Special TPE-E/PUR adapted to
DIN VDE 0250 / DIN VDE 0285-525-1 /
DIN EN 50525-1 Temperature range
flexing -30°C to +80°C
fixed installation -40°C to +80°C
Nominal voltage
up to 0,34 mm² 350 V (operating peak
voltage)
from 0,5 mm² U0/U 300/500 V
Test voltage
up to 0,34 mm² 1,5 kV, 5 minutes
from 0,5 mm² 3,0 kV, 5 minutes
Bare copper, stranded to DIN VDE 0295
and IEC 60228, fine or extra fine wires,
cl.5 or cl.6, BS 6360 cl.5 or 6, up to
0,34 mm² cl.5, above 0,5 mm² cl.6
Special core insulation, PP
Cores coded
up to 0,34 mm² according DIN 47100
above 0,5 mm² black cores with
continuous white numbering acc. to
DIN VDE 0293
GN-YE conductor, 3 cores and above
in the outer layer
Cores stranded in layers with
optimal lay-length
Special separating foil
Cable structure C-type, cu-screen of helically
wound, approx. 85-95% coverage
Outher sheath, special polyurethane
Sheath colour black (RAL 9005)
with meter marking
Properties
High flexibility at low temperatures
High abrasion resistance
Loadable under torsion stress ±360°/meter
Low adhesion
Resistant to
Microbes and rotting
Oxygene and ozone
Vibrations
UV-radiation
Largely resistant to
Oil and fats resistant
AWG sizes are approximate equivalent
values. The actual cross-section is in mm²
Application
These special robotic control and signal cables specially designed for torsion and bending stresses in robots and connecting handling tools. EMC = Electromagnetic compatibillity
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
CE = The product is conformed with the EC Low-Voltage Directive 2006/95/EC.