    Amer-37-102VFD Gexol® Insulated Standard VFD Power Cable Three Conductor • 2kV • Rated 110°C 3芯 柔性石油,天然氣海上鑽孔平台 or 起重機, 吊車等變頻馬達用線
    看原圖
    5525952

    商品編號: Amer-37-102VFD

    Amer-37-102VFD Gexol® Insulated Standard VFD Power Cable Three Conductor • 2kV • Rated 110°C 3芯 柔性石油,天然氣海上鑽孔平台 or 起重機, 吊車等變頻馬達用線
     

    Application
    A flexible, braid and foil shielded, 2kV power
    cable specifically engineered for use in variable
    frequency AC motor drive (VFD) applications.

    37-102VFD
    Standard VFD Power Cable
    Gexol® Insulated
    Three Conductor • 2kV • Rated 110°C

    Ratings & Approvals
    n 110°C Temperature Rating
    n American Bureau of Shipping (ABS): 03-HS290310-4
    n Transport Canada: 8700-20-2
    n Det Norske Veritas (DNV): E-11209, E-11213
    n Lloyd’s Register of Shipping (LRS): 09/00023
    n NVE: 95/1696, FAL
    n UL Listed as Marine Shipboard Cable: (E111461)
    n Unarmored Cable is UL Listed as Type TC (E123629)
    n United States Coast Guard: November 2, 1987 / 9304
       Other certifications pending

    Features
    n Specially engineered cable design produces
    a longer cable life in VFD applications.
    n Overall braid plus foil shield is engineered
       with 100% coverage and a surface transfer
       impedance <50 milliohms="" at="" 10mhz="">
       contain EMI.
    n Symmetrical insulated ground conductors
        reduce induced voltage imbalances and carry
        common mode noise back to the drive.
    n High strand count conductors and braid
        shield design is much more flexible, easier
        to install and more resistant to vibration
        than Type MC cable.
    n Gexol’s lower dielectric constant (standard
       XLPEs, EPRs and other Type P insulation
       materials have higher dielectric constants)
       reduces reflected wave peak voltage
       magnitudes. This allows for longer output
       cable distances and minimizes the effect
       of high frequency noise induced into the
       plant ground system.
    n 2kV insulation thickness is used to resist the
       potential 2-3x reflected voltages experienced
       in 600V VFD applications.
    n Dual certified IEEE 1580 Type P and
       UL 1309/CSA 245 Type X110.
    n Highest ampacity ratings: ABS 100°C, DNV
       95°C, LRS 95°C, Transport Canada 95°C.
    n Severe cold durability: exceeds CSA cold
       bend/cold impact (-40°C/-35°C).
    n Flame retardant: IEC 332-3 Category A
        and IEEE 1202.
    n Suitable for use in Class I, Division 1 and
       Zone 1 environments (armored and sheathed).
    n Optional braid armor of bronze, aluminum
        or tinned copper.