Rubber sheathed cable H07RN-F to DIN VDE 0285-525-2-21, BS 7919 DIN EN 50525-2-21, IEC 60245-4
Temperature range -30°C to +60°C
Permissible operating temperature at conductor +60°C
Nominal voltage U0/U 450/750 V in case of protected and fixed installation U0/U 600/1000 V
Max. permissible operating voltage in three phase and one phase a.c. system U0/U 476/825 V direct current-system U0/U 619/1238 V
Test voltage 2500 V
Permanent tensile load max. 15 N/mm²
Minimum bending radius for fixed installation 4x cable Ø for guiding over roller 7,5x cable Ø during winding on drums 5x cable Ø
Cable structure
Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5
Core insulation of rubber EI4 to DIN VDE 0207-363-1 / DIN EN 50363-1
Core identification to DIN VDE 0293-308 - up to 5 cores coloured - from 6 cores, black with continuous white numbering
GN-YE conductor, 3 cores and above
Cores stranded in layers with optimal lay-length
Outer sheath of rubber EM2 to DIN VDE 0207-363-2-1/DIN EN 50363-2-1
Sheath colour black
Properties
Resistant to
Weather
Tests
Behaviour in fire to DIN VDE 0482-332-1-2 DIN EN 60332-2-1, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)
Ozone resistant of the insulation to DIN VDE 0472 part 805, test method A or part 805 A1, test method C
Oil resistant test according to DIN VDE 0473-811-404,DIN EN 60811-404
Note
G = with green-yellow conductor x = without green-yellow conductor
AWG sizes are approximate equivalent values. The actual cross-section is in mm².
The core identification of a single core sheathed, of an insulated wire is black.
Application
Heavy duty rubber-sheathed flexible cables are suited for use for medium mechanical stress in dry, damp and wet areas as well as in open air and in agriculture plants. They are used for equipment in industry works such as boilers, heating plates, hand lamps, electric tools such as drills, circular saws and homework tools as well as for transportable motors or machines at site. These cables are also suitable for fixed installation on plaster, in temporary buildings and residential barracks. They are suitable for direct laying on components and mechanical parts of machines, for example lifts and cranes. They can be used in case of protected and fixed installation in tubes or in equipment as well as rotor connecting cable of motors with a working voltage up to 1000 V alternating voltage or a direct voltage up to 750 V against ground. The operating direct voltage is permitted up to 900 V against ground when they are used in rail-coaches. Installation in hazardous areas according to DIN VDE 0165 is allowed. CE = The product is conformed with the EC Low-Voltage Directive 2006/95/EC.