    A-XLP/TS-CPE UL Listed Type TC 90°C, 600 V Multiconductor Power Cable 多芯防曬可直接埋設電力電纜線
    看原圖
    5639923




    商品編號: A-3RH-1003

    A-XLP/TS-CPE UL Listed Type TC 90°C, 600 V Multiconductor Power Cable 多芯防曬可直接埋設電力電纜線


    Used for control and power applications in chemical plants, steel mills, industrial plants, utility substations and generating stations, residential and commercial buildings.
    May be used in Class 1, Div. 2 Hazardous Locations per NEC Art. 501. These cables also conform to Art. 392 "Cable Trays" and Art. 336 "Power and Control Tray Cable."
    Suitable for aerial, duct or direct burial.




    ★★★★商品說明★★★★

    Power Cable
    600 V Multiconductor

    XLP/TS-CPE

    XLP insulation
    TS-CPE jacket
    UL Listed Type TC
    90°C, 600 V
     

    SPECIFICATIONS
    1. CONDUCTOR:
    Class B stranded, tinned copper per ASTM B-3 and B-8
    2. INSULATION: Cross-Linked Polyethylene (XLP), per ICEA S-95-658 (NEMA WC70), meets UL requirements for Type XHHW-2
    3. COLOR CODE: Conductors are coded per ICEA Method 4 (printed numbers)
    4. ASSEMBLY: Insulated conductors together with one bare UL ground wire, cabled together with suitable fillers and wrapped with a clear aluminum/polyester tape
    5. OVERALL JACKET: Sunlight-resistant thermoset Chlorinated Polyethylene (TS-CPE)
    6. STANDARDS: Meets UL 1277 requirements for Type TC cables having VW-1 rated XHHW-2 conductors. Cables are listed for direct burial and meet the IEEE 1202, IEEE 383, and
    UL 1685, 70,000 Btu/hr flame tests as well as the ICEA T-29-520, 210,000 Btu/hr flame test
    7. AMPACITY: Based on not more than three conductors in raceway or cable or earth per NEC Table 310.16 with an ambient temperature of 30°C and a conductor temperature of
    90°C. All 4-conductor values have been derated per 2008 NEC Table 310.15(B)(2)(a)
    8. TEMPERATURE:90°C
    9. VOLTAGE: 600 V


    APPLICATIONS
    Used for control and power applications in chemical plants, steel mills, industrial plants, utility substations and generating stations, residential and commercial buildings.
    May be used in Class 1, Div. 2 Hazardous Locations per NEC Art. 501. These cables also conform to Art. 392 "Cable Trays" and Art. 336 "Power and Control Tray Cable."
    Suitable for aerial, duct or direct burial.