    EPR/CPE or CSPE 2,400 V 90°C 1C UL Listed Type MV-90 EPR/CPE高壓電力電纜
    看原圖
    5264886

    商品編號: A-3DC-0601

    EPR/CPE or CSPE 2,400 V 90°C 1C UL Listed Type MV-90 EPR/CPE高壓電力電纜
     

    For use in power circuits up to 2,400 V where shields cannot be properly terminated and where space is limited. Cable is used for power applications in chemical plants,
    refineries, steel mills, industrial plants, utility substations and generating stations. Ideally suited for applications where increased durability is required.

    Power Cable
    2,400 V Single Conductor - Nonshielded

    EPR/CPE or CSPE

    EPR insulation
    CPE or CSPE jacket
    Nonshielded
    UL Listed Type MV-90


    SPECIFICATIONS
    1. CONDUCTOR:
    Class B stranded, annealed, bare copper per ASTM B-3 and B-8, strand shield is an extruded semiconducting compound per ICEA S-96-659 (NEMA WC71)
    2. INSULATION:Ethylene Propylene Rubber (EPR) which meets or exceeds ICEA S-96-659 and UL 1072. For wet or dry locations per UL 1072 and NEC Article 328
    3. OVERALL JACKET: CPE or CSPE
    4. STANDARDS: Listed Type MV-90 per UL 1072 for wet and dry locations. Meets requirements of ICEA S-96-659 (NEMA WC71). Sizes 1/0 and larger marked Sunlight Resistant and
    pass IEEE 383 70,000 Btu/hr flame test and are marked "for CT use"
    5. AMPACITY:Based on three single conductor cables in isolated conduit in air per NEC Table 310.73 with a conductor temperature of 90°C and an ambient temperature of 40°C
    6. TEMPERATURE: 90°C
    7. VOLTAGE: 2,400 V


    APPLICATIONS
    For use in power circuits up to 2,400 V where shields cannot be properly terminated and where space is limited. Cable is used for power applications in chemical plants,
    refineries, steel mills, industrial plants, utility substations and generating stations. Ideally suited for applications where increased durability is required.