TPE motor supply cable acc. to UL-Std.1277 and UL-Std.2277
Temperature range flexing -40°C bis +105°C
Nominal voltage TC 600 V AWM 1000 V TC Wind Turbine (WTTC) 1000 V
Test voltage 4000 V
Minimum bending radius 7,5 cable Ø
Coupling resistance (-C-type) max. 250 Ohm/km
Cable structure
Bare copper-conductor, fine-wire with AWG dimensions
Core insulation of special PVC with transparent nylon skin
Core identification to DIN VDE 0293 black cores with continuous white numbering
GN-YE conductor in the outer layer
Cores stranded in layers with optimal lay-length
Separator
Outer sheath of special TPE
Sheath colour orange (RAL 2003)
with length marking in feet
C-Type Screening with braid of tinned copper wires, optimal coverage, approx. 85%
Properties
self-extinguishing and flame retardant acc. to CSA FT4
The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers
Tests
UL: TC-ER, WTTC, MTW, NFPA 79 2012, UL AWM 105°C, OIL RES I & II, 75° C wet Bus Drop Cable, Class 1 Div. 2 per NEC Art. 336, 318, 501
CSA: c (UL) CIC-TC FT4, AWM I/II A/B FT4
Note
HDP = Heavy Duty Power
Application
HELUKABEL® TRAYCONTROL® 670 HDP / 670-C-HDP are multi-conductor severe duty motor supply cables with Bus Drop, TC-ER and CIC/TC approval. Superior oil performance for long cable life and permitted to be used in hazardous (classified) locations Class I Div 2 per NEC 336, 318 and 501. Special extruded sheath and fine copper stranding approved for exposed run, pipes and burial installation. Excellent flexibility and easier to pull than standard tray cables. Suitable for installation in the open unprotected installation on cable tray and from cable tray to machines according to NFPA 79 edition 2012. Recommended Applications: Motor connections in industrial and automation environments, machine tool, automotive and renewable energies. CE = The product is conformed with the EC Low-Voltage Directive 2006/95/EC.
★★★★使用操作說明★★★★
TRAYCONTROL® 670-C HDP
Technical data
TPE motor supply cable acc. to UL-Std.1277 and UL-Std.2277
Temperature range flexing -40°C bis +105°C
Nominal voltage TC 600 V AWM 1000 V TC Wind Turbine (WTTC) 1000 V
Test voltage 4000 V
Minimum bending radius 7,5 cable Ø
Coupling resistance (-C-type) max. 250 Ohm/km
Cable structure
Bare copper-conductor, fine-wire with AWG dimensions
Core insulation of special PVC with transparent nylon skin
Core identification to DIN VDE 0293 black cores with continuous white numbering
GN-YE conductor in the outer layer
Cores stranded in layers with optimal lay-length
Separator
Outer sheath of special TPE
Sheath colour orange (RAL 2003)
with length marking in feet
C-Type Screening with braid of tinned copper wires, optimal coverage, approx. 85%
Properties
self-extinguishing and flame retardant acc. to CSA FT4
The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers
Tests
UL: TC-ER, WTTC, MTW, NFPA 79 2012, UL AWM 105°C, OIL RES I & II, 75° C wet Bus Drop Cable, Class 1 Div. 2 per NEC Art. 336, 318, 501