| 商品編號: Belden89880
89880 Coax - Coaxial Cable - Thicknet 10Base5 Ethernet
12 AWG solid .086" bare copper conductor, foam FEP insulation, Duobond IV® quad shield (100% coverage), fluorocopolymer jacket. |
| |
| | |
玉山 / 台新 / 華南 / 萬泰 / 兆豐 / 遠東 / 新光 / 永豐 / 第一 / 彰化 / 合庫 / 日盛 / 匯豐 / 渣打國泰世華 / 台北富邦 / 大眾銀行 / 台灣中小企銀/台中商銀 / 澳盛銀行
| |
| | |
| | DESCRIPTION: 12 AWG solid .086" bare copper conductor, foam FEP insulation, Duobond IV® quad shield (100% coverage), fluorocopolymer jacket. SUITABLE APPLICATIONS : Suitable Applications: Thick Ethernet PHYSICAL CHARACTERISTICS : CONDUCTOR : Number of Coax: 1 Total Number of Conductors: 1 AWG: 12 Stranding: Solid Conductor Diameter: .086 in. Conductor Material: BC - Bare Copper INSULATION : Insulation Material: FFEP - Foam Fluorinated Ethylene Propylene Insulation Diameter: .245 in. OUTER SHIELD : Outer Shield Material Trade Name: Duobond® IV Outer Shield Type: Tape/Braid/Tape/Braid Outer Shield Material: Layer Number Trade Name Type Material % Coverage (%) 1 Bonded Duofoil® Tape Bonded Aluminum Foil-Polyester Tape-Aluminum Foil 100 2 Braid TC - Tinned Copper 90 3 Duofoil® Tape Aluminum Foil-Polyester Tape-Aluminum Foil 100 4 Braid TC - Tinned Copper 90 Outer Shield %Coverage: 100 % OUTER JACKET : Outer Jacket Material: PVDF - Fluorocopolymer OVERALL NOMINAL DIAMETER : Overall Nominal Diameter: .375 in. MECHANICAL CHARACTERISTICS : Operating Temperature Range: -25°C To +150°C UL Temperature Rating: 150°C Bulk Cable Weight: 137 lbs/1000 ft. Max. Recommended Pulling Tension: 255 lbs. Min. Bend Radius (Install): 6 in. APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE : APPLICABLE STANDARDS : NEC/(UL) Specification: CMP, CL2P CEC/C(UL) Specification: CMP IEEE Specification: IEEE802.3 10Base5 EU CE Mark (Y/N): Yes EU RoHS Compliant (Y/N): Yes EU RoHS Compliance Date (mm/dd/yyyy):: 04/01/2005 Customer Part Number Reference Specification: DEC Part No. 17-00324-00 FLAME TEST : UL Flame Test: NFPA 262 CSA Flame Test: FT6 SUITABILITY : Suitability - Outdoor: Yes Suitability - Burial: Yes PLENUM/NON-PLENUM : Plenum (Y/N): Y Non-Plenum Number: 9880 ELECTRICAL CHARACTERISTICS : Nom. Characteristic Impedance: 50 +/- 2 Ω Nom. Inductance: .0645 µH/ft Nom. Capacitance Conductor to Shield: 26.0 pF/ft Nominal Velocity of Propagation: 78 % Nominal Delay: 1.30 ns/ft Nom. Conductor DC Resistance @ 20 Deg. C: 1.42 Ω/1000 ft Nominal Outer Shield DC Resistance @ 20 Deg.C: 1.52 Ω/1000 ft Nom. Attenuation: Description Frequency (MHz) Start Frequency (MHz) Stop Frequency (MHz) Nom. Attenuation (dB/100 ft.) 1 .18 5 .37 max 10 .52 max 50 1.15 100 1.65 200 2.45 400 3.8 700 5.6 900 6.8 1000 7.2 Max. Power Rating: Description Frequency (MHz) Start Frequency (MHz) Stop Frequency (MHz) Max. Power Rating (W) 1 15900 5 6928 10 4802 50 1992 100 1344 200 900 400 602 700 438 900 382 1000 361 Max. Operating Voltage - UL: 300 V RMS Max. Operating Voltage - Non-UL: 300 V RMS NOTES : Notes: Ring-band stripes every 2.5 meters to aid users in tap placement. PUT-UPS AND COLORS: Item Description Put-Up (ft.) Ship Weight (lbs.) Jacket Color Notes 89880 0031000 #11H FFEP SH SOL COAX 1000 134 ORANGE C 89880 0031640 #11H FFEP SH SOL COAX 1640 224.68 ORANGE C Z
C = CRATE REEL PUT-UP. Z = FINAL PUT-UP LENGTH MAY VARY (+ OR -) 10% FOR SPOOLS OR REELS AND (+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN.
|
| |
|
|