| 商品編號: Belden9907
9907 Coax - Coaxial Cable - Thinnet 10Base2 Ethernet
20 AWG stranded (19x32) .037" tinned copper conductor, foam polyethylene insulation, Duobond® II (100% coverage) plus an overall tinned copper braid shield (93% coverage), PVC jacket. |
| |
| | |
玉山 / 台新 / 華南 / 萬泰 / 兆豐 / 遠東 / 新光 / 永豐 / 第一 / 彰化 / 合庫 / 日盛 / 匯豐 / 渣打國泰世華 / 台北富邦 / 大眾銀行 / 台灣中小企銀/台中商銀 / 澳盛銀行
| |
| | |
| | DESCRIPTION: 20 AWG stranded (19x32) .037" tinned copper conductor, foam polyethylene insulation, Duobond® II (100% coverage) plus an overall tinned copper braid shield (93% coverage), PVC jacket. SUITABLE APPLICATIONS : Suitable Applications: Thin Ethernet PHYSICAL CHARACTERISTICS : CONDUCTOR : Number of Coax: 1 Total Number of Conductors: 1 RG Type: 58A/U AWG: 20 Stranding: 19x32 Conductor Diameter: .037 in. Conductor Material: TC - Tinned Copper INSULATION : Insulation Material: FHDPE - Foam High Density Polyethylene Insulation Diameter: .102 in. OUTER SHIELD : Outer Shield Material Trade Name: Duobond® II Outer Shield Type: Tape/Braid Outer Shield Material: Layer Number Trade Name Type Material % Coverage (%) 1 Bonded Duofoil® Tape Bonded Aluminum Foil-Polyester Tape-Aluminum Foil 100 2 Braid TC - Tinned Copper 93 Outer Shield %Coverage: 100 % OUTER JACKET : Outer Jacket Material: PVC - Polyvinyl Chloride OVERALL NOMINAL DIAMETER : Overall Nominal Diameter: .185 in. MECHANICAL CHARACTERISTICS : Operating Temperature Range: -40°C To +80°C UL Temperature Rating: 60°C (UL AWM Style 1354) Bulk Cable Weight: 22.3 lbs/1000 ft. Max. Recommended Pulling Tension: 45 lbs. Min. Bend Radius (Install): 1.8 in. APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE : APPLICABLE STANDARDS : NEC/(UL) Specification: CM, CL2 CEC/C(UL) Specification: CM AWM Specification: UL Style 1354 (30 V 60°C) IEEE Specification: IEEE802.3 10Base2 IEC Specification: ISO8802.3 10Base2 EU CE Mark (Y/N): Yes EU RoHS Compliant (Y/N): Yes EU RoHS Compliance Date (mm/dd/yyyy):: 01/01/2004 Customer Part Number Reference Specification: DEC Part No. 17-01248-00 FLAME TEST : UL Flame Test: UL1685 UL Loading PLENUM/NON-PLENUM : Plenum (Y/N): N Plenum Number: 82907, 89907 ELECTRICAL CHARACTERISTICS : Nom. Characteristic Impedance: 50 +/- 2 Ω Nom. Capacitance Conductor to Shield: 25.4 pF/ft Nominal Velocity of Propagation: 80 % Nominal Delay: 1.27 ns/ft Nom. Conductor DC Resistance @ 20 Deg. C: 8.8 Ω/1000 ft Nominal Outer Shield DC Resistance @ 20 Deg.C: 5.8 Ω/1000 ft Maximum Loop Resistance: 15.24 Ω/1000 ft Nom. Attenuation: Description Frequency (MHz) Start Frequency (MHz) Stop Frequency (MHz) Nom. Attenuation (dB/100 ft.) 1 .43 10 1.3 50 2.91 100 4.2 200 6.1 400 8.9 700 12.1 900 13.9 1000 14.8 Max. Operating Voltage - UL: 300 V RMS, 30 V RMS (UL AWM Style 1354) NOTES : Notes: Tape to bond at overlap area only. Tape is not designed to bond to dielectric core. PUT-UPS AND COLORS: Item Description Put-Up (ft.) Ship Weight (lbs.) Jacket Color Notes 9907 E4X1000 RG-58 TYPE COAX 1000 23 GRAY, LIGHT DEC C 9907 E4X1640 RG-58 TYPE COAX 1640 41 GRAY, LIGHT DEC C 9907 E4X2500 RG-58 TYPE COAX 2500 62.5 GRAY, LIGHT DEC C 9907 E4X3280 RG-58 TYPE COAX 3280 82 GRAY, LIGHT DEC C 9907 E4X500 RG-58 TYPE COAX 500 11.5 GRAY, LIGHT DEC 9907 E4XU1000 RG-58 TYPE COAX U1000 24 GRAY, LIGHT DEC
C = CRATE REEL PUT-UP.
|
| |
|
|