1. Photovoltaic wire 太陽能光伏電纜
    ALPHA-SOLAR Manage ground and protect 太陽能管理、接地和保護
    ALPHA-SOLAR WIRE 太陽能用電線電纜
    回上一頁
  2. 產品搜尋
    分 類:
    關鍵字:  

    首頁 > > ALPHA-SOLAR WIRE 太陽能用電線電纜

    ALPHA PVT1228 AWG-12 1,000V LSZH TUV 2PfG 1169/08.2007, REACH (EC 1907/2006), ROHS, UL -40C, UL 4703, PV WIRE, SUN RES, VW-1低煙無鹵美歐雙認證太陽能光伏電線
    看原圖
    ALPHA-PVT1228

    商品編號: ALPHA-PVT1228

    ALPHA-PVT1228 AWG-12 1,000V LSZH TUV 2PfG 1169/08.2007, REACH (EC 1907/2006), ROHS, UL -40C, UL 4703, PV WIRE, SUN RES, VW-1
    低煙無鹵美歐雙認證太陽能光伏電線
    Part # Voltage AWG Stranding Insulation Thickness Insulation Diameter Insulation Material Applicable Specifications
    PVT1228 1000 12 56/28 0.045 0.252 LSZH OTHER - TUV 2PfG 1169/08.2007, REACH Regulation (EC 1907/2006), ROHS - RoHS Compliance, UL -40C, UL 4703, UL PV WIRE, UL SUN RES, UL VW-1

    特点

    • 防日晒、臭氧和紫外线
    • 防潮
    • 符合 RoHS (《电气、电子设备中限制使用某些有害物质指令》)
    • 遵守 REACH
    • 温度范围:-40°C 到 +90°C
    1) Component 1 1 X 1 HOOKUP  
    a) Conductor 12 (56/28) AWG TC 0.102
    b) Insulation 0.045" Wall, Nom. Low Smoke Zero Halogen (LSZH) 0.192+/- 0.004
    (1) Color(s) WHITE
    2) Jacket 0.030" Wall, Nom.,Low Smoke Zero Halogen (LSZH) 0.252+/- 0.010
    a) Color(s) BLACK
    b) Print ALPHA WIRE-* P/N PVT1228
    12 AWG 4MM2 E331483 (UL) PV WIRE 90C WET OR DRY
    600V SUN RES -40C --- TUV 2PFG 1169 1000V LSZH
    ROHS CE
    * = Factory Code
     
    1) UL VW-1  
      SUN RES  
      -40C  
      UL 4703, PV Wire 90°C Dry / 90°C Wet / 600 VRMS
    2) IEC EN 60332-1 Flame Behavior  
      EN 60754-1 Acid Gas Generation  
      EN 60754-2 Acid Gas Generation  
      EN 61034-2 Smoke Emission  
      EN 60811-2-1 Ozone Resistance  
      EN 60228 Conductors, Class 2  
    3) Other EN-ISO 4892 UV Resistance  
      TUV 2PfG 1169/08.2007  
    4) CE: LVD 73/23/EEC Amendment 93/68/EEC
    1) EU Directive 2002/95/EC(RoHS):
      All materials used in the manufacture of this part are in compliance with EU Directive 2002/95/EU regarding the restriction of use of certain hazardous substances in electrical and electronic equipment. Consult Alpha Wire's web site for compliance Date of Manufacture.
    2) REACH Regulation (EC 1907/2006):
      This product does not contain any of the substances listed on the European Union REACH Substance of Very High Concern (SVHC) candidate list, dated 30 March 2010, in excess of a concentration of 0.1% weight/weight.
    Physical & Mechanical Properties
    1) Temperature Range -40 to 90°C
    2) Bend Radius 5X Cable Diameter(static), 4X Cable Diameter(dynamic)
    3) Pull Tension 65 Lbs, Maximum
    Electrical Properties (For Engineering purposes only)
    1) Voltage Rating 1000 VRMS
    2) Inductance 0.05 µH/ft, Nominal
    3) Conductor DCR 1.36 Ω/1000ft @20°C, Nominal
    Packaging Flange x Traverse x Barrel (inches)
    a) 1000 FT 12 x 12 x 3.5 Continuous length
    b) 100 FT 10 x 4 x 3.5 Continuous length
      [Spool dimensions may vary slightly]

    Our photovoltaic wire gives you flexible choices to meet UL 4703 PV wire and UL 4703 PV wire/TÜV 2 PFG 1169 wire requirements.

    Features:

    • Sunlight, ozone, and UV resistant
    • Moisture resistant
    • RoHS compliant
    • REACH compliant
    • -40°C to +90°C temperature range

     

      Part # Voltage AWG Stranding Insulation Thickness Insulation Diameter

     

    Insulation Material
    PV0230 2000 2 665/30 0.078 0.558 XLPE REACH Regulation (EC 1907/2006), ROHS - RoHS Compliance, UL -40C, UL PV WIRE, UL SUN RES, UL VW-1
    PV0430 2000 4 420/30 0.078 0.491 XLPE REACH Regulation (EC 1907/2006), ROHS - RoHS Compliance, UL -40C, UL PV WIRE, UL SUN RES, UL VW-1
    PV0630 2000 6 266/30 0.078 0.433 XLPE REACH Regulation (EC 1907/2006), ROHS - RoHS Compliance, UL -40C, UL PV WIRE, UL SUN RES, UL VW-1
    PV0830 2000 8 168/30 0.078 0_390 XLPE REACH Regulation (EC 1907/2006), ROHS - RoHS Compliance, UL -40C, UL PV WIRE, UL SUN RES, UL VW-1
    PV1030 2000 10 105/30 0.063 0.311 XLPE CSA RW 90, REACH Regulation (EC 1907/2006), ROHS - RoHS Compliance, UL PV WIRE, UL SUN RES, UL VW-1
    PV1230 2000 12 65/30 0.063 0.286 XLPE CSA RW 90, REACH Regulation (EC 1907/2006), ROHS - RoHS Compliance, UL PV WIRE, UL SUN RES, UL VW-1
    PV1430 2000 14 41/30 0.063 0.267 XLPE CSA RW 90, REACH Regulation (EC 1907/2006), ROHS - RoHS Compliance, UL PV WIRE, UL SUN RES, UL VW-1
    PVT0226 1000 2 279/26 0.06 0.484 LSZH OTHER - TUV 2PfG 1169/08.2007, REACH Regulation (EC 1907/2006), ROHS - RoHS Compliance, UL -40C, UL 4703, UL PV WIRE, UL SUN RES, UL VW-1
    PVT0426 1000 4 199/26 0.06 0.436 LSZH OTHER - TUV 2PfG 1169/08.2007, REACH Regulation (EC 1907/2006), ROHS - RoHS Compliance, UL -40C, UL 4703, UL PV WIRE, UL SUN RES, UL VW-1
    PVT0626 1000 6 128/26 0.06 0.386 LSZH OTHER - TUV 2PfG 1169/08.2007, REACH Regulation (EC 1907/2006), ROHS - RoHS Compliance, UL -40C, UL 4703, UL PV WIRE, UL SUN RES, UL VW-1
    PVT0826 1000 8 78/26 0.06 0.340 LSZH OTHER - TUV 2PfG 1169/08.2007, REACH Regulation (EC 1907/2006), ROHS - RoHS Compliance, UL -40C, UL 4703, UL PV WIRE, UL SUN RES, UL VW-1
    PVT1028 1000 10 84/28 0.045 0.275 LSZH OTHER - TUV 2PfG 1169/08.2007, REACH Regulation (EC 1907/2006), ROHS - RoHS Compliance, UL -40C, UL 4703, UL PV WIRE, UL SUN RES, UL VW-1
    PVT1228 1000 12 56/28 0.045 0.252 LSZH OTHER - TUV 2PfG 1169/08.2007, REACH Regulation (EC 1907/2006), ROHS - RoHS Compliance, UL -40C, UL 4703, UL PV WIRE, UL SUN RES, UL VW-1
    PVT1430 1000 14 50/30 0.045 0.230 LSZH  

    Alpha PVT0226, Alpha PVT0426, Alpha PVT0626, Alpha PVT0826, Alpha PVT1028, Alpha PVT1228,

    ALPHA,PVT1228, LSZH, TUV 2PfG, UL 4703, PV WIRE, SUN RES, VW-1 低煙無鹵美歐雙認證太陽能光伏電線,google,tyco, anixter,mouser