    Teldor-9928284xxx GIGA-PATCH Cat. 7 600 Mhz 4x(2x26/7 AWG ) S/FTP PU Tactic CAT-7 4P 低煙無鹵PU 網路線
    看原圖
    Teldor-9928284xxx

    Teldor-9928284xxx GIGA-PATCH Cat. 7 600 Mhz 4x(2x26/7 AWG ) S/FTP PU Tactic CAT-7 4P 低煙無鹵PU 網路線

    GIGA-PATCH Cat. 7 600 Mhz 4x(2x26/7 AWG ) S/FTP PU Tactic

    Part Number:
    9928284xxx
     

    Applications: Indoor/Outdoor use, fixed installations, High data rates, Work area cabling, Fixed or portable installations, Indoor use, portable installations, Patch cord, Outdoor installations in harsh environments
    General Construction:
    The cable contains 4 individually foil-shielded twisted pairs, overall braid-shielded, and jacketed with PU UV resistant compound.
    The cable conforms to IEC 61156-6, Cat. 5e, Cat. 6, Cat.6A and Cat. 7 requirements for shielded pairs of stranded conductors.
    compatible with RJ-45 modular plugs.
    Outer Jacket Material: FRZH-PU
    Outer Diameter: 6.5 mm nom.
    Weight: 40 kg/km
    Design & Materials
    Detailed Construction:  
    Cable features
    1. Excellent resistance to oils, fuels, and chemicals
    2. Very good crush resistant
    3. Designed for tactic applications and use.
     
     
    Conductor Material: Bare Copper
    Conductor Size: 26 AWG
    Conductor Size: 7x0.17 mm
    Conductor Construction: Stranded
    Insulation Material: PO
    Insulation O.D.: 1.0 mm nom.
    Color code: Per TIA/EIA 568-B
    Ind. Shield Material: Aluminum/Polyester Foil
    Ind. Shield Design: Aluminum face outwards
    Conductor unit lay-up: Pairs
    Overall Braid Shield: Yes
    Overall Braid Material: Tinned Copper
    Braid Coverage: 40 % nom.
    Total number of wires: 8
    Outer Jacket Color: Black - or per request
    Marking: Teldor Standard, Per request
    Standards
    Standards: IEC 61156, ISO/IEC 11801, RoHS 2002/95/EC
    Flamability Rating: IEC 60332-1
    Performance
    Electrical Properties:  
    Cat. 7 Work Area Cables*
     

    Freq.

    MHz

    Attenuation
    dB/100m
    20oC

    PS NEXT Loss
    dB

    NEXT Loss
    dB

    RL
    dB

    PS ANEXT
    dB
    PS ELFEXT
    dB
    ELFEXT
    dB
    Typical
    Value 

    Cat. 7

    Typical Value 

    Cat. 7

    Typical Value 

    Cat. 7

    Typical Value 

    Cat. 7

    Typical Value 

    Cat. 7

    Typical Value 

    Cat. 7

    Typical Value 

    Cat. 7

    1

    2.9

    3.0

    105.0

    99.4

    108.0

    102.4

    22.0

    20.0

    68.0

    N/A

    95.0

    75.0

    98.0

    78.0

    4

    5.4

    5.6

    98.0

    90.4

    101.0

    93.4

    25.0

    23.0

    68.0

    N/A

    90.0

    75.0

    93.0

    78.0

    10

    8.5

    8.8

    95.0

    84.4

    98.0

    87.4

    28.0

    25.0

    68.0

    N/A

    86.0

    71.0

    89.0

    74.0

    20

    12.1

    12.4

    90.0

    80.0

    93.0

    83.0

    28.0

    25.0

    68.0

    N/A

    80.0

    65.0

    83.0

    68.0

    30

    14.8

    15.3

    85.0

    77.2

    88.0

    80.2

    27.0

    23.8

    68.0

    N/A

    76.0

    61.5

    79.0

    64.5

    100

    27.7

    28.5

    80.0

    69.4

    83.0

    72.4

    24.0

    21.1

    68.0

    N/A

    66.0

    51.0

    69.0

    54.0

    150

    34.3

    35.3

    78.0

    66.7

    81.0

    69.7

    22.0

    18.8

    65.0

    N/A

    63.0

    47.5

    66.0

    50.5

    200

    40.0

    41.2

    78.0

    65.0

    81.0

    68.0

    21.0

    18.0

    65.0

    N/A

    60.0

    45.0

    63.0

    48.0

    250

    45.1

    46.5

    75.0

    63.4

    78.0

    66.4

    20.0

    17.3

    62.0

    N/A

    58.0

    43.0

    61.0

    46.0

    300

    49.7

    51.3

    75.0

    62.2

    78.0

    65.2

    19.0

    17.3

    62.0

    N/A

    52.0

    41.5

    55.0

    44.5

    400

    58.2

    60.0

    70.0

    60.4

    73.0

    63.4

    19.0

    17.3

    62.0

    N/A

    49.0

    38.9

    52.0

    41.9

    500

    65.8

    67.9

    70.0

    58.9

    73.0

    61.9

    19.0

    17.3

    62.0

    N/A

    47.0

    37.0

    50.0

    40.0

    600

    72.9

    75.1

    70.0

    57.7

    73.0

    60.7

    19.0

    17.3

    62.0

    N/A

    45.0

    35.4

    48.0

    38.4


    *Supplied cables meet the minimum Cat. 7 transmission requirements as per IEC 61156-6 Ed. 2

     
    Frequency Range: 1 - 600 MHz
    Impedance: 100 Ω
    Coupling Attenuation: Type I
    DC Resistance: 145 Ω/km nom.
    Max. Resistance Unbalance: 2 %
    Capacitance Unbalance: 1.2 pF/m max.
    Velocity of Propagation: 80 % nom.
    Propagation Delay Skew: 20 ns/100m max.
    Dielectric Strength: 700 V/minute
    Dielectric Strength to Shield: 700 V/minute
    Min. Insulation Resistance : 5 GΩ•km
    Max. Tensile Strength - Short Term: 150 N
    Min. Bend Radius: 35 mm
    Max. Operating Temperature: +70 °C
    Min. Operating Temperature: –40 °C