    A-NORTECK  XLP/Aluminum Armor/PVC 90ºC, UL and CSA 600 V Multiconductor 多芯波浪狀鋁管鎧裝控制電纜
    看原圖
    5259001




    商品編號: A-7XD-1402AJ

    A-NORTECK XLP/Aluminum Armor/PVC 90ºC, UL and CSA 600 V Multiconductor 多芯波浪狀鋁管鎧裝控制電纜


    For use in control circuits in industrial plants,commercial buildings, and central and substationutility applications. May be installed intrays, racks, hangers, etc., eliminating the needfor conduit. Suitable for indoor and outdoor installation.



    ★★★★商品說明★★★★

    600V MULTI CONDUCTOR
    Aluminum Armor
    XLP Insulation
    Inner and Outer PVC Jackets
    90°C, UL & CSA 600V


    APPLICATIONS:
    For use in control circuits in industrial plants,commercial buildings, and central and substation
    utility applications. May be installed intrays, racks, hangers, etc., eliminating the need
    for conduit. Suitable for indoor and outdoor installation.


    SPECIFICATIONS:
    1. CONDUCTOR: Class B stranded, bare, annealed copper per ASTM B-3, B-8.
    2. INSULATION: Cross-linked polyethylene (XLP) per ICEA S-73-532 (NEMA WC57), Type
    XHHW-2 requirements of UL and RW90 requirements of CSA. Color coding is Method 1,
    Table E-2 (formerly K-2) (2 & 3 conductors) or Method 4 (4 or more conductors).
    3. ASSEMBLY: The insulated conductors are cabled with a single UL, uninsulated ground wire and
    fillers to make round.
    4. INNER JACKET: Black, sunlight resistant polyvinyl chloride (PVC) applied per ICEA.
    Jacket is low acid gas per CSA C22.2 No. 0.3.
    5. ARMOR: An aluminum interlocked armor is applied overall in accordance with UL 1569,
    ICEA and CSA.
    6. OVERALL JACKET: Black, sunlight resistant polyvinyl chloride (PVC) applied overall per
    ICEA. Jacket is low acid gas per CSA C22.2 No. 0.3.
    7. STANDARDS: Cables meet UL, IEEE 383 and FT-4 70,000 BTU flame tests, and are
    marked “FOR CT USE.’’ Also meets ICEA T-29-520 210,000 BTU flame test. Meets CSA
    –40°C cold impact and bend. Individual conductors and completed cables are tested
    in accordance with UL requirements for Type MC cables and CSA requirements
    for Type TECK cables.
    8. AMPACITY: Based on not more than three conductors in raceway or cable or earth
    and an ambient temperature of 30°C per NEC 310-16. Values have been derated
    for more than three conductors in accordance with the NEC.
    9. TEMPERATURE: 90°C
    10. VOLTAGE: UL & CSA 600 Volts