    AMP(Tyco)-1375055-1 SL Series 110Connect Category 6 Jacks 資訊插座(SL) 2樣
    看原圖
    AMP-1375055-1

    AMP(Tyco) 1375055-1 SL Series 110Connect Category 6 Jacks 資訊插座(SL) 2樣
     
    商品編號: AMP-1375055-1

    AMP(Tyco)-1375055-1 SL Series 110Connect Category 6 Jacks 資訊插座(SL) 2樣

    Description
    AMP NETCONNECT Category 6 jacks exceed TIA/EIA-568-B.2-1 and IEC 60603-7-4 requirements for
    Category 6 component performance. The AMP NETCONNECT Category 6 System complies with all of
    the performance requirements for current and proposed applications such as Gigabit Ethernet, 100BASETx,
    token ring, 155 Mbps ATM, 100 Mbps TP-PMD, ISDN, analog (broadband, baseband) and digital
    video and analog and digital (VoIP) voice. These slim profile jacks are compatible with SL Series and
    110Connect faceplates. Universal wiring labels permit termination to either T568A or T568B wiring
    patterns. The jacks are available with and without integral dust covers and in a shielded version as well.
    Cables may be dressed at either 180O or 90O for added flexibility at various outlet locations. Patented
    bend-limiting strain relief may also be used to reduce stress on cable at point of termination.
    Specification (Text in brackets [ ] requires a choice.)


    Modular jacks shall be unkeyed, 4-pair and shall meet the Category 6 performance requirements listed in
    the following table [include Performance Characteristics table from back page]. Modular jacks shall fit in
    a .790" X .582" opening. Modular jacks shall be terminated using 110-style pc board connectors, colorcoded
    for both T568A and T568B wiring. The 110-style connectors shall be capable of terminating 22-24
    AWG solid wire. 110 Contacts shall be paired (with additional space between pairs) to improve crosstalk
    performance. [Each jack shall be provided with a bend-limiting strain relief. The strain relief shall provide
    a “silo” to limit the bend radius at the point of termination (unshielded jacks only)]. [Each jack shall
    incorporate an integral, hinged dust cover]. Modular jacks shall utilize a secondary PC board, separate
    from the signal path, for crosstalk compensation. Each jack shall be wired to [T568A or T568B]. Modular
    jacks shall be UL Listed under file number E81956. Modular jacks shall be AMP NETCONNECT part
    number [insert part number].