| 商品編號: BD-1694SB
RG-6 SDI/HDTV Shipboard Precision Video Cable - Analog/Digital 低煙無鹵適船舶高頻低損耗高畫質高清電視數位類比訊號傳輸同軸電纜 |
| |
| | |
玉山 / 台新 / 華南 / 萬泰 / 兆豐 / 遠東 / 新光 / 永豐 / 第一 / 彰化 / 合庫 / 日盛 / 匯豐 / 渣打國泰世華 / 台北富邦 / 大眾銀行 / 台灣中小企銀/台中商銀 / 澳盛銀行
| |
| | |
| | 1694SB
 | | Coax - Shipboard Precision Video Cable - Analog/Digital Application 18 AWG solid .040" bare copper conductor, gas-injected foam HDPE insulation, Duofoil® (100% coverage) plus a tinned copper braid shield (95% coverage), LSZH jacket. | For more Information please call
1-800-Belden1 |
Click here for Certificate Item # | Putup | Ship Weight | Color | Notes | Item Desc | 1694SB 0101000 | 1,000 FT | 46.000 LB | BLACK | C | #18 PE/GIFHDPE SH FRNHPO |
|
Notes: | | C = CRATE REEL PUT-UP. |
Usage (Overall) Suitable Applications: | Coaxial Cable for Communication, Audio, Video, CCTV, CATV, MATV, Broadband, or Broadcast use in Marine Shipboard and Offshore use |
Physical Characteristics (Overall) Conductor AWG: # Coax | AWG | Stranding | Conductor Material | Dia. (in.) | 1 | 18 | Solid | BC - Bare Copper | .040 |
|
Total Number of Conductors: | 1 |
Insulation Insulation Material: Insulation Material | Dia. (in.) | Gas-injected FHDPE - Foam High Density Polyethylene | .180 |
|
Outer Shield Outer Shield Material: Layer # | Outer Shield Trade Name | Type | Outer Shield Material | Coverage (%) | 1 | Duofoil® | Tape | Aluminum Foil-Polyester Tape-Aluminum Foil | 100 | 2 | | Braid | TC - Tinned Copper | 95 |
|
Outer Jacket Outer Jacket Material: Outer Jacket Material | LSZH - Low Smoke Zero Halogen |
|
Overall Cable Overall Nominal Diameter: | 0.274 in. |
Mechanical Characteristics (Overall) Operating Temperature Range: | -30°C To +75°C |
Bulk Cable Weight: | 42 lbs/1000 ft. |
Max. Recommended Pulling Tension: | 69 lbs. |
Min. Bend Radius/Minor Axis: | 2.750 in. |
Applicable Specifications and Agency Compliance (Overall) Applicable Standards & Environmental Programs NEC/(UL) Specification: | CMG-LS |
CEC/C(UL) Specification: | CMG-LS |
EU Directive 2011/65/EU (ROHS II): | Yes |
IEEE Specification: | Std. 45 clause 23 |
EU Directive 2000/53/EC (ELV): | Yes |
EU Directive 2002/95/EC (RoHS): | Yes |
EU RoHS Compliance Date (mm/dd/yyyy): | 08/01/2005 |
EU Directive 2002/96/EC (WEEE): | Yes |
EU Directive 2003/11/EC (BFR): | Yes |
CA Prop 65 (CJ for Wire & Cable): | Yes |
MII Order #39 (China RoHS): | Yes |
Other Specification: | UL444, ABS Type Approval Certificate 05-HS500072C |
Flame Test UL Flame Test: | UL1685 FT4 Loading, Limited Smoke |
IEC Flame Test: | 60332-1, 60332-3-22 (Category A) |
Suitability Suitability - Outdoor: | Yes |
Electrical Characteristics (Overall) Nom. Characteristic Impedance: Nom. Inductance: Nom. Capacitance Conductor to Shield: Nominal Velocity of Propagation: Nominal Delay: Nom. Conductor DC Resistance: DCR @ 20°C (Ohm/1000 ft) | 6.4 |
|
Nominal Outer Shield DC Resistance: DCR @ 20°C (Ohm/1000 ft) | 2.8 |
|
Nom. Attenuation: Freq. (MHz) | Attenuation (dB/100 ft.) | 1.000 | 0.240 | 3.580 | 0.440 | 5.000 | 0.520 | 7.000 | 0.610 | 10.000 | 0.710 | 67.500 | 1.650 | 71.500 | 1.690 | 88.500 | 1.860 | 100.000 | 1.950 | 135.000 | 2.240 | 143.000 | 2.300 | 180.000 | 2.570 | 270.000 | 3.170 | 360.000 | 3.690 | 540.000 | 4.600 | 720.000 | 5.380 | 750.000 | 5.500 | 1000.000 | 6.420 | 1500.000 | 7.990 | 2000.000 | 9.370 | 2250.000 | 10.010 | 3000.000 | 11.780 | 4500.000 | 14.920 |
|
Max. Operating Voltage - UL: Other Electrical Characteristic 1: | Impedance tested in accordance with ASTM D-4566 paragraph 43.2, option 2 using a 75 Ohm fixed bridge and termination. 75 +/- 1.5 Ohms |
Other Electrical Characteristic 2: | Return Loss tested in accordance with ASTM D-4566 paragraph 45.3, using a 75 Ohm fixed bridge and termination. |
Minimum Return Loss: Start Freq. (MHz) | Stop Freq. (MHz) | Min. RL (dB) | 5 | 1600 | 23 | 1600 | 4500 | 21 |
|
Sweep Test Sweep Testing: | 100% Sweep tested 5 MHz to 4.5 GHz. |