame Test: |
UL1666 Riser |
IEEE Flame Test: |
IEEE 1202 per IEEE 383 |
Suitability
Suitability - Outdoor: |
Yes |
Plenum/Non-Plenum
Electrical Characteristics (Overall)
Nom. Mutual Capacitance:
Maximum Capacitance Unbalance (pF/100 m): |
330 |
Nominal Velocity of Propagation:
Maximum Delay:
Delay (ns/100 m) |
510 @ 100MHz |
|
Max. Delay Skew:
Maximum Conductor DC Resistance:
DCR @ 20°C (Ohm/100 m) |
9.38 |
|
Max. Operating Voltage - UL:
Maximum DCR Unbalanced:
DCR Unbalance @ 20°C (%) |
3 |
|
Electrical Characteristics-Premise (Overall)
Premise Cable Electrical Table 1:
Freq. (MHz) |
Max. Attenuation (dB/100 m) |
Min. NEXT (dB) |
Min. PSNEXT (dB) |
Min. ACR (dB) |
Min. PSACR (dB) |
Min RL (dB) |
Min. SRL (dB) |
1 |
2.0 |
65.3 |
62.3 |
63.0 |
60.0 |
20.0 |
23 |
4 |
4.1 |
56.3 |
53.3 |
51.0 |
49.0 |
23.0 |
23.0 |
8 |
5.8 |
51.8 |
48.8 |
46.0 |
43.0 |
24.5 |
24.5 |
10 |
6.5 |
50.3 |
47.3 |
43.0 |
41.0 |
25.0 |
25.0 |
16 |
8.2 |
47.3 |
44.3 |
39.0 |
36.0 |
25.0 |
25.0 |
20 |
9.3 |
45.8 |
42.8 |
36.5 |
33.5 |
25.0 |
25.0 |
25 |
10.4 |
44.3 |
41.3 |
33.9 |
30.9 |
24.3 |
24.3 |
31.25 |
11.7 |
42.9 |
39.9 |
31.0 |
28.0 |
23.6 |
23.6 |
62.5 |
17.0 |
38.4 |
35.4 |
22.0 |
19.0 |
21.5 |
21.5 |
100 |
22.0 |
35.3 |
32.3 |
14.0 |
11.0 |
20.1 |
20.1 |
155 |
28.1 |
32.5 |
29.5 |
4.4 |
1.4 |
15.8 |
|
200 |
32.0 |
30.8 |
27.8 |
4.0 |
1.0 |
15.0 |
|
|
Premise Cable Electrical Table 2:
Freq. (MHz) |
Input (Unfitted) Imp. (Ohms) |
Fitted Impedance |
Min. ELFEXT (dB) |
Min. PSELFEXT (dB) |
1 |
100 ± 15 |
100 ± 15 |
63.8 |
60.8 |
4 |
100 ± 15 |
100 ± 15 |
51.7 |
48.7 |
8 |
100 ± 15 |
100 ± 15 |
45.7 |
42.7 |
10 |
100 ± 15 |
100 ± 15 |
43.8 |
40.8 |
16 |
100 ± 15 |
100 ± 15 |
39.7 |
36.7 |
20 |
100 ± 15 |
100 ± 15 |
37.7 |
34.7 |
25 |
100 ± 15 |
100 ± 15 |
35.8 |
32.8 |
31.25 |
100 ± 15 |
100 ± 15 |
33.9 |
30.9 |
62.5 |
100 ± 15 |
100 ± 15 |
27.8 |
24.8 |
100 |
100 ± 15 |
100 ± 15 |
23.8 |
20.8 |
155 |
100 ± 25 |
100 ± 15 |
19.9 |
16.9 |
200 |
100 ± 25 |
100 ± 15 |
17.7 |
14.7 |
|
Notes (Overall)
Notes: |
Operating temperatures are subject to length de-rating. Cable passes -40C Cold Bend per UL 1581. |
|