商品編號: Belden-83753
Belden-83802, Plenum-Rated Fire Alarm Power-Limited Fire Protective Signaling Circuit Cables NEC Article 760, Type FPLP Awg14, 12 鐵氟龍火警警報控制電纜
All cables on this page pass the IEEE 383-2003 Flame Test and are listed by the California State Fire Marshall. Component Recognized UL2464, 300V 80°C.
Plenum-Rated Fire Alarm
Power-Limited Fire Protective, Control and Instrumentation Cables
Subject 1424 (NEC Article 760, Type FPLP)
14 AWG Stranded (7x22) TC Conductors • Conductors Cabled • Overall Beldfoil® (100% Coverage) + TC Braid Shield (85% Coverage)
Plenum • FEP Insulation • Red FEP Jacket
UL Style 2464 & 1424 (300V 200°C) FPLP, CMP FT6
Belden-83752 NEC: 2C
Belden-83753 NEC: 3C
Belden-83754 NEC: 4C
Belden-83756 NEC: 6C
12 AWG Stranded (7x20) TC Conductors • Conductors Cabled • Overall Beldfoil (100% Coverage) + TC Braid Shield (85% Coverage)
Plenum • FEP Insulation • Red FEP Jacket
UL Style 2464 & 1424 (300V 200°C) FPLP, CMP FT6
Belden-83802 NEC: 2C
Belden-83803 NEC: 3C
Belden-83804 NEC: 4C
Belden-83806 NEC: 6C
TC = Tinned Copper
All cables on this page pass the IEEE 383-2003 Flame Test and are listed by the California State Fire Marshall. Component Recognized UL2464, 300V 80°C.
*Capacitance between conductors.
**Capacitance between one conductor and other conductors connected to shield.
† Spools are one piece, but length may vary ±10% from length shown.
Introduction
Belden® multi-conductor cables are manufactured in a wide
variety of gage sizes, dimensions, insulation materials, shielding
configurations, and jacketing materials including Plenum and
High-Temperature versions. These cables meet the technical
requirements of many different types of systems. In fact, Belden
offers one of the broadest lines of UL Listed, NEC and CEC
multi-conductor cables available from any single source.
Applications for multi-conductor cables include computers,
communications, instrumentation, sound, control, audio, and
data transmission. Each of these cables is designed to protect
signal integrity under critical conditions by reducing hum, noise,
and crosstalk.
To assist you in selecting the proper cable for your application,
both the suggested working voltages and the maximum temperature
ratings are indicated for each applicable product in this section.
Most of our multi-conductor cables are available from stock. Many
of these are available off the shelf from distributors. If you have a
new or unusual application or you cannot find a multi-conductor
cable in this catalog section that meets your technical requirements,
contact Technical Support at 1-800-BELDEN-1.
Multi-Conductor Cables Packaging
Belden’s unique UnReel® cable dispenser is available for many of
the multi-conductor products listed in this section. The letter “U”
before the specified put-up length denotes UnReel packaging
keywords: Belden-83752, Plenum-Rated, Fire Alarm, Power-Limited, NEC Article 760, FPLP, 鐵氟龍, 火警警報, 阻燃級, 火災報警, 限功率, 防火信號, 電路電纜, Belden83752, Belden83753, Belden83754, Belden83756, Belden83802, Belden83803, Belden83804, Belden83806, |