    Belden-NPLF, FPLR-CIC Fire Alarm Security Low-voltage Cable 低壓 火警警報通信安全監控電纜線
    看原圖
    5637990




    商品編號: Belden-5020FN

    Belden-NPLF, FPLR-CIC Fire Alarm Security Low-voltage Cable 低壓 火警警報通信安全監控電纜線


    Circuit Integrity cable for in-conduit applications. Two hour rated fire alarm, notification devices, signaling, fire protectivecircuits. Two-hour in-conduit cables for survivability requirements according to NFPA101. Zero halogen cables.



    ★★★★商品說明★★★★

    Security Low-voltage Cable
    Belden New Generation

    1.NPLF Fire Alarm Shielded

    SPECIFICATIONS
    1. CONDUCTOR:
    Solid bare copper
    2. INSULATION: Nylon/polyvinyl chloride (PVC)
    3. SHIELDING:Beldfoil shield with drain wire
    4. JACKET:Red polyvinyl chloride (PVC)
    5. STANDARDS:NEC: NPLF, UL Listed
    6. TEMPERATURE: 75°C
     

    APPLICATIONS
    Non-power limiting (NPLF) fire alarm cable.

    2. FPLR-CIC Fire Alarm Unshielded

    Circuit Integrity cable for in-conduit applications. Two hour rated fire alarm, notification devices, signaling,
    fire protective circuits. Two-hour in-conduit cables for survivability requirements according to NFPA101.
    Zero halogen cables.
     

    SPECIFICATIONS
    1. Article 760 of NEC for Fire Alarm Circuit Integrity (CI). NEC-FPLR. UL Standard 2196
    2. CONDUCTOR: Bare copper solid conductors
    3. INSULATION: Thermoset elastomer insulation
    4. JACKET:Red polyolefin (PO)
    5. STANDARDS: NEC: FPLR, UL Listed. UL 2196 for Circuit Integrity in conduit, UL Electrical Circuit Protective Systems FHIT #30

    3. FPLR-CIC Fire Alarm Shielded

    Circuit Integrity cable for in-conduit applications. Fire alarm, notification devices, signaling, fire
    protective circuits. Two-hour direct flame cables for survivability requirements according to NFPA101.
    Zero halogen cables.
     

    SPECIFICATIONS
    1. Article 760 of NEC for Fire Alarm Circuit Integrity (CI) in conduit. NEC-FPLR. UL Standard 2196
    2. CONDUCTOR: Bare copper stranded and solid conductors
    3. INSULATION:Thermoset elastomer insulation
    4. SHIELDING: Corrosion-resistant Beldfoil shield, 100 percent coverage with tinned copper drain wire
    5. JACKET: Red polyolefin (PO)
    6. STANDARDS: NEC: FPLR, UL Listed. UL Electrical Circuit Protective Systems FHIT #30

    4. FPLR-CI Fire Alarm Unshielded

    SPECIFICATIONS
    1. Article 760 of NEC for Fire Alarm Circuit Integrity (CI). NEC-FPLR. UL Standard 2196
    2. CONDUCTOR: Bare copper solid conductors
    3. INSULATION:Thermoset elastomer insulation
    4. JACKET: Red polyolefin (PO)
    5. STANDARDS: NEC: FPLR, UL Listed. UL 2196 for Circuit Integrity in conduit, UL Electrical Circuit Protective Systems FHIT #30

    5. FPLR-CI Fire Alarm Shielded

    Circuit Integrity cable for riser applications, non-conduit and nonplenum. Fire alarm, notification
    devices, signaling, fire protective circuits. Two-hour direct flame cables for survivability
    requirements according to NFPA101. Zero halogen cables.
     

    SPECIFICATIONS
    1. Article 760 of NEC for Fire Alarm Circuit Integrity (CI). NEC-FPLR-CI. UL Standard 2196
    2. CONDUCTOR:Bare copper stranded and solid conductors
    3. INSULATION:Thermoset elastomer insulation
    4. SHIELDING: Corrosion-resistant Beldfoil shield 100 percent coverage with tinned copper drain wire
    5. JACKET: Red polyolefin (PO)
    6. STANDARDS: NEC: FPLR-CI, UL Listed