1. An-Armor Cable Teck 90 & Accessories 金屬鎧裝電纜
    An-Armor Cable 1 金屬鎧裝電纜
    An-BuildingWire(建築線)
    An-Crane Festoon and Reeling Cable
    An-INDUSTRIAL TRAY CABLE (TC)
    An-Instrumentation & Tray Cable [ Industrial / Special Applications Cables - 150°C to 260°C ]
    An-Instrumentation Cable 儀俵控制電纜
    An-MINING CABLE(Thermoset Jacket)採礦業機械馬達用線(軟質)
    An-Portable Cord 輕便電纜
    An-Power Cable1 電力電纜
    An-Power Cable2 電力電纜
    An-Power Cable3 電力電纜
    An-PVC-Nylon/PVC Control Cable PVC尼龍被覆控制電纜-1
    An-PVC-Nylon/PVC Control Cable PVC尼龍被覆控制電纜-2
    An-PVC-Nylon/PVC Shielded Control Cable PVC尼龍被覆鋁箔隔離控制電纜
    An-PVC-Nylon/PVC-Nylon Control Cable PVC尼龍絕緣PVC尼龍被覆控制電纜
    An-Security Low-voltage Cable 低壓安全監控用線
    An-TRAFFIC SIGNAL CABLE 交通號誌控制電纜
    回上一頁
  2. 產品搜尋
    分 類:
    關鍵字:  

    首頁 > > An-MINING CABLE(Thermoset Jacket)採礦業機械馬達用線(軟質)

    ANIXT-LEAD-CURED-TypeW-FLAT Heavy Duty EPR/Thermoset Jacket 90°C, 600/2000 Volts EPR扁平橡膠熱固熔機械馬達礦場用線 (軟質移動型)
    看原圖
    5270825




    商品編號: ANIXT-LEAD-CURED-TypeW-FLAT

    ANIXT-LEAD-CURED-TypeW-FLAT Heavy Duty EPR/Thermoset Jacket 90°C, 600/2000 Volts EPR扁平橡膠熱固熔機械馬達礦場用線 (軟質移動型)


    For use as portable trailing cable on DC shuttle carsand other mobile mining equipment such as cuttingor loading machines and drills, where grounding isnot required and where the cable must withstandconstant flexing and reeling.



    ★★★★商品說明★★★★

    TYPE W-FLAT
    LEAD CURED
    Heavy Duty
    EPR Insulation
    Thermoset Jacket
    90°C, 600/2000 Volts
     

    APPLICATIONS:
    For use as portable trailing cable on DC shuttle cars
    and other mobile mining equipment such as cutting
    or loading machines and drills, where grounding is
    not required and where the cable must withstand
    constant flexing and reeling.
     

    SPECIFICATIONS:
    1. CONDUCTOR:
    Rope-stranded, tinned copper per ASTM B-172.
    2. INSULATION: Ethylene propylene rubber (EPR).
    3. COLOR CODE: Black, White.
    4. ASSEMBLY: The specified number of conductors cabled with fillers, over-wrapped with
    reinforced binder, separator where applicable.
    5. OVERALL JACKET: Lead-cured thermoset compound.
    6. STANDARDS: Meets the requirements of ICEA S-75-381 (NEMA WC58). Accepted by
    MSHA, and marked with the manufacturer’s P number.
    7. AMPACITY: Based on an ambient temperature of 40°C per ICEA S-75-381, Table H-1.
    8. TEMPERATURE: 90°C
    9. VOLTAGE: 600/2000 Volts