Special PVC cable with increased heat-resistance adapted to DIN VDE 0285-525-2-11 / DIN EN 50525-2-11 0,5-0,75 mm² acc. to IEC 60227/56 1,0-2,5 mm² acc. to IEC 60227/57
Temperature range flexing -5°C to +105°C fixed installation -30°C to +105°C (for short time +120°C)
Nominal voltage 0,5-1 mm² U0/U 300/500 V from 1,5 mm² U0/U 450/750 V
Radiation resistance up to 80x106 cJ/kg (up to 80 Mrad)
Cable structure
Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5
Core insualtion of special PVC compound type TI3 to DIN VDE 0207-363-3 / DIN EN 50363-3
Core identification to DIN VDE 0293-308 - up to 5 cores coloured - from 6 cores, black with continuous white numbering
GN-YE conductor, 3 cores and above in the outer layer
Cores stranded in layers with optimal lay-length
Outer sheath of special PVC, heat- resistant compound type TM3 to DIN VDE 0207-363-4-1/DIN EN 50363-4-1
Outer sheath black (RAL 9005), also available in other colours on request
with meter marking
Properties
The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers
Tests
PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)
Note
G = with green-yellow conductor x = without green-yellow conductor
AWG sizes are approximate equivalent values. The actual cross-section is in mm².
Therm cables are ideal for use in machines, appliances or motors which are subject to direct contact with high temperatures (e. g. varnishing machines and drying towers etc.). For application in dry, moist and wet rooms and in open air. CE = The product is conformed with the EC Low-Voltage Directive 2006/95/EC.