    3M-3C Three Conductor 第三代冷縮式末端處理頭(屋外 25KV)
    看原圖
    3M-QT-3-3W

    QT-III Silicone Rubber - Three Conductor
    3M Three Conductor Cable Termination Kits 7600 Series are designed to terminate medium voltage power cables rated up to 35 kV. 7600-3G series kits are designed for three conductor cables with internal ground wires. 7600-3W series kits are designed for three conductor cables without internal ground wires. 7600-RJS series kits are designed for cabinet-mount installations and can be used on cables with, or without, internal ground wires. Each termination kit has all of the materials required to make a three conductor termination (except lugs, which must be ordered separately).
     
    Kit components include:
    • Three QT-III Silicone Rubber Termination assemblies, tubular or skirted depending upon the termination
    environment and location. 
    • Three four-foot RJS Silicone Rubber Re-jacketing Sleeve assemblies.
    • The 7600-3W series kits also include a silicone rubber breakout boot.
    Cable Types for Terminating

    3/C Copper Tape Shielded Cable
     
    3/C Copper Tape Shielded Cable - Armored
    Termination Type Selection Guide for Three Conductor Cable 7600 Series
    Kit
    Series
    Insulator
    Configuration
    Installation
    Environment
    Orientation For Cable Type(s)
    (With or Without Ground Wires)
    7600-S-3G
    7600-T-3G
    7690-S-INV-3G
    7600-S-3-RJS
    7600-T-3-RJS
    7690-S-INV-3-RJS
    7600-S-3W
    7600-T-3W
    7690-S-INV-3W 
    Skirted
    Tubular
    Skirted
    Skirted
    Tubular
    Skirted
    Skirted
    Tubular
    Skirted
    Outdoor
    Indoor
    Outdoor
    Indoor-Cabinet Mount (No Breakout
    Indoor-Cabinet Mount (No Breakout
    Indoor-Cabinet Mount (No Breakout
    Outdoor
    Indoor
    Outdoor 
    Normal
    Normal
    Inverted
    Normal
    Normal
    Inverted
    Normal
    Normal
    Inverted 
    With ground wires
    With ground wires
    With ground wires
    With or Without ground wires
    With or Without ground wires
    With or Without ground wires
    Without ground wires
    Without ground wires
    Without ground wires 
    We have 7600-T-3W, 7600-S-3W,  7690-S-INV-3W in Stock.
    7600-T-3W Series — Kit Selection Guide
     
    Kit Number BIL
    kV
    Cable Insulation Range in. (mm) 3.3 kV (mm2) IEC 3.3 kV (mm2) JIS 5.0 kV (AWG) AEIC 6.6 kV (mm2) JIS 6.6 kV (mm2) IEC 8.7 kV (AWG) AEIC 10 kV (mm2) IEC UPC
    (051131-)
    7620-T-95-3W 95 0.33-0.50 (8.40-12.7) 16-35 8-22 8-2 16-25 6-4 04731
    7621-T-95-3W 95 0.50-0.70 (12.7-17.8) 50-95 38-60 1-3/0 35-70 2-2/0 10-50 04732
    7623-T-95-3W 95 0.70-0.92 (17.8-23.4) 120-185 100-150 4/0-400 95-150 3/0-350 70-150 04733
    7624-T-95-3W 95 0.92-1.18 (23.4-30.0) 240-300 200-250 500-750 185-300 400-600 185-300 04734
    7625-T-95-3W 95 1.18-1.52 (30.0-38.6) 300-325 800-1000 750-1000 04735
    7621-T-110-3W 110 0.50-0.70 (12.7-17.8) 50-95 38-60 1-3/0 14-38 35-70 2-2/0 10-50 04736
    7622-T-110-3W 110 0.70-0.92 (17.8-23.4) 120-185 100-150 4/0-400 60-100 95-150 3/0-350 70-150 04737
    7624-T-110-3W 110 0.92-1.18 (23.4-30.0) 240-300 200-250 500-750 150-250 185-300 400-600 185-300 04738
    7625-T-110-3W 110 1.18-1.52 (30.0-38.6) 300-325 800-1000 300-325 750-1000 04739
    7622-T-125-3W 125 0.70-0.92 (17.8-23.4) 120-185 100-150 4/0-400 60-100 95-150 3/0-350 70-150 04740
    7624-T-125-3W 125 0.92-1.18 (23.4-30.0) 240-300 200-250 500-750 150-250 185-300 400-600 185-300 04741
    7625-T-125-3W 125 1.18-1.52 (30.0-38.6) 300-325 800-1000 300-325 750-1000 04742
    7693-T-150-3W 150 0.70-0.92 (17.8-23.4) 120-185 100-150 4/0-400 60-100 950-150 3/0-350 70-150 41743
    7694-T-150-3W 150 0.92-1.18 (23.4-30.0) 240-300 200-250 500-750 150-250 185-300 400-600 185-300 04744
    7695-T-150-3W 150 1.18-1.52 (30.0-38.6) 300-325 800-1000 300-325 750-1000 04745
      
    Kit Number BIL kV Cable Insulation Range in. (mm) 15 kV (mm2) IEC 15 kV (AWG) AEIC 20 kV (mm2) IEC 25/28 kV (AWG) AEIC UPC
    (051131-)
    7620-T-95-3W 95 0.33-0.50 (8.40-12.7) 04731
    7621-T-95-3W 95 0.50-0.70 (12.7-17.8) 16-25 04732
    7623-T-95-3W 95 0.70-0.92 (17.8 23.4) 35-95 04733
    7624-T-95-3W 95 0.92-1.18 (23.4-30.0) 120-185 04734
    7625-T-95-3W 95 1.18-1.52 (30.0-38.6) 200-325 04735
    7621-T-110-3W 110 0.50-0.70 (12.7-17.8) 6-25 2-1 04736
    7622-T-110-3W 110 0.70-0.92 (17.8-23.4) 35-95 1/0-4/0 04737
    7624-T-110-3W 110 0.92-1.18 (23.4-30.0) 120-185 250-450 04738
    7625-T-110-3W 110 1.18-1.52 (30.0-38.6) 200-325 500-750 04739
    7622-T-125-3W 125 0.70-0.92 (17.8-23.4) 35-95 1/0-4/0 25-70 04740
    7624-T-125-3W 125 0.92-1.18 (23.4-30.0) 120-185 250-450 95-185 04741
    7625-T-125-3W 125 1.18-1.52 (30.0-38.6) 200-325 500-750 240-300 04742
    7693-T-150-3W 150 0.70-0.92 (17.8-23.4) 35-95 1/0-4/0 25-70 2-1/0 04743
    7694-T-150-3W 150 0.92-1.18 (23.4-30.0) 120-185 250-450 95-185 2/0-250 04744
    7695-T-150-3W 150 1.18-1.52 (30.0-38.6) 200-325 500-750 240-300 300-500 04745
     
    7600-S-3W Series — Kit Selection Guide
    Kit Number BIL kV Cable Insulation Range in. (mm) 3.3 kV (mm2) IEC 3.3 kV (mm2) JIS 5.0 kV (AWG) AEIC 6.6 kV (mm2) JIS 6.6 kV (mm2) IEC 8.7 kV (AWG) AEIC 10 kV (mm2) IEC UPC (051131-)
    7620-S-2-3W 95 0.33-0.50 (8.40-12.7) 16-35 8-22 8-2 16-25 6-4 04748
    7621-S-2-3W 95 0.50-0.70 (12.7-17.8) 50-95 38-60 1-3/0 35-70 2-2/0 10-50 04749
    7622-S-2-3W 110 0.70-0.92 (17.8-23.4) 120-185 100-150 4/0-400 60-100 95-150 3/0-350 70-150 04750
    7691-S-4-3W 150 0.50-0.70 (12.7-17.8) 50-95 38-60 1-3/0 35-70 2-2/0 10-50 04751
    7692-S-4-3W 150 0.70-0.92 (17.8-23.4) 120-185 100-150 4/0-400 60-100 95-150 3/0-350 70-150 04752
    7693-S-4-3W 150 0.92-1.18 (23.4-30.0) 240-300 200-250 500-750 150-250 185-300 400-600 185-300 04753
    7695-S-4-3W 150 1.18-1.52 (30.0-38.6) 300-325 800-1000 300-325 750-1000 04754
    7684-S-8-3W 200 0.92-1.18 (23.4-30.0) 240-300 200-250 500-750 150-250 185-300 400-600 185-300 04755
    7685-S-8-3W 200 1.18-1.52 (30.0-38.6) 300-325 800-1000 300-325 750-1000 04756
     
    Kit Number BIL kV Cable Insulation Range in. (mm) 15 kV (mm2) IEC 15 kV (AWG) AEIC 20 kV (mm2) IEC 25/28 kV (AWG) AEIC 30 kV (mm2) IEC 35 kV (AWG) AEIC UPC (051131-)
    7620-S-2-3W 95 0.33-0.50 (8.40-12.7) 04748
    7621-S-2-3W 95 0.50-0.70 (12.7-17.8) 16-25 04749
    7622-S-2-3W 110 0.70-0.92 (17.8-23.4) 35-95 1/0-4/0 04750
    7691-S-4-3W 150 0.50-0.70 (12.7-17.8) 16-25 04751
    7692-S-4-3W 150 0.70-0.92 (17.8-23.4) 35-95 1/0-4/0 25-70 2-1/0 04752
    7693-S-4-3W 150 0.92-1.18 (23.4-30.0) 120-185 250-450 95-185 2/0-250 04753
    7695-S-4-3W 150 1.18-1.52 (30.0-38.6) 200-325 500-750 240-300 300-500 04754
    7684-S-8-3W 200 0.92-1.18 (23.4-30.0) 120-185 250-450 95-185 2/0-250 35-70 1/0-3/0 04755
    7685-S-8-3W 200 1.18-1.52 (30.0-38.6) 200-325 500-750 240-300 300-500 95-240 4/0-500 04756
     
    7690-S-INV-3W Series — Kit Selection Guide
    Kit Number BIL
    kV
    Cable Insulation Range in. (mm) 3.3 kV (mm2) IEC 3.3 kV (mm2) JIS 5.0 kV (AWG) AEIC 6.6 kV (mm2) JIS 6.6 kV (mm2) IEC 8.7 kV (AWG) AEIC 10 kV (mm2) IEC UPC
    (051131-)
    7693-S-4-INV-3W 150 0.92-1.18 (23.4-30.0) 240-300 200-250 500-750 150-250 185-300 400-600 185-300 04746
    7695-S-4-INV-3W 150 1.18-1.52 (30.0-38.6) ? 300-325 800-1000 300-325 ? 750-1000 ? 04747
     
    Kit Number BIL kV Cable Insulation Range in. (mm) 15 kV (mm2) IEC 15 kV (AWG) AEIC 20 kV (mm2) IEC 25/28 kV (AWG) AEIC UPC
    (051131-)
    7693-S-4-INV-3W 150 0.92-1.18 (23.4-30.0) 120-185 250-450 95-185 2/0-250 04746
    7695-S-4-INV-3W 150 1.18-1.52 (30.0-38.6) 200-325 500-750 240-300 300-500 04747
     

    8560 Series 3/C Cable Breakout Boots
    8560 Series Breakout Boots are designed to protect the phase leg breakout of 3/C medium voltage power cable from exposure to moisture, contamination, corrosion, ozone, ultra-violet radiation, physical contact and other hazards associated with 3/C termination operating environments. 8560 Series Breakout Boots can be used in conjunction with 3M Silicone Rubber Cold Shrink Rejacketing Sleeves for 3/C shielded power cable terminating applications.
     
    Product Number Cable Phase Shield Diameter Range [A] Cable Outer Jacket Diameter Range [B]  pcs/box boxes/case
    8561 0.48 – 0.72" (12,2 – 18,3 mm) 1.17 – 1.94" (29,7 – 49,3 mm)  1 16 
    8561 0.61 – 0.95" (15,5 – 24,2 mm) 1.46 – 2.67" (37,1 – 67,8 mm)  1  16
    8563 0.82 – 1.18" (20,8 – 30,0 mm) 1.92 – 3.10" (48,8 – 78,7 mm)  1  16
    8564 1.02 – 1.63" (26,0 – 41,4 mm) 2.52 – 4.32" (64,0 – 109,8 mm)  1  16
    8565 1.09 – 1.94" (27,7 – 49,3 mm) 2.60 – 4.70" (66,1 – 119,4 mm)  1  16
    3M 3/C Phase Rejacketing System
    Rejacketing sleeves are designed to protect the phase legs (core) of 3/C shielded power cable from exposure to moisture, corrosion, ozone, ultra-violet radiation, physical contact and other hazards that are associated with termination operating environments. Rejacketing sleeves are designed to be used in conjunction with 3M Cold Shrink Breakout Boots and Silicone Rubber Terminations.
    Product Number Metallic Shield Diameter Range 3.3 KV (mm2) IEC 3.3 KV (mm2) JIS 5.0 KV (AWG) AEIC 6.6 KV (mm2) IEC 6.6 KV (mm2) JIS 8.0 KV (AWG) AEIC
    RJS – 1 0.43 – 0.60" 10,9 – 15,2 mm 16 – 35 8 – 22 8 – 2 16 – 25 8 – 10 6 – 4
    RJS – 2 0.60 – 0.80" 15,2 – 20,3 mm 50 – 95 38-60 1 – 3/0 35 – 70 14 – 38 2 – 2/0
    RJS – 3 0.80 – 1.02" 20,3 – 26,0 mm 120 – 185 100 – 150 4/0 – 400 95 – 150 60 – 100 3/0 – 350
    RJS – 4 1.02 – 1.28" 25,9 – 32,4 mm 240 – 300 200 – 250 500 – 750 185 – 300 150 – 250 400 – 600
    RJS – 5 1.28 – 1.62" 300 – 325 800 – 1000 300 – 325 750 – 1000
     
    Product Number Metallic Shield Diameter Range 10 KV (mm2) IEC 15 KV (AWG) AEIC 20 KV (mm2) IEC 25 KV (AWG) AEIC 30 KV (mm2) IEC 35 KV (AWG) AEIC
    RJS – 1 0.43 – 0.60" 10,9 — 15,2 mm
    RJS – 2 0.60 – 0.80" 15,2 – 20,3 mm 10 – 50 2 – 1
    RJS – 3 0.80 – 1.20" 20,3 – 26,0 mm 70 – 150 1/0 – 4/0 25 – 70 2 – 1/0    
    RJS – 4 1.02 – 1.28" 25,9 – 32,4 mm 185 – 300 250 – 450 95 – 185 2/0 – 250 35 – 70 1/0 – 3/0
    RJS – 5 1.28 – 1.62" 500 – 750 240 – 300 300 – 500 95 – 240 4/0 – 500