| 商品編號: Belden-89269
89269 Coax - 93 Ohm Coax
RG-62/U type, 22 AWG solid .025" bare copper-covered steel conductor, plenum, semi-solid FEP insulation, bare copper braid shield (94% coverage), FEP jacket. |
| |
| | |
玉山 / 台新 / 華南 / 萬泰 / 兆豐 / 遠東 / 新光 / 永豐 / 第一 / 彰化 / 合庫 / 日盛 / 匯豐 / 渣打國泰世華 / 台北富邦 / 大眾銀行 / 台灣中小企銀/台中商銀 / 澳盛銀行
| |
| | |
| | DESCRIPTION: RG-62/U type, 22 AWG solid .025" bare copper-covered steel conductor, plenum, semi-solid FEP insulation, bare copper braid shield (94% coverage), FEP jacket. PHYSICAL CHARACTERISTICS : CONDUCTOR : Number of Coax: 1 Total Number of Conductors: 1 RG Type: 62/U AWG: 22 Stranding: Solid Conductor Diameter: .025 in. Conductor Material: BCCS - Bare Copper Covered Steel INSULATION : Insulation Material Trade Name: Teflon® Insulation Material: Semi-Solid FEP - Semi-Solid Fluorinated Ethylene-Propylene Insulation Diameter: .142 in. OUTER SHIELD : Outer Shield Type: Braid Outer Shield Material: BC - Bare Copper Outer Shield %Coverage: 94 % OUTER JACKET : Outer Jacket Material: FEP - Fluorinated Ethylene Propylene OVERALL NOMINAL DIAMETER : Overall Nominal Diameter: .200 in. MECHANICAL CHARACTERISTICS : Operating Temperature Range: -70°C To +200°C UL Temperature Rating: 200°C Bulk Cable Weight: 33 lbs/1000 ft. Max. Recommended Pulling Tension: 84 lbs. Min. Bend Radius (Install): 2.5 in. APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE : APPLICABLE STANDARDS : NEC/(UL) Specification: CMP CEC/C(UL) Specification: CMP EU CE Mark (Y/N): No EU RoHS Compliant (Y/N): Yes EU RoHS Compliance Date (mm/dd/yyyy):: 04/01/2005 FLAME TEST : UL Flame Test: NFPA 262 C(UL) Flame Test: FT6 SUITABILITY : Suitability - Indoor: Yes Suitability - Outdoor: Yes Suitability - Burial: Yes PLENUM/NON-PLENUM : Plenum (Y/N): Y Non-Plenum Number: 9269 ELECTRICAL CHARACTERISTICS : Nom. Characteristic Impedance: 93 Ω Nom. Inductance: 0.111 µH/ft Nom. Capacitance Conductor to Shield: 12.8 pF/ft Nominal Velocity of Propagation: 85 % Nominal Delay: 1.197 ns/ft Nom. Conductor DC Resistance @ 20 Deg. C: 41.2 Ω/1000 ft Nominal Outer Shield DC Resistance @ 20 Deg.C: 3.4 Ω/1000 ft Nom. Attenuation: Description Frequency (MHz) Start Frequency (MHz) Stop Frequency (MHz) Nom. Attenuation (dB/100 ft.) 1 0.3 10 0.9 50 1.9 100 2.7 200 3.8 400 5.3 700 7.3 900 8.2 1000 8.7 Max. Operating Voltage - UL: 300 V RMS NOTES : Notes: Teflon® is a registered trademark of E. I. duPont de Nemours and Co. used under license by Belden, Inc.[ PUT-UPS AND COLORS: Item Description Put-Up (ft.) Ship Weight (lbs.) Jacket Color Notes 89269 0091000 #22 COAX FEP RG62A/U 1000 33 WHITE C 89269 009500 #22 COAX FEP RG62A/U 500 16.5 WHITE C 89269 010100 #22 COAX FEP RG62A/U 100 5.2 BLACK 89269 0101000 #22 COAX FEP RG62A/U 1000 33 BLACK C 89269 010500 #22 COAX FEP RG62A/U 500 16.5 BLACK C
C = CRATE REEL PUT-UP.
|
| |
|
|