A- PRYSMIAN CABLES & SYSTEMS EPROTENAX EPR/High-strength Airbag layer/PVC MV-105 ICEA S-93-639 (WC74)and UL 1072 CT 105°C, 15KV 3芯耐高壓AirGuard控制電纜
For installations in both exposed and concealed locations in accordance with NEC. For installation in wet and dry locations in accordance with NEC. May be directly buried or embedded in concrete. For installation on cable trays, troughs, metal racks, aerial installation and continuous rigid cable supports in accordance with NEC. Suitable for vertical riser applications. Suitable for Class I Division 2 locations. |
| |
| | |
玉山 / 台新 / 華南 / 萬泰 / 兆豐 / 遠東 / 新光 / 永豐 / 第一 / 彰化 / 合庫 / 日盛 / 匯豐 / 渣打國泰世華 / 台北富邦 / 大眾銀行 / 台灣中小企銀/台中商銀 / 澳盛銀行
| |
| | |
| | Armored Cable AirGuard 15KV PRYSMIAN CABLES & SYSTEMS EPR insulation High strength Airbag layer PVC jacket SPECIFICATIONS 1. CONDUCTOR: Class B Compact concentric strand soft drawn annealed copper per ASTM 2. CONDUCTOR SHIELD: Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation 3. INSULATION:Natural high dielectric strength EPROTENAX EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life 4. METALLIC SHIELD: Helically applied non-magnetic copper tape(s) over insulation shield with a minimum overlap of 15%. A aluminum/polyester ribbon is longitudinally applied under the copper tape shield for phase identification - one conductor with red, one conductor with blue, and one conductor with black 5. GROUNDING CONDUCTORS:Bare stranded copper conductor, one in each interstice, per UL, ICEA and ASTM 6. ASSEMBLY: Phase identified shielded conductors cabled with fillers and grounding conductor (as specified), forming a firm and cylindrical cable core. A binder tape is applied to maintain core symmetry and mechanical stability 7. MECHANICAL PROTECTION: High-strength and high-crush-resistant Airbag layer extruded cover the core assembly 8. CHEMICAL PROTECTION:A layer of Drylam which consists of aluminum tape and a chemical-resistant extruded polymer layer is applied 9. JACKET: Sunlight-resistant Polyvinyl Chloride (PVC) jacket 10.STANDARDS:Listed Type MV-105 per UL 1072 and MSHA Type MP, meets ICEA S-93-639 (WC74) requirements. Identified for CT use. Cable passes IEEE 1202/FT4 (70,000 Btu/hr) and ICEA T-29-520 (210,000 Btu/hr) flame tests 11.AMPACITY:Based on an ambient temperature of 40°C, cable isolated in air per 2008 NEC table 310.71 12.TEMPERATURE: 105°C 13.VOLTAGE: 15 kV APPLICATIONS For installations in both exposed and concealed locations in accordance with NEC. For installation in wet and dry locations in accordance with NEC. May be directly buried or embedded in concrete. For installation on cable trays, troughs, metal racks, aerial installation and continuous rigid cable supports in accordance with NEC. Suitable for vertical riser applications. Suitable for Class I Division 2 locations. AIRGUARD 15 KV, UL TYPE MV-105 |
| |
|
|