1. An-Armor Cable Teck 90 & Accessories 金屬鎧裝電纜
    An-Armor Cable 1 金屬鎧裝電纜
    An-BuildingWire(建築線)
    An-Crane Festoon and Reeling Cable
    An-INDUSTRIAL TRAY CABLE (TC)
    An-Instrumentation & Tray Cable [ Industrial / Special Applications Cables - 150°C to 260°C ]
    An-Instrumentation Cable 儀俵控制電纜
    An-MINING CABLE(Thermoset Jacket)採礦業機械馬達用線(軟質)
    An-Portable Cord 輕便電纜
    An-Power Cable1 電力電纜
    An-Power Cable2 電力電纜
    An-Power Cable3 電力電纜
    An-PVC-Nylon/PVC Control Cable PVC尼龍被覆控制電纜-1
    An-PVC-Nylon/PVC Control Cable PVC尼龍被覆控制電纜-2
    An-PVC-Nylon/PVC Shielded Control Cable PVC尼龍被覆鋁箔隔離控制電纜
    An-PVC-Nylon/PVC-Nylon Control Cable PVC尼龍絕緣PVC尼龍被覆控制電纜
    An-Security Low-voltage Cable 低壓安全監控用線
    An-TRAFFIC SIGNAL CABLE 交通號誌控制電纜
    回上一頁
  2. 產品搜尋
    分 類:
    關鍵字:  

    首頁 > > An-BuildingWire(建築線)

    A-Building Wire  TFN AND TFFN  PVC/Nylon Jacket  90°C, 600 Volts PVC尼龍被覆電線(抗油汙, 化學品 耐磨損)
    看原圖
    5260438

    商品編號: A-6F-1801

    A-Building Wire TFN AND TFFN PVC/Nylon Jacket 90°C, 600 Volts PVC尼龍被覆電線(抗油汙, 化學品 耐磨損)

     

    Building Wire
    PVC

    TFN and TFFN

    Fixture wire
    Solid or stranded
    PVC insulation
    Nylon jacket
    90°C, 600 V


    SPECIFICATIONS
    1. CONDUCTOR:
    Stranded, annealed copper per ASTM B-3
    2. INSULATION: Polyvinyl Chloride (PVC)
    3. OVERALL JACKET: Nylon
    4. STANDARDS:Meets requirements of UL 66 for Type TFN or TFFN fixture wire
    5. AMPACITY: Based on Table 402.5 of the 2008 NEC
    6. TEMPERATURE: 90°C
    7. VOLTAGE:600 V


    APPLICATIONS
    These wires are recommended in most types of industrial and commercial applications where resistance to mechanical abuse is required. The nylon jacket has excellent
    resistance to abrasion, chemicals, gas and oil.

      Fixture Wire
    Solid or Stranded
    PVC Insulation
    Nylon Jacket
    90°C, 600 Volts

     


    APPLICATIONS:
    These wires are recommended in most types of
    industrial and commercial applications where
    resistance to mechanical abuse is required. The
    nylon jacket has excellent resistance to abrasion,
    chemicals, gas and oil.
     

    SPECIFICATIONS:
    1. CONDUCTOR:
    Stranded, annealed copper per ASTM B-3, B-174 and UL 62.
    2. INSULATION: Polyvinyl chloride (PVC) per UL 62.
    3. OVERALL JACKET: Nylon per UL 62.
    4. STANDARDS: Meets requirements of UL for Type TFN or TFFN fixture wire.
    5. AMPACITY: Based on Table 402-5 of the NEC.
    6. TEMPERATURE: 90°C
    7. VOLTAGE: 600 Volts


     
     
     
     

    TFN AND TFFN