1. Multi-Conductors (UL) CL2P/CMP Individual Shield 耐高溫鐵氟龍個別隔離電線
    Multi-Conductors (UL) CL2P/CMP 耐高溫鐵氟龍電線
    Plenum Shielded低電容耐高溫鐵氟龍隔離電線
    Radix-High Temperature Wire 高溫線
    Radix-High Voltage Wire 高溫高壓線
    Radix-Multi Conductor Cables 多芯高溫高壓線
    回上一頁
  2. 產品搜尋
    分 類:
    關鍵字:  

    首頁 > > Radix-Multi Conductor Cables 多芯高溫高壓線

    Radix-Tempergard 2000   Mica glass/Fiberglass Braid/PTFE  22 AWG – 2 AWG 600V 450°C & 538°C 多芯鍍鎳雲母帶+玻璃絲編織高溫控制電纜
    看原圖
    5529375




    商品編號: Radix-Tempergard-2000

    Radix-Tempergard 2000 Mica glass/Fiberglass Braid/PTFE 22 AWG – 2 AWG 600V 450°C & 538°C 多芯鍍鎳雲母帶+玻璃絲編織高溫控制電纜


    For use in circuits where the preservation of circuit integrity under abusive, high
    temperature environments and resistance to abrasion, flame, oil, and other fluids
    is desired. Used in iron, steel, paper, and glass plants.

    450°C – 600 Volts - continuous temperature rating under normal service conditions
    538°C – 600 Volts - temporary temperature rating for short periods
    Passes NEMA WC 3 Flame Propagation Test
    Passes IEEE-383 (modified)210,000 BTU/hr Vertical Cable Tray Flame Test
    Maintains circuit integrity for a minimum of 2.5 hours
    under ICEA T-29-520 210,000 BTU/hr Vertical Flame Test
    Passes ICEA T-27-581 Water Absorption Test




    ★★★★商品說明★★★★

    TEMPERGARD 2000
    HIGH-TEMPERATURE CABLE
    450C/600V and 538C/600V
     

    RATINGS / APPROVALS
    450°C – 600 Volts - continuous temperature rating under normal service conditions
    538°C – 600 Volts - temporary temperature rating for short periods
    Passes NEMA WC 3 Flame Propagation Test
    Passes IEEE-383 (modified) 210,000 BTU/hr Vertical Cable Tray Flame Test
    Maintains circuit integrity for a minimum of 2.5 hours
    under ICEA T-29-520 210,000 BTU/hr Vertical Flame Test
    Passes ICEA T-27-581 Water Absorption Test
     

    CONSTRUCTION
    Conductors
    22 AWG – 2 AWG
    Flexible stranded nickel-coated copper-27%
    Insulating System
    Reinforced mica tape with fiberglass braid
    cover over each insulated conductor. High
    temperature tracers are woven into the braid
    for K-4 color coding. (Unless specified)
    Overall Binder Tapes
    Flame and heat resistant reinforced mica tape with fused
    PTFE fluoropolymer tape overall.
    Outer Covering
    Braided fiberglass with high temperature finish. Optional wire braid of
    stainless steel, nickel plated copper, other suitable material.
    Standard Color
    Black (Colors available)
     

    CHARACTERISTICS
    • Moisture, oil, fluid and abrasion resistant.
    • Fillers, where needed, are made with flame impervious fibers with moisture repellent finish.
    • Cable utilizes Radix “Torque Free” design. This eliminates memory found in
         traditional right hand or left hand twisted cables.
    • Binder tapes provide heat and moisture resistance.
    • Not recommended for outdoor use.
     

    APPLICATION
    For use in circuits where the preservation of circuit integrity under abusive, high
    temperature environments and resistance to abrasion, flame, oil, and other fluids
    is desired. Used in iron, steel, paper, and glass plants.