PART NUMBER: 71902
DESCRIPTION: 18/2 STRANDED CL3P/CMP/FPLP FT6 PLENUM CABLE
CONSTRUCTION: This cable consists of two bare copper insulated conductors and an overall jacket.
APPROVALS: UL Standard 13 and 444, NEC Articles 725 and 800.
APPLICATION: Class 3 Power Limited Circuit Cable and Communications Cable Used in Plenum Applications
Construction Parameters:
Conductor 18 AWG Bare Copper
Stranding 7/.0152"
Insulation Material Low Smoke PVC
Insulation Thickness 0.006 Nom.
Insulated Conductor Diameter 0.057 Nom.
Number of Conductors 2
Lay Length 5.00 Nom.
Jacket Material Low Smoke PVC
Jacket Thickness 0.014 Nom.
Overall Cable Diameter 0.142 Nom.
Approximate Cable Weight 17.9 Lbs/1M Nom.
Flame Rating NFPA 262 Steiner Tunnel Smoke and Flame Test
Electrical Properties:
Temperature Rating -20OC to 75OC
Operating Voltage 300V Max per NEC Article 800
Capacitance Between Conductors @ 1 KHz 38 pF/ft Nom.
Capacitance Between Conductors to Shield @ 1 KHz -----
DC Resistance per Conductor @ 20OC 6.29 Ohms/1M Nom.
Insulation Colors Black Red
Jacket Color Beige
Legend (Surface Ink Print) Coleman Cable 71902 18 AWG 2/C C(ETL) US (ETL CODE) TYPE CMP/CL3P/FPLP
75C -- TYPE CMP FT6