    TelcoSafe® LIST 1, RHH/RHW/ST1, ROHS, Central Office Power Wire and Cable 中央辦公室電源線和電纜
    看原圖
    TELCOSAFE-LIST1

    TelcoSafe® LIST 1, UL44, RHH/RHW/ST1, ROHS, Central Office Power Wire and Cable 中央辦公室電源線和電纜

    Limited Smoke, Non-Halogenated Insulated, Silicone-Free, Lead-Free
    Meets European RoHS directive
    90°C Dry, 75°C Wet – 600 Volts DC or AC
    UL Listed RHH/RHW/ST1 and VW-1 (8 AWG and Larger)
    UL Listed “For CT Use” (1/0 AWG and Larger)
    CSA Listed AWM I A/B, 105°C, 1000 Volts, FT1, FT2
    FT4-ST1, -40°C, W75C
    Audited by Telcordia to all 33 requirements of GR-347-CORE
    Meets IEC including 60674 & 60332

    Scope

    This specification covers the construction requirements for limited smoke,
    non-halogenated Central Office Power Wire and Cable, insulated with a
    proprietary EVA Copolymer limited smoke, non-halogenated compound. UL
    listed Type RHH/RHW/ST1, for use in accordance with the National Electrical
    Code.
    The construction of the wire and cable is in accordance with Underwriters’
    Laboratories requirements and the requirements of CSA for the FT4/ST1
    flame/smoke test. Sizes 1/0 AWG and larger are UL “CT Use” (Cable Tray)
    rated.

    Construction

    Size (AWG OR KCMIL) Stranding Conductor Diameter (Inches) Insulation Min. Avg. Wall (mils) Nominal Insulation Diam. (Inches)
    14 solid .0641 45 .160
    12 solid .0808 45 .175
    14 7/.0242” .071 45 .165
    12 7/.0305” .090 45 .185
    10 7/.0385” .114 45 .210
    8 7/.0486” .143 60 .270
    6 7/.0612” .180 60 .305
    4 7/.0772” .227 60 .350
    2 7/.0974” .286 60 .410
    1 19/.0664” .332 80 .493
    1/0 19/.0745” .365 80 .530
    2/0 19/.0837” .411 80 .575
    4/0 19/.1055” .517 80 .680
    350 37/.0973” .667 95 .860
    500 37/.1162” .797 95 .990
    750 61/.1109” .978 110 1.200
    1000 61/.1280″ 1.134 110 1.370

    Size: 14 AWG Through 1000 KCMIL – Single Conductor

    Conductors: Class B concentric stranded or solid, tinned copper conforming to ASTM B-8 or B-3 and B-33 and Underwriters’ Laboratories requirements.  An opaque mylar tape shall be applied over the conductor to facilitate stripping.

    Insulation: Black EVA Copolymer limited smoke, non-halogen, lead-free compound conforming to Underwriters’ Laboratories Standard 44, Subjects 509 and 758, and CSA C22.2 No. 210-2-M90.  The insulation has a limiting oxygen index (L.O.I.) minimum of 28%.  Other colors can be furnished upon request.

    Surface Marking:Two sides of the cable shall be printed using an ink of contrasting color and
    with the following information:

    “SOUTHWIRE AIW™ CORD BRAND TELCOSAFE® L1 NON-HAL (UL) E18321
    SIZE AWG 600 VOLTS RHH OR RHW/ST/1 FT4/IEEE1202 SR — LL90458 CSA
    AWM I A/B 105°C 1000 VOLTS W75C -40°C FT1, FT2, FT4-ST1 (YEAR of MFG)
    — MEETS IEC INCLUDING 60674 & 60332 — (SEQ. FOOTAGE. ON 1 SIDE)”

    For Sizes 1/0 AWG and larger add, “FOR CT USE” before “(UL)”
    For Sizes 8 AWG and larger add, “VW-1” after “(UL)”

    Testing: Physical and electrical tests in accordance with the requirements of UL Standard 44, Subject 509 and 758, and CSA Standard C22.2 No. 210.2-M90 as AWM.