1. An-Armor Cable Teck 90 & Accessories 金屬鎧裝電纜
    An-Armor Cable 1 金屬鎧裝電纜
    An-BuildingWire(建築線)
    An-Crane Festoon and Reeling Cable
    An-INDUSTRIAL TRAY CABLE (TC)
    An-Instrumentation & Tray Cable [ Industrial / Special Applications Cables - 150°C to 260°C ]
    An-Instrumentation Cable 儀俵控制電纜
    An-MINING CABLE(Thermoset Jacket)採礦業機械馬達用線(軟質)
    An-Portable Cord 輕便電纜
    An-Power Cable1 電力電纜
    An-Power Cable2 電力電纜
    An-Power Cable3 電力電纜
    An-PVC-Nylon/PVC Control Cable PVC尼龍被覆控制電纜-1
    An-PVC-Nylon/PVC Control Cable PVC尼龍被覆控制電纜-2
    An-PVC-Nylon/PVC Shielded Control Cable PVC尼龍被覆鋁箔隔離控制電纜
    An-PVC-Nylon/PVC-Nylon Control Cable PVC尼龍絕緣PVC尼龍被覆控制電纜
    An-Security Low-voltage Cable 低壓安全監控用線
    An-TRAFFIC SIGNAL CABLE 交通號誌控制電纜
    回上一頁
  2. 產品搜尋
    分 類:
    關鍵字:  

    首頁 > > An-Armor Cable 1 金屬鎧裝電纜

    A-EPR/ Aluminum Armor/PVC UL 90°C, 15KV 3C 133% Insulation Level SHIELDED (CCW) Armored Cable耐高壓波紋鋁管鎧裝3芯電力控制電纜
    看原圖
    5260298




    商品編號: A-7Y-0203

    A-EPR/ Aluminum Armor/PVC UL 90°C, 15KV 3C 133% Insulation Level SHIELDED (CCW) Armored Cable耐高壓波紋鋁管鎧裝3芯電力控制電纜


    Primary power and lighting circuits in manufacturingand processing plants, feeders in industrial andcommercial distribution systems, power supply tostation auxiliaries in electric power stations andsubstations. May be used in wet or dry locationsinstalled in open tray, trough or ladder.



    ★★★★商品說明★★★★

    Armored Cable
    Continuous Corrugated Weld

    15 kV Three Conductor 133% Insulation Level

    Continuous aluminum armor
    Shielded
    EPR insulation


    SPECIFICATIONS
    1. CONDUCTOR:
    Class B stranded, bare, annealed copper per ASTM B3 and B8, strand shield is an extruded semiconducting material
    2. INSULATION: Ethylene Propylene Rubber (EPR) per ICEA S-93-639 (NEMA WC74)
    3. SHIELD:An extruded semiconducting insulation shield and then an uncoated 5-mil copper tape with 25% overlap is helically applied over the semiconducting layer
    4. ASSEMBLY: The three-phase conductors are cabled with a Class B stranded ground wire and fillers to make round, a binder tape is applied overall
    5. ARMOR: An impervious, corrugated continuous seam-welded aluminum alloy sheath in accordance with UL 1569, armor is pressure-tested and meets the grounding
    requirements of NEC Article 250
    6. OVERALL JACKET: Red, sunlight-resistant Polyvinyl Chloride (PVC)
    7. STANDARDS:Cable shall be tested in accordance with UL 1072 requirements for Type MV-105, UL 2205 for Type MC-HL and ICEA S-93-639 (NEMA WC74). Cables meet the
    UL 1685 and IEEE 1202/FT4 70,000 Btu/hr and the ICEA T-29-520 210,000 Btu/hr vertical tray flame tests and are marked "for CT use". Cable meets AEIC CS-8 qualification
    testing requirements
    8. AMPACITY: Based on a three-conductor cable isolated in air with a conductor temperature of 90°C and an ambient temperature of 40°C per NEC 310.71
    9. TEMPERATURE: 90°C
    10.VOLTAGE: 15 kV


    APPLICATIONS
    Primary power and lighting circuits in manufacturing and processing plants, feeders in industrial and commercial distribution systems, power supply to station auxiliaries in
    electric power stations and substations. May be used in wet or dry locations installed in open tray, trough or ladder.