1. HELUKABEL-Industrial All-Weather & Rubber Cables
    HELUKABEL-Industrial Trailing Cables 拖曳電纜
    HELUKABEL-Industrial Heat-Resistant Cables
    HELUKABEL-Industrial Motor Servo & Feedback Cables
    HELUKABEL-Industrial PUR UL/CSA Control Cables
    HELUKABEL-Industrial PVC UL/CSA Control Cables
    HELUKABEL-Industrial UL/CSA Data Cables
    HELUKABEL-Industrial UL/CSA Drag Chain Cables
    HELUKABEL-Infrastructure Security Cables
    HELUKABEL-Shipwiring & Marine Cables 船舶電纜
    HELUKABEL-Single Conductors
    回上一頁
  2. 產品搜尋
    分 類:
    關鍵字:  

    首頁 > > HELUKABEL-Infrastructure Security Cables

    N2XH power cable, 0,6/1 kV, halogen-free, without functionality
    看原圖
    30169544




    商品編號: HELUKABEL-N2XH

    N2XH power cable, 0,6/1 kV, halogen-free, without functionality



    ★★★★商品說明★★★★

    Technical data
    • Power and control cable acc. to
      DIN VDE 0276 part 604,
      HD 604 S1 part 1 and part 5G
    • Temperature range
      during installation -5°C to +50°C
      fixed installation -30°C to +90°C
    • Permissible operating temperature
      at conductor +90°C
    • Nominal voltage U0/U 0,6/1 kV
    • Test voltage 4 kV
    • Minimum bending radius
      single-core 15x cable Ø
      multi-core 12x cable Ø
    • Radiation resistance
      up to 100x106 cJ/kg (up to 100 Mrad)
    • Caloric load values
      see Technical Informations
    Cable structure
    • Bare copper-conductor, to
      DIN VDE 0295 cl.1 or cl.2, single-wire
      or multi-wire, BS 6360 cl.1 or cl.2,
      IEC 60228 cl.1 or cl.2
    • Core insulation of cross-linked
      polyethylene (XLPE)
      compound type 2XI1 to HD 604 S1
    • Core identification to DIN VDE 0293-308
    • Core identification for 3+½ conductor
      J-type: GN-YE (½), BN, BK, GY
      O-type: BU (½), BN, BK, GY
    • Cores stranded in layers
      (for multi-core cables)
    • Overall filled inner sheath
    • Covered by filling compound or taping
    • Outer sheath of thermoplastic
      polyolefine, compound type HM4
      to HD 604 S1
    • Sheath colour black
    Properties
    • Halogen-free, no separation of corrosive
      or toxic gases
    • Limited propagation of fire
    • Low smoke development
    • The materials used in manufacture are
      cadmium-free and contain no silicone
      and free from substances harmful to
      the wetting properties of lacquers
    Tests
    • Flame test acc. to DIN VDE 0482-332-3-24,
      BS 4066 part 3, DIN EN 60332-3-24,
      IEC 60332-3-24 (previously DIN VDE 0472
      part 804 test method C)
    • Corrosiveness of combustion gases
      acc. to DIN VDE 0482 part 267,
      DIN EN 50267-2-2, IEC 60754-2
      (equivalent DIN VDE 0472 part 813)
    • Halogen-free acc. to DIN VDE 0482
      part 267, DIN EN 50267-2-1, IEC 60754-1
      (equivalent DIN VDE 0472 part 815)
    • Smoke density acc. to DIN VDE 0482
      part 1034-1+2, DIN EN 61034-1+2,
      IEC 61034-1+2, BS 7622 part 1+2
      (previously DIN VDE 0472 part 816)
    Note
    • re = round conductor, single-wire
      rm = round conductor, multi-wire
      sm = sectional conductor, mutli-wire
    • J-version = with GN-YE conductor
      O-version = without GN-YE conductor
    • AWG sizes are approximate equivalent
      values. The actual cross-section is in mm².
    • LS0H = Low Smoke Zero Halogen
    Application

    Halogen-free power cables with enhanced characteristics in case of fire are used for applications where harm to human life and damage to property must be prevented in the event of fire, e. g. in power stations, industrial installations, communal establishments, hotels, airports, underground stations, railway stations, hospitals department stores, banks, schools theaters, multi-storey buildings, process control centres etc. Suitable for fixed installation in dry, damp or wet environments, in, above, on and beneath plaster as well as in masonary walls and in concrete. These cables are suitable for outdoor applications and in underground by using in conduits or tubes. For the installation in conduit all precautions must be taken that no accumulation of water can occur in the pipes.
    CE = The product is conformed with the EC Low-Voltage Directive 2006/95/EC.



    ★★★★商品規格描述★★★★

    Part no.

    No.cores x
    cross-sec.
    mm²

    Outer Ø

    app. mm

    Cop.
    weight

    kg / km

    Weight

    app. kg / km

    AWG-No.

    J type

    O type

    53136

    53330

    3 x 50 / 25   sm

    28,5

    1680,0

    2100,0

    1

    53137

    53331

    3 x 70 / 35   sm

    31,4

    2352,0

    2800,0

    2/0

    53138

    53332

    3 x 95 / 50   sm

    34,9

    3216,0

    3750,0

    3/0

    53139

    53333

    3 x 120 / 70   sm

    38,0

    4128,0

    4750,0

    4/0

    53140

    53334

    3 x 150 / 70   sm

    43,3

    4992,0

    5750,0

    300 kcmil

    53141

    53335

    3 x 185 / 95   sm

    47,2

    6240,0

    7200,0

    350 kcmil

    53142

    53336

    3 x 240 / 120   sm

    53,4

    8064,0

    9300,0

    500 kcmil