1. BLACKBOX-光纖數據機(Fiber Modem)
    BLACKBOX-多工器(Multiplexer/Mux)
    BLACKBOX-延長器(Extender)
    BLACKBOX-數據機模擬器(Modem Eliminator)
    BLACKBOX-有限距離數據機(Short-Haul Modem)
    BLACKBOX-訊號放大器(Line Driver)
    BLACKBOX-資料分享器(Data Sharing)
    BLACKBOX-資料廣播器(Data Broadcasting)
    回上一頁
  2. 產品搜尋
    分 類:
    關鍵字:  

    首頁 > > BLACKBOX-有限距離數據機(Short-Haul Modem)

    BLACKBOX-ME375A-R2  Async/Sync RS-232 2-Wire Short-Haul Modem   2線同步/非同步有限距離數據機, DB25
    看原圖
    5215844




    商品編號: BLACKBOX-ME375A-R2

    BLACKBOX-ME375A-R2 Async/Sync RS-232 2-Wire Short-Haul Modem 2線同步/非同步有限距離數據機, DB25


    Blast off! Transmit async or sync data at rocket speeds!



    ★★★★商品說明★★★★

    Description

    Async/Sync RS-232 2-Wire Short-Haul Modem


    Quick Facts

  3. Transmits async data up to 38.4 kbps and sync data up to 128 kbps using 2B1Q line coding.
     

  4.  

    Further Details

  5. Adaptive equalizer provides noise immunity and high performance over low-quality lines.
  6. Full diagnostics include internal BERT and local and remote loopbacks.
  7. Full-duplex operation using echo cancellation.
  8. Single sync/async channel.
  9. 2-wire, twisted-pair operation.
  10. Transmits at over 3 miles (5.4 km)—even at maximum speeds.

    The Async/Sync 2-Wire Short-Haul Modem runs at amazing speeds—async data goes 38.4 kbps; sync data travels at 128 kbps. And you get this astounding data rate even at this modem’s maximum distance of 3.4 miles (5.4 km) over your existing, inexpensive, 2-wire twisted-pair lines! Because of the short-haul modem’s adaptive echo-cancelling technique, full-duplex is possible over only two wires.

    Perform diagnostics on local analog loopback as well as local and remote digital loopback. You can test both the local and remote modems and the line at either end when you’re in the digital loopback mode. And you can control the loopbacks with a manual switch or through the DTE interface.

    This short-haul modem is coupled to the line through an isolation transformer that protects against AC or DC overvoltages, and internal, external, and receive clocking keep your data moving smoothly.
     
  11. Technical Specifications for Async/Sync RS-232 2-Wire Short-Haul Modem:

    Clocking — Internal, external, receive
    Distance (Maximum) — 3.4 mi. (5.4 km) over 26 AWG wire
    Operation — Full-duplex
    Protocol — Async or sync
    Speed (Maximum) — Async: 38.4 kbps;
    Sync: 128 kbps
    Interface — RS-232 (DCE)
    Connectors — (1) DB25 F, (1) 4-screw terminal block, (1) RJ-45
    Power — 115 VAC, 60 Hz (230-VAC, 50-Hz version on request)
     
    NOTE: Must be used in pairs.

    This product works with:
    • GigaBase® 350 CAT5e, 350-MHz Bulk Cable, 4-Pair (EYN851A-PB-1000)
    • Standard RS-232 Low-Noise Cable, 25-Conductor (ECM25T, ECM25C)