1. CCI- IRRIGATION CONTROL & COMMUNICATION CABLE 灌溉(防水)控制和通信電纜
    CCI- Alarm/Fire/Sound/Security PLENUM 火災警報系統 安全監控用線
    CCI- Alarm/Fire/Sound/Security 火災警報系統 安全監控用線
    CCI- Industrial Power 工業動力線
    CCI- MULTI-CONDUCTOR PLENUM SHIELDED 多芯隔離 影音 呼叫系統 安全監控用線
    CCI-IMSA Traffic Signal Cable 公共工程號誌信號傳輸纜線
    CCI-Portable Cables 輕便電纜
    回上一頁
  2. 產品搜尋
    分 類:
    關鍵字:  

    首頁 > > CCI- Alarm/Fire/Sound/Security PLENUM 火災警報系統 安全監控用線

    CCI-81404 Fire Alarm 14/4 SOLID BC FPLP Cables – Unshielded – Plenum Type FPLP Awg14x 4C 低煙型火災警報訊號傳輸線
    看原圖
    5553116




    商品編號: CCI-81404

    CCI-81404 Fire Alarm 14/4 SOLID BC FPLP Cables – Unshielded – Plenum Type FPLP Awg14x 4C 低煙型火災警報訊號傳輸線


      81404 - 14/4 SOLID BC FPLP
    FIRE ALARM NON-SHIELDED PLENUM Fire Alarm Multi-Conductor Cables – Unshielded – Plenum Type FPLP

    Features:

    • Low Smoke PVC jacket

       

    • Temperature rating 75°C

       

    • High speed dispensing system (pullout boxes)

       

    Applications:

    • Power limited fire alarm and communications cable for plenum applications.
    • Fire alarm, smoke detectors, signaling, fire protective circuits.

    Industry Approvals:

    • UL Type FPLP
    • NEC Article 760
    • cUL Type CMP/FT6
    • California State Fire Marshall



    ★★★★商品說明★★★★

    PART NUMBER

    PART NUMBER: 81404

    DESCRIPTION: 14/4 SOLID FPLP FT6 CABLE

    CONSTRUCTION: This cable consists of two bare copper insulated conductors and an overall jacket.

    APPROVALS: UL Standard 1424, NEC Article 760.

    APPLICATION: Fire Alarm Power Limited Circuit Cable Used in Plenum Applications

     

    Construction Parameters:

    Conductor: 14 AWG Bare Copper

    Stranding: Solid

    Insulation MaterialLow Smoke PVC

    Insulation Thickness0.008 Nom.

    Insulated Conductor Diameter0.080 Nom.

    Number of Conductors:  4

    Lay Length:  5.00" Nom.

    Jacket MaterialLow Smoke PVC

    Jacket Thickness0.017 Nom.

    Overall Cable Diameter0.227 Nom.

    Approximate Cable Weight:  65.0 Lbs/1M Nom.

    Flame RatingNFPA 262 Steiner Tunnel Smoke and Flame Test

     

    Electrical Properties:

    Temperature Rating-20to 75

    Operating Voltage300V RMS Max

    Capacitance Between Conductors@1KHz44Pf/ft Nom.

    Capacitance Between Conductors to shield@1KHz----

    DC Resistance per Conductor@20度: 2.54 Ohms/1M*Nom.

     

    Insulation ColorsBlack Red Green Yellow

    Jacket ColorsRed (other colors available for min order)

    Legend (Surface Ink Print):  COLEMAN CABLE 81404 14 AWG 4/C C(ETL)US-TYPE FPLP 75C