    MEGADOR JUNIOR Cat. 6 4x(2x23 AWG) S/FTP Data cable

    Part Number:
    9828604xxx
     

    Applications: Indoor use, fixed installations, High bandwidth digital applications with low BER, High data rates
    General Construction: The cable consists of 4 individually shielded twisted pairs that are cabled, overall braid shielded and jacketed.
    Outer Jacket Material: FR-PVC
    Outer Diameter: 8.2 mm nom.
    Weight: 70 kg/km
    Design & Materials
    Conductor Material: Bare Copper
    Conductor Size: 23 AWG
    Conductor Size: 0.58 mm
    Conductor Construction: Solid
    Insulation Material: SFS PO
    Insulation O.D.: 1.43 mm nom.
    Color code: Per TIA/EIA 568-B
    Ind. Shield Material: Aluminum/Polyester Foil
    Ind. Shield Design: Aluminum face outwards
    Overall Shield Material: Tinned-copper braid
    Overall Braid Shield: Yes
    Braid Coverage: min. 55 % nom.
    Outer Jacket Color: See TELDOR Jacket Code
    Marking: Per request
    Standards
    Standards: IEC 61156, ISO/IEC 11801, TIA/EIA-568
    Flamability Rating: IEC 60332-1, UL 1581 VW-1
    Performance
    Electrical Properties:  
    Cat. 6 Screened-Pair Horizontal Cables*
     

    Freq.

    MHz

    Attenuation
    dB/100m
    20oC

    PS NEXT Loss
    dB

    NEXT Loss
    dB

    RL
    dB

    PS ELFEXT
    dB
    ELFEXT
    dB
    Typical
    Value

    Cat. 6

    Typical
    Value
    Cat. 6
     
    Typical
    Value

    Cat. 6

    Typical
    Value

    Cat. 6

    Typical
    Value

    Cat. 6

    Typical
    Value

    Cat. 6

    1

    2.0

    2.8

    90.0

    72.3

    93.0

    75.3

    22.0

    20.0

    90.0

    65.0

    93.0

    68.0

    4

    3.7

    3.8

    85.0

    63.3

    88.0

    66.3

    25.0

    23.0

    90.0

    53.0

    93.0

    56.0

    10

    5.7

    6.0

    85.0

    57.3

    88.0

    60.4

    28.0

    25.0

    80.0

    45.0

    83.0

    48.0

    20

    8.1

    8.5

    85.0

    52.8

    88.0

    55.8

    28.0

    25.0

    80.0

    39.0

    83.0

    42.0

    30

    10.0

    10.5

    85.0

    50.1

    88.0

    53.1

    27.0

    23.8

    70.0

    35.5

    73.0

    38.5

    100

    19.0

    19.9

    80.0

    42.3

    83.0

    45.3

    24.0

    21.1

    63.0

    25.0

    66.0

    28.0

    150

    23.6

    24.9

    80.0

    39.7

    83.0

    42.7

    22.0

    18.8

    60.0

    21.5

    63.0

    24.5

    200

    27.7

    29.1

    80.0

    37.8

    83.0

    40.8

    21.0

    18.0

    58.0

    19.0

    61.0

    22.0

    250

    31.4

    33.0

    77.0

    36.3

    80.0

    39.3

    20.0

    17.3

    55.0

    17.0

    58.0

    20.0


    *Supplied cables meet the minimum Cat. 6 transmission requirements as per IEC 61156-5 Ed. 2

     
    Frequency Range: 1 - 250 MHz
    Impedance: 100 Ω
    Coupling Attenuation: Type I
    Max. Resistance Unbalance: 2 %
    Capacitance Unbalance: 1.2 pF/m max.
    Propagation Delay Skew: 35 ns/100m max.
    Min. Insulation Resistance : 5 GΩ•km
    Max. Tensile Strength - Short Term: 140 N
    Min. Bend Radius: 31 mm
    Max. Operating Temperature: +70 °C
    Min. Operating Temperature: -30 °C