商品編號: Belden8219
8219 Coax - RG-58A/U Type
RG-58A/U type, 20 AWG stranded (19x32) .037" tinned copper conductor, foam polyethylene insulation, tinned copper braid shield (96% coverage), PVC jacket. |
|
|
|
|
|
玉山 / 台新 / 華南 / 萬泰 / 兆豐 / 遠東 / 新光 / 永豐 / 第一 / 彰化 / 合庫 / 日盛 / 匯豐 / 渣打國泰世華 / 台北富邦 / 大眾銀行 / 台灣中小企銀/台中商銀 / 澳盛銀行
|
|
|
|
|
|
|
DESCRIPTION:
RG-58A/U type, 20 AWG stranded (19x32) .037" tinned copper conductor, foam polyethylene insulation, tinned copper braid shield (96% coverage), PVC jacket.
PHYSICAL CHARACTERISTICS :
CONDUCTOR :
Number of Coax: 1
Total Number of Conductors: 1
RG Type: 58A/U
AWG: 20
Stranding: 19x32
Conductor Diameter: .037 in.
Conductor Material: TC - Tinned Copper
INSULATION :
Insulation Material: FPE - Foam Polyethylene
Insulation Diameter: .114 in.
OUTER SHIELD :
Outer Shield Type: Braid
Outer Shield Material: TC - Tinned Copper
Outer Shield %Coverage: 93 %
OUTER JACKET :
Outer Jacket Material: PVC - Polyvinyl Chloride
OVERALL NOMINAL DIAMETER :
Overall Nominal Diameter: .194 in.
MECHANICAL CHARACTERISTICS :
Operating Temperature Range: -40°C To +80°C
UL Temperature Rating: 80°C (UL AWM Style 1354)
Bulk Cable Weight: 25 lbs/1000 ft.
Max. Recommended Pulling Tension: 50 lbs.
Min. Bend Radius (Install): 2 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE :
APPLICABLE STANDARDS :
NEC/(UL) Specification: CM
CEC/C(UL) Specification: CM
AWM Specification: UL Style 1354 (30 V 80°C)
EU CE Mark (Y/N): Yes
EU RoHS Compliant (Y/N): Yes
EU RoHS Compliance Date (mm/dd/yyyy):: 01/01/2004
PMSHA Specification: SC-182/5
FLAME TEST :
UL Flame Test: UL1685 UL Loading
SUITABILITY :
Suitability - Indoor: Yes
Suitability - Outdoor: Yes - Black jacket only
Suitability - Aerial: Yes - Black jacket only - when supported by a messenger wire
PLENUM/NON-PLENUM :
Plenum (Y/N): N
ELECTRICAL CHARACTERISTICS :
Nom. Characteristic Impedance: 53.5 Ω
Nom. Inductance: 0.065 µH/ft
Nom. Capacitance Conductor to Shield: 26.5 pF/ft
Nominal Velocity of Propagation: 73 %
Nominal Delay: 1.39 ns/ft
Nom. Conductor DC Resistance @ 20 Deg. C: 8.8 Ω/1000 ft
Nominal Outer Shield DC Resistance @ 20 Deg.C: 4.1 Ω/1000 ft
Nom. Attenuation:
Description Frequency (MHz) Start Frequency (MHz) Stop Frequency (MHz) Nom. Attenuation (dB/100 ft.)
1 0.4
10 1.3
50 3.1
100 4.5
200 6.6
400 10.0
700 14.2
900 16.6
1000 18.1
Max. Operating Voltage - UL: 30 V RMS (UL AWM Style 1354), 300 V RMS (CM)
PUT-UPS AND COLORS:
Item Description Put-Up (ft.) Ship Weight (lbs.) Jacket Color Notes
8219 0091000 RG58A/U TYPE COAX 1000 26 WHITE C
8219 009U500 RG58A/U TYPE COAX U500 13.5 WHITE
8219 0101000 RG58A/U TYPE COAX 1000 26 BLACK C
8219 010500 RG58A/U TYPE COAX 500 13 BLACK C
8219 010U1000 RG58A/U TYPE COAX U1000 27 BLACK
8219 010U500 RG58A/U TYPE COAX U500 14 BLACK
C = CRATE REEL PUT-UP.
|
|
|
|
|