1. Beden- Computer Cables for EIA RS-232 EIA RS-422 & RS-485 多對型隔離電腦儀表監控電纜
    Beden-Paired Audio Control and Instrumentation Cables 多對型声音音響通訊儀表監控電纜
    Belden -(Awg 20-16) Audio Control and Instrumentation Cable
    Belden -(Awg 20-18) Audio Control and Instrumentation Cable
    Belden -(Awg 22) Audio Control and Instrumentation Cable
    Belden- Plenum-Rated Audio Control and Instrumentation Cables 鐵氟龍耐燃多芯對隔離電纜
    Belden® Molded Cable Assemblies 電纜接頭一體成型組裝
    Belden-Antenna Rotor Control Cable and Duplex Primary Wire
    Belden-Armor Cable(Metal-sheathed) 金屬鎧裝電纜
    Belden-Control Cable – Multi-Core-APCXC and 19APCXC 控制電纜
    Belden-Low-Capacitance Computer Cable for EIA RS-232 and EIA RS-423 Applications
    Belden-MIL-W-16878(Type B) Conductors Shielded and Jacketed Communication and Instrumentation Cable
    Belden - Audio Control and Instrumentation Cable 声音音響 通訊 儀表控制電纜
    Belden - Unshielded Audio Control and Instrumentation Cable 声音音響 通訊 儀表控制電纜
    回上一頁
  2. 產品搜尋
    分 類:
    關鍵字:  

    首頁 > > Belden -(Awg 22) Audio Control and Instrumentation Cable

    Belden-88444  22 AWG x 4C,  FEP - FEP jacket. Plenum 4芯鐵氟龍CMP級声音音響, 通訊, 儀表控制電纜
    看原圖
    5165729




    商品編號: Belden-88444

    Belden-88444 22 AWG x 4C, FEP - FEP jacket. Plenum 4芯鐵氟龍CMP級声音音響, 通訊, 儀表控制電纜


    Unshielded
    Audio, Control and Instrumentation Cables
    Plenum-Rated and Non-Plenum

    22 AWG Stranded (7x30) Tinned Copper Conductors • Conductors Cabled (continued)
    PVC Insulation • Chrome PVC Jacket
    UL AWM Style 2576

    Belden-8457 NEC: 12C (150V 80°C) CMG Chart 1 CMG FT4 Section
    Belden-8458 NEC: 15C CMG Chart 2R CMG FT4 Section
    Belden-9431 NEC: 20C CMG Chart 2R CMG FT4 Section
    Belden-8459 NEC: 25C CMG Chart 2R CMG FT4 Section
    Belden-9432 NEC: 30C CMG Chart 2R CMG FT4 Section
    Belden-9433 NEC: 40C CMG Chart 2R CMG FT4 Section
    Belden-9434 NEC: 50C CMG Chart 2R CMG FT4 Section
     

    Plenum • FEP Insulation • Red FEP Jacket
    300V RMS, Non-conduit

    Belden-88442* NEC: 2C CMP FT6 300V RMS, Non-conduit

    Belden-88444 NEC: 4C CMP FT6
    Suitable for Outdoor and Direct Burial applications.
     

    Plenum • FEP Insulation • Natural Flamarrest® Jacket
    300V RMS, Non-conduit

    Belden-82442* NEC: 2C CMP FT6 300V RMS, Non-conduit

    Belden-82444 NEC: 4C CMP FT6 Green




    ★★★★商品說明★★★★

    88444
      Multi-Conductor - Audio, Control and Instrumentation Cable
    22 AWG stranded (7x30) TC conductors, conductors cabled, FEP insulation, FEP jacket.
    For more Information
    please call

    1-800-Belden1
    Put Ups and Colors:
    Item #PutupShip WeightColorNotesItem Desc
    88444 002100 100 FT2.900 LBRED C 4#22 FEP FEP
    88444 0021000 1,000 FT15.000 LBRED C 4#22 FEP FEP
    88444 002500 500 FT9.000 LBRED C 4#22 FEP FEP
    Notes: 
    C = CRATE REEL PUT-UP.
     
    Physical Characteristics (Overall)
    Conductor
    AWG:
    # ConductorsAWGStrandingConductor Material
    4227x30TC - Tinned Copper
    Insulation
    Insulation Material:
    Insulation MaterialWall Thickness (in.)
    FEP - Fluorinated Ethylene Propylene.006
    Outer Shield
    Outer Shield Material:
    Outer Shield Material
    Unshielded
    Outer Jacket
    Outer Jacket Material:
    Outer Jacket MaterialNom. Wall Thickness (in.)
    FEP - Fluorinated Ethylene Propylene.010
    Overall Cabling
    Overall Cabling Color Code Chart:
    NumberColor
    1Black
    2White
    3Red
    4Green
    Overall Nominal Diameter:0.121 in.
    Mechanical Characteristics (Overall)
    Operating Temperature Range:-70°C To +200°C
    Bulk Cable Weight:14.600 lbs/1000 ft.
    Max. Recommended Pulling Tension:36 lbs.
    Min. Bend Radius (Install)/Minor Axis:1.500 in.
    Applicable Specifications and Agency Compliance (Overall)
    Applicable Standards & Environmental Programs
    NEC/(UL) Specification:CMP
    CEC/C(UL) Specification:CMP
    EU CE Mark:Yes
    EU Directive 2000/53/EC (ELV):Yes
    EU Directive 2002/95/EC (RoHS):Yes
    EU RoHS Compliance Date (mm/dd/yyyy):04/01/2005
    EU Directive 2002/96/EC (WEEE):Yes
    EU Directive 2003/11/EC (BFR):Yes
    CA Prop 65 (CJ for Wire & Cable):Yes
    MII Order #39 (China RoHS):Yes
    Flame Test
    UL Flame Test:NFPA 262
    C(UL) Flame Test:FT6
    Suitability
    Suitability - Outdoor:Yes
    Suitability - Burial:Yes
    Plenum/Non-Plenum
    Plenum (Y/N):Yes
    Non-Plenum Number:8444
    Electrical Characteristics (Overall)
    Nom. Inductance:
    Inductance (µH/ft)
    .15
    Nom. Capacitance Conductor to Conductor:
    Capacitance (pF/ft)
    18
    Nom. Conductor DC Resistance:
    DCR @ 20°C (Ohm/1000 ft)
    15
    Nominal Conductor Loop Resistance:
    Resistance @ 20°C (Ohm/1000 ft)
    30
    Max. Operating Voltage - UL:
    Voltage
    300 V RMS
    Max. Recommended Current:
    Current
    3.3 Amps per conductor @ 25°C (10°C rise in temp)


    ★★★★商品規格描述★★★★

    Introduction

    Belden® multi-conductor cables are manufactured in a wide
    variety of gage sizes, dimensions, insulation materials, shielding
    configurations, and jacketing materials including Plenum and
    High-Temperature versions. These cables meet the technical
    requirements of many different types of systems. In fact, Belden
    offers one of the broadest lines of UL Listed, NEC and CEC
    multi-conductor cables available from any single source.
     

    Applications for multi-conductor cables include computers,
    communications, instrumentation, sound, control, audio, and
    data transmission. Each of these cables is designed to protect
    signal integrity under critical conditions by reducing hum, noise,
    and crosstalk.
     

    To assist you in selecting the proper cable for your application,
    both the suggested working voltages and the maximum temperature
    ratings are indicated for each applicable product in this section.
     

    Most of our multi-conductor cables are available from stock. Many
    of these are available off the shelf from distributors. If you have a
    new or unusual application or you cannot find a multi-conductor
    cable in this catalog section that meets your technical requirements,
    contact Technical Support at 1-800-BELDEN-1.
     

    Multi-Conductor Cables Packaging
    Belden’s unique UnReel® cable dispenser is available for many of
    the multi-conductor products listed in this section. The letter “U”
    before the specified put-up length denotes UnReel packaging