商品編號: Belden-5400F1
Belden® -5400F1 Awg20 x 2C Security and Alarm Cable Water-blocked, Shielded Multi-conductor (NEC CM and CEC CM FT1) 可直埋隔離安全監控火災警報用線
Security and Alarm Cable
Water-Blocked for Use in Underground Ducts
Unshielded and Shielded
Water-blocked,
Unshielded Multi-conductor
CM FT1 Rated
Product Description
Tinned copper conductors, PVC insulation, cabled
with overall water-blocking tape, Gray PVC jacket
with rip cord. Sequential footage marking every
two feet.
Water-blocked,
Shielded Multi-conductor
CM FT1 Rated
Product Description
Tinned copper conductors, PVC insulation, cabled
with overall Beldfoil® shield and drain wire, overall
water-blocking tape, Gray PVC jacket with rip cord.
Sequential footage marking every two feet.
Color Code: Black, Red.
Specifications
Conductor Tinned Copper
Insulation PVC
Insulation Thickness .010″ (.254mm)
Shield (where applicable) Beldfoil
Jacket PVC
Approvals
NEC CM
CEC CM FT1
NEC Articles 800
Voltage Rating 300V
Temperature Rating 105°C
Applications
• Security Systems
• Intercom/PA Systems
• Sound/Audio Systems
• Power-Limited Controls
• Indoor or Outdoor Use
5400F1
|
|
Multi-Conductor - Water-Blocked for Use in Underground Ducts - 2 Cond Cabled
20 AWG tinned copper conductors, PVC insulation, cabled with overall water-blocking tape, PVC jacket with ripcord. Sequential footage marking every two feet. |
For more Information
please call
1-800-Belden1 |
Click here for Certificate
Item # |
Putup |
Ship Weight |
Color |
Notes |
Item Desc |
5400F1 0081000 |
1,000 FT |
22.000 LB |
GRAY |
C |
2 #20 S-R PVC FS PVC |
|
Notes: |
|
C = CRATE REEL PUT-UP.
|
Physical Characteristics (Overall)
Conductor
AWG:
# Conductors |
AWG |
Stranding |
Conductor Material |
2 |
20 |
7x28 |
TC - Tinned Copper |
|
Insulation
Insulation Material:
Insulation Material |
Wall Thickness (in.) |
PVC - Polyvinyl Chloride |
.010 |
|
Outer Shield
Outer Shield Material:
Outer Shield Trade Name |
Outer Shield Material |
Beldfoil® |
Aluminum Foil-Polyester Tape |
|
Outer Shield Drain Wire AWG:
Drain Wire Conductor Material |
TC - Tinned Copper |
|
Outer Shield Waterblocking Tape: |
Non-woven waterblocking tape |
Outer Jacket
Outer Jacket Material:
Outer Jacket Material |
Nom. Wall Thickness (in.) |
PVC - Polyvinyl Chloride |
.025 |
|
Outer Jacket Ripcord: |
Yes |
Overall Cable
Overall Cabling Lay Length & Direction:
Overall Nominal Diameter: |
0.206 in. |
Mechanical Characteristics (Overall)
Operating Temperature Range: |
-20°C To +105°C |
Bulk Cable Weight: |
20.200 lbs/1000 ft. |
Max. Recommended Pulling Tension: |
37.100 lbs. |
Min. Bend Radius (Install)/Minor Axis: |
2 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: |
CM |
CEC/C(UL) Specification: |
CM |
EU Directive 2000/53/EC (ELV): |
Yes |
EU Directive 2002/95/EC (RoHS): |
Yes |
EU RoHS Compliance Date (mm/dd/yyyy): |
10/01/2005 |
EU Directive 2002/96/EC (WEEE): |
Yes |
EU Directive 2003/11/EC (BFR): |
Yes |
CA Prop 65 (CJ for Wire & Cable): |
Yes |
MII Order #39 (China RoHS): |
Yes |
Flame Test
UL Flame Test: |
UL1685 UL Loading |
Plenum/Non-Plenum
Electrical Characteristics (Overall)
Nom. Inductance:
Nom. Capacitance Conductor to Conductor:
Nom. Capacitance Cond. to Other Conductor & Shield:
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft) |
10.3 |
|
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/1000 ft) |
11.7 |
|
Max. Operating Voltage - UL:
Max. Recommended Current:
Current |
3.75 Amps per conductor @ 25°C (10°C rise in temp) |
|
|