1. Amer-37-119 DLO 2kV
    Amer-Gexol® Insulated Oil & Gas Cables
    Amer-Industrial Cables
    回上一頁
  2. 產品搜尋
    分 類:
    關鍵字:  

    首頁 > > Amer-37-119 DLO 2kV

    37-119-210 Awg 1 Flexible Power Cable • DLO EP/CPE • RHH, RHW-2 • 2000 Volts 90°C 柔性耐高壓高溫電線
    看原圖
    5517721

    商品編號: Amer-37-119-210

    37-119-210 Awg 1 Flexible Power Cable • DLO EP/CPE • RHH, RHW-2 • 2000 Volts 90°C 柔性耐高壓高溫電線

    Ratings & Approvals
    􀀀ICEA S-95-658/ NEMA WC-70: Nonshielded Power
         Cables Rated 2000 Volts or Less for the
         Distribution of Electrical Energy
    􀀀 UL Standard 44: Thermoset Insulated Wires &
         Cables, Types RHH, RHW-2. UL VW-1
    􀀀 UL Standard 1685: Vertical Tray Fire propagation
         and Smoke Release Test for Electrical and
         optical Fiber Cables. (UL,ST-1)
    􀀀 ASTM B-33: Standard Specification for Tinned Soft
         or Annealed Copper Wire for Electrical Purposes
    􀀀 ASTM B-172: Standard Specification for
         Rope-Lay-Stranded Copper Conductors having
         Bunch-Stranded Members, for Electrical
         Conductors
    􀀀 MSHA P-184

    Application


    AmerCable’s2000V Diesel Locomotive
    Cable (DLO) is a single conductor portable
    power cable suitable for use in applications
    needing great flexibility, excellent wearability
    and good flex life. Applications include
    locomotive and car equipment, motor and
    generator leads, battery leads, shipyards,
    telecommunications power, heavy earth
    moving equipment, renewable energy and
    other heavy duty flexing applications.
     

    Features
    􀀀 A two layer composite of flame retardant,
         oil and sunlight resistant Chlorinated
         Polyethylene (CPE) outer layer and Ethylene-
         Propylene rubber (EPR) inner layer. The
         composite design provides significant
         diameter reductions compared to designs
         using full thickness jackets.
    􀀀 Suitable for continuous operating
        temperatures of 90°C, wet or dry
    􀀀Rated RHH, RHW-2; 2/0 – 1111 kcmil
        listed and marked “for CT use”
    􀀀 UL listed as Sunlight Resistant
    􀀀 UL listed as Marine Shipboard Cable
         (4/0 and larger) – Special order only
    􀀀 Insulation and jacket meet hazardous
         waste regulations, per Code of Federal
         Regulations 40 Section 261 (40CFR261)
         for characteristic lead content
    􀀀 Flame Resistance: FT-4/IEEE1202 for
         2/0 – 1111 kcmil and UL VW-1
    􀀀 Meets smoke release and other requirements
         of Vertical Cable Tray Test UL 1685
         and is marked “ST-1” for 2/0 – 1111 kcmil
    􀀀 Extremely flexible stranding used for
         increased flexibility and ease of installation