7893A
 | | Multi-Conductor - Multi-Pair Cable 26 AWG stranded tinned copper conductor, Datalene® insulation, pairs individually shielded with bonded Beldfoil® with a drain wire and have numbered and color-coded PVC jackets, overall Beldfoil® shield/drain wire + overall PVC jacket with nylon rip cord | For more Information please call
1-800-Belden1 |
Click here for Certificate
Item # | Putup | Ship Weight | Color | Notes | Item Desc | 7893A Z4B1000 | 1,000 FT | 240.000 LB | VIO Z4B | C | 16 #26 FHDPE FSPR PVC FS PVC |
|
Notes: | |
C = CRATE REEL PUT-UP. |
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs | AWG | Stranding | Conductor Material | Dia. (in.) | 16 | 26 | 7x34 | TC - Tinned Copper | .019 |
|
Total Number of Conductors: | 32 |
Insulation
Insulation Material:
Insulation Trade Name | Insulation Material | Dia. (in.) | Datalene® | FHDPE - Foam High Density Polyethylene | .054 |
|
Inner Shield
Inner Shield Material:
Inner Shield Trade Name | Type | Inner Shield Material | Coverage (%) | Beldfoil® | Tape | Bonded Aluminum Foil-Polyester Tape | 100 |
|
Inner Shield Drain Wire AWG:
Inner Shield Drain Wire Stranding: | Stranded |
Inner Shield Drain Wire Conductor Material: | TC - Tinned Copper |
Inner Jacket
Inner Jacket Material:
Inner Jacket Material | Nom. Dia. (in.) | PVC - Polyvinyl Chloride | .136 |
|
Inner Jacket Color Code Chart:
Number | Color | 1 | Brown and Numbered 1 | 2 | Red and Numbered 2 | 3 | Orange and Numbered 3 | 4 | Yellow and Numbered 4 | 5 | Green and Numbered 5 | 6 | Blue and Numbered 6 | 7 | Purple and Numbered 7 | 8 | Gray and Numbered 8 | 9 | White and Numbered 9 | 10 | Black and Numbered 10 | 11 | Tan and Numbered 11 | 12 | Pink and Numbered 12 | 13 | Gray/Brown Stripe and Numbered 13 | 14 | Gray/Red Stripe and Numbered 14 | 15 | Gray/Orange Stripe and Numbered 15 | 16 | Gray/Yellow Stripe and Numbered 16 |
|
Outer Shield
Outer Shield Material:
Outer Shield Trade Name | Type | Outer Shield Material | Coverage (%) | Beldfoil® | Tape | Aluminum Foil-Polyester Tape | 100 |
|
Outer Shield Drain Wire AWG:
AWG | Stranding | Drain Wire Conductor Material | 26 | Stranded | TC - Tinned Copper |
|
Outer Jacket
Outer Jacket Material:
Outer Jacket Material | PVC - Polyvinyl Chloride |
|
Overall Cable
Overall Nominal Diameter: | 0.770 in. |
Pair
Pair Color Code Chart:
Number | Color | 1 | Red & Black | 2 | Red & Black | 3 | Red & Black | 4 | Red & Black | 5 | Red & Black | 6 | Red & Black | 7 | Red & Black | 8 | Red & Black | 9 | Red & Black | 10 | Red & Black | 11 | Red & Black | 12 | Red & Black | 13 | Red & Black | 14 | Red & Black | 15 | Red & Black | 16 | Red & Black |
|
Pair Lay Length & Direction:
Mechanical Characteristics (Overall)
Operating Temperature Range: | -30°C To +80°C |
Bulk Cable Weight: | 198 lbs/1000 ft. |
Max. Recommended Pulling Tension: | 171 lbs. |
Min. Bend Radius/Minor Axis: | 7.750 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: | CM |
CEC/C(UL) Specification: | CM |
EU Directive 2000/53/EC (ELV): | Yes |
EU Directive 2002/95/EC (RoHS): | Yes |
EU RoHS Compliance Date (mm/dd/yyyy): | 01/01/2004 |
EU Directive 2002/96/EC (WEEE): | Yes |
EU Directive 2003/11/EC (BFR): | Yes |
CA Prop 65 (CJ for Wire & Cable): | Yes |
MII Order #39 (China RoHS): | Yes |
Flame Test
UL Flame Test: | UL1685 UL Loading |
Plenum/Non-Plenum
Surface Printing (Overall)
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Nom. Inductance:
Nom. Capacitance Conductor to Conductor:
Nom. Capacitance Cond. to Other Conductor & Shield:
Nominal Velocity of Propagation:
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft) | 37.3 |
|
Ind. Pair Nominal Shield DC Resistance @ 20 Deg. C: | 25.500 Ohm/1000 ft |
Nom. Attenuation:
Freq. (MHz) | Attenuation (dB/100 ft.) | .384 | .84 | .7056 | 1.14 | .768 | 1.18 | 1.024 | 1.34 | 1.4112 | 1.50 | 1.536 | 1.54 | 2.048 | 1.69 | 2.8224 | 1.86 | 3.0720 | 1.92 | 4.096 | 2.14 | 5.6448 | 2.40 | 6.144 | 2.47 | 8.192 | 2.75 | 11.2896 | 3.09 | 12.288 | 3.18 | 24.576 | 4.20 |
|
Notes (Overall)
Notes: | Pair jackets and shields are bonded so both strip simultaneously with automatic stripping equipment. Datalene® insulation features include low dielectric constant and a dissipation factor for high-speed, low-distortion data handling. Physical properties include good crush resistance and light weight. |
Test Reports
a) UL
i) UL Test Reports are available on-line through the UL Client Document Access web portal.
ii) UL Inspection Reports are also available through the UL Client Document Access web portal.
b) CSA
i) CSA "Descriptive Report and Test Results" documents are available on the CSA Gateway Portal.
ii) CSA Inspection Reports are maintained on the CSA issued flash drive at each manufacturing location.
* other test data may be available if requested at time of order.