1. Belden® - Security Solutions (EMEA) 安全監控用線
    Belden-2-hour Fire-resistive Rated Safe-T-Line cables 耐火 防火電線
    Belden-Access Control Composite Cable Line 複合式門禁存取儀控電纜
    Belden-Alarm Security and Speaker Cable
    BeldenBuilding Management Systems and smart homes Cable 智慧型建築物(住宅)監控電纜
    Belden-International Municipal Signal Association (IMSA) Cables 國際城市信號協會(IMSA)認可電纜
    Belden-Waterdog™ Cables可直接埋設防水電纜
    回上一頁
  2. 產品搜尋
    分 類:
    關鍵字:  

    首頁 > > Belden-Alarm Security and Speaker Cable

    Belden® -5400F1 Awg20 x 2C Security and Alarm Cable Water-blocked, Shielded Multi-conductor (NEC CM and CEC CM FT1) 可直埋隔離安全監控火災警報用線
    看原圖
    5515939

    商品編號: Belden-5400F1

    Belden® -5400F1 Awg20 x 2C Security and Alarm Cable Water-blocked, Shielded Multi-conductor (NEC CM and CEC CM FT1) 可直埋隔離安全監控火災警報用線
     

    Security and Alarm Cable
    Water-Blocked for Use in Underground Ducts
    Unshielded and Shielded

    Water-blocked,
    Unshielded Multi-conductor
    CM FT1 Rated


    Product Description
    Tinned copper conductors, PVC insulation, cabled
    with overall water-blocking tape, Gray PVC jacket
    with rip cord. Sequential footage marking every
    two feet.
    Water-blocked,
    Shielded Multi-conductor
    CM FT1 Rated
     

    Product Description
    Tinned copper conductors, PVC insulation, cabled
    with overall Beldfoil® shield and drain wire, overall
    water-blocking tape, Gray PVC jacket with rip cord.
    Sequential footage marking every two feet.
    Color Code: Black, Red.
    Specifications
    Conductor Tinned Copper
    Insulation PVC
    Insulation Thickness .010″ (.254mm)
    Shield (where applicable) Beldfoil
    Jacket PVC
    Approvals
    NEC CM
    CEC CM FT1
    NEC Articles 800
    Voltage Rating 300V
    Temperature Rating 105°C


    Applications
    • Security Systems
    • Intercom/PA Systems
    • Sound/Audio Systems
    • Power-Limited Controls
    • Indoor or Outdoor Use

    5400F1
      Multi-Conductor - Water-Blocked for Use in Underground Ducts - 2 Cond Cabled
    20 AWG tinned copper conductors, PVC insulation, cabled with overall water-blocking tape, PVC jacket with ripcord. Sequential footage marking every two feet.
    For more Information
    please call

    1-800-Belden1

    Click here for Certificate
    Put Ups and Colors:
    Item # Putup Ship Weight Color Notes Item Desc
    5400F1 0081000 1,000 FT 22.000 LB GRAY C 2 #20 S-R PVC FS PVC
    Notes:  
    C = CRATE REEL PUT-UP.
     
    Physical Characteristics (Overall)
    Conductor
    AWG:
    # Conductors AWG Stranding Conductor Material
    2 20 7x28 TC - Tinned Copper
    Insulation
    Insulation Material:
    Insulation Material Wall Thickness (in.)
    PVC - Polyvinyl Chloride .010
    Outer Shield
    Outer Shield Material:
    Outer Shield Trade Name Outer Shield Material
    Beldfoil® Aluminum Foil-Polyester Tape
    Outer Shield Drain Wire AWG:
    Drain Wire Conductor Material
    TC - Tinned Copper
    Outer Shield Waterblocking Tape: Non-woven waterblocking tape
    Outer Jacket
    Outer Jacket Material:
    Outer Jacket Material Nom. Wall Thickness (in.)
    PVC - Polyvinyl Chloride .025
    Outer Jacket Ripcord: Yes
    Overall Cable
    Overall Cabling Lay Length & Direction:
    Length (in.)
    2
    Overall Nominal Diameter: 0.206 in.
    Mechanical Characteristics (Overall)
    Operating Temperature Range: -20°C To +105°C
    Bulk Cable Weight: 20.200 lbs/1000 ft.
    Max. Recommended Pulling Tension: 37.100 lbs.
    Min. Bend Radius (Install)/Minor Axis: 2 in.
    Applicable Specifications and Agency Compliance (Overall)
    Applicable Standards & Environmental Programs
    NEC/(UL) Specification: CM
    CEC/C(UL) Specification: CM
    EU CE Mark: Yes
    EU Directive 2000/53/EC (ELV): Yes
    EU Directive 2002/95/EC (RoHS): Yes
    EU RoHS Compliance Date (mm/dd/yyyy): 10/01/2005
    EU Directive 2002/96/EC (WEEE): Yes
    EU Directive 2003/11/EC (BFR): Yes
    CA Prop 65 (CJ for Wire & Cable): Yes
    MII Order #39 (China RoHS): Yes
    Flame Test
    UL Flame Test: UL1685 UL Loading
    CSA Flame Test: FT1
    Plenum/Non-Plenum
    Plenum (Y/N): No
    Electrical Characteristics (Overall)
    Nom. Inductance:
    Inductance (µH/ft)
    .17
    Nom. Capacitance Conductor to Conductor:
    Capacitance (pF/ft)
    56
    Nom. Capacitance Cond. to Other Conductor & Shield:
    Capacitance (pF/ft)
    101
    Nom. Conductor DC Resistance:
    DCR @ 20°C (Ohm/1000 ft)
    10.3
    Nominal Outer Shield DC Resistance:
    DCR @ 20°C (Ohm/1000 ft)
    11.7
    Max. Operating Voltage - UL:
    Voltage
    300 V RMS
    Max. Recommended Current:
    Current
    3.75 Amps per conductor @ 25°C (10°C rise in temp)