Security Low-voltage Cable
Belden New Generation
1.NPLF Fire Alarm Shielded
SPECIFICATIONS
1. CONDUCTOR: Solid bare copper
2. INSULATION: Nylon/polyvinyl chloride (PVC)
3. SHIELDING:Beldfoil shield with drain wire
4. JACKET:Red polyvinyl chloride (PVC)
5. STANDARDS:NEC: NPLF, UL Listed
6. TEMPERATURE: 75°C
APPLICATIONS
Non-power limiting (NPLF) fire alarm cable.
2. FPLR-CIC Fire Alarm Unshielded
Circuit Integrity cable for in-conduit applications. Two hour rated fire alarm, notification devices, signaling,
fire protective circuits. Two-hour in-conduit cables for survivability requirements according to NFPA101.
Zero halogen cables.
SPECIFICATIONS
1. Article 760 of NEC for Fire Alarm Circuit Integrity (CI). NEC-FPLR. UL Standard 2196
2. CONDUCTOR: Bare copper solid conductors
3. INSULATION: Thermoset elastomer insulation
4. JACKET:Red polyolefin (PO)
5. STANDARDS: NEC: FPLR, UL Listed. UL 2196 for Circuit Integrity in conduit, UL Electrical Circuit Protective Systems FHIT #30
3. FPLR-CIC Fire Alarm Shielded
Circuit Integrity cable for in-conduit applications. Fire alarm, notification devices, signaling, fire
protective circuits. Two-hour direct flame cables for survivability requirements according to NFPA101.
Zero halogen cables.
SPECIFICATIONS
1. Article 760 of NEC for Fire Alarm Circuit Integrity (CI) in conduit. NEC-FPLR. UL Standard 2196
2. CONDUCTOR: Bare copper stranded and solid conductors
3. INSULATION:Thermoset elastomer insulation
4. SHIELDING: Corrosion-resistant Beldfoil shield, 100 percent coverage with tinned copper drain wire
5. JACKET: Red polyolefin (PO)
6. STANDARDS: NEC: FPLR, UL Listed. UL Electrical Circuit Protective Systems FHIT #30
4. FPLR-CI Fire Alarm Unshielded
SPECIFICATIONS
1. Article 760 of NEC for Fire Alarm Circuit Integrity (CI). NEC-FPLR. UL Standard 2196
2. CONDUCTOR: Bare copper solid conductors
3. INSULATION:Thermoset elastomer insulation
4. JACKET: Red polyolefin (PO)
5. STANDARDS: NEC: FPLR, UL Listed. UL 2196 for Circuit Integrity in conduit, UL Electrical Circuit Protective Systems FHIT #30
5. FPLR-CI Fire Alarm Shielded
Circuit Integrity cable for riser applications, non-conduit and nonplenum. Fire alarm, notification
devices, signaling, fire protective circuits. Two-hour direct flame cables for survivability
requirements according to NFPA101. Zero halogen cables.
SPECIFICATIONS
1. Article 760 of NEC for Fire Alarm Circuit Integrity (CI). NEC-FPLR-CI. UL Standard 2196
2. CONDUCTOR:Bare copper stranded and solid conductors
3. INSULATION:Thermoset elastomer insulation
4. SHIELDING: Corrosion-resistant Beldfoil shield 100 percent coverage with tinned copper drain wire
5. JACKET: Red polyolefin (PO)
6. STANDARDS: NEC: FPLR-CI, UL Listed