商品編號: Belden-9571
Belden-9574, Power-Limited Fire Protective Signaling Circuit Cables NEC Article 760, Type FPLR Awg22, 18, 16 火警警報控制電纜
All cables on this page pass the IEEE 383-2003 Flame Test and are listed by the California State Fire Marshall. Component Recognized UL2464.
Fire Alarm
Power-Limited Fire Protective Signaling Circuit Cables
Subject 1424 (NEC Article 760, Type FPLR)
22 AWG Solid Tinned Copper Conductors • Conductors Cabled
PVC Insulation • Black PVC Jacket
UL AWM Style 2464 & 1424 Tech Info
FAS 105 FT4 Section (300V 105°C) MPR, FPLR Chart 1
Belden-9576 6C
18 AWG Solid Bare Copper Conductors • Conductors Cabled
PVC Insulation • Red PVC Jacket
UL AWM Style 2464 & 1424 FAS 105 FT4 (300V 105°C) MPR, FPLR
Belden-9571 2C
18 AWG Solid Bare Copper Conductors • Conductors Cabled • Overall Beldfoil® Shield (100% Coverage) • 22 AWG Stranded TC Drain Wire
PVC Insulation • Red PVC Jacket
UL AWM Style 2464 & 1424 FAS 105 FT4 (300V 105°C) MPR, FPLR Chart 1
Belden-9574 2C
Belden-9578 4C
16 AWG Solid Bare Copper Conductors • Conductors Cabled
PVC Insulation • Red PVC Jacket
UL AWM Style 2464 & 1424 FAS 105 FT4 (300V 105°C) MPR, FPLR
Belden-9572 2C
16 AWG Solid Bare Copper Conductors • Conductors Cabled • Overall Beldfoil Shield (100% Coverage) • 22 AWG Stranded TC Drain Wire
PVC Insulation • Red PVC Jacket
UL AWM Style 2464 & 1424 FAS 105 FT4 (300V 105°C) MPR, FPLR
Belden-9575 2C FAS 105 FT4 (300V 105°C) MPR, FPLR
UL AWM Style 2464 & 1424
Belden-9579 4C
TC = Tinned Copper
All cables on this page pass the IEEE 383-2003 Flame Test and are listed by the California State Fire Marshall. Component Recognized UL2464.
Introduction
Belden® multi-conductor cables are manufactured in a wide
variety of gage sizes, dimensions, insulation materials, shielding
configurations, and jacketing materials including Plenum and
High-Temperature versions. These cables meet the technical
requirements of many different types of systems. In fact, Belden
offers one of the broadest lines of UL Listed, NEC and CEC
multi-conductor cables available from any single source.
Applications for multi-conductor cables include computers,
communications, instrumentation, sound, control, audio, and
data transmission. Each of these cables is designed to protect
signal integrity under critical conditions by reducing hum, noise,
and crosstalk.
To assist you in selecting the proper cable for your application,
both the suggested working voltages and the maximum temperature
ratings are indicated for each applicable product in this section.
Most of our multi-conductor cables are available from stock. Many
of these are available off the shelf from distributors. If you have a
new or unusual application or you cannot find a multi-conductor
cable in this catalog section that meets your technical requirements,
contact Technical Support at 1-800-BELDEN-1.
Multi-Conductor Cables Packaging
Belden’s unique UnReel® cable dispenser is available for many of
the multi-conductor products listed in this section. The letter “U”
before the specified put-up length denotes UnReel packaging
keywords: Belden-9576, Power-Limited, 火警警報, 控制電纜, 電力限制, 防火, 信號電路, 電纜, Belden9576, Belden9571, Belden9574, Belden9578, Belden9572, Belden9575, Belden9579, MPR, FPLR
|