    Belden 9252  RG122/U  50 Ohm M17/157-00001 Coaxial PVCNC MIL軍規同軸電纜
    看原圖
    463408

    商品編號: Belden-9252

    Belden 9252  RG122/U  50 Ohm M17/157-00001 Coaxial PVCNC MIL軍規同軸電纜  

    22 AWG stranded (27x36) .030" tinned copper conductor, polyethylene insulation, tinned copper braid shield (95% coverage), non-contaminating PVC jacket.
     
    DESCRIPTION:
    22 AWG stranded (27x36) .030" tinned copper conductor, polyethylene insulation, tinned copper braid shield (95% coverage), non-contaminating PVC jacket.


    PHYSICAL CHARACTERISTICS :
    CONDUCTOR :
    Number of Coax: 1
    Total Number of Conductors: 1
    RG Type: 122/U
    AWG: 22
    Stranding: 27x36
    Conductor Diameter: .030 in.
    Conductor Material: TC - Tinned Copper

    INSULATION :
    Insulation Material: PE - Polyethylene
    Insulation Diameter: .096 in.

    OUTER SHIELD :
    Outer Shield Type: Braid
    Outer Shield Material: TC - Tinned Copper
    Outer Shield %Coverage: 95 %

    OUTER JACKET :
    Outer Jacket Material: PVCNC - Polyvinyl Chloride Non-Contaminating

    OVERALL NOMINAL DIAMETER :
    Overall Nominal Diameter: .160 in.
    MECHANICAL CHARACTERISTICS :

    Operating Temperature Range: -40°C To +80°C
    UL Temperature Rating: 80°C
    Bulk Cable Weight: 17 lbs/1000 ft.
    Max. Recommended Pulling Tension: 38 lbs.
    Min. Bend Radius (Install): 1.6 in.
    APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE :


    APPLICABLE STANDARDS :
    NEC/(UL) Specification: CMX
    CEC/C(UL) Specification: CMX
    AWM Specification: UL Style 1354 (30 V 80°C)
    EU CE Mark (Y/N): Yes
    EU RoHS Compliant (Y/N): Yes
    EU RoHS Compliance Date (mm/dd/yyyy):: 10/01/2005
    Military Specification: M17/157-00001

    FLAME TEST :
    UL Flame Test: UL1685 UL Loading, VW-1

    PLENUM/NON-PLENUM :
    Plenum (Y/N): N
    ELECTRICAL CHARACTERISTICS :

    Nom. Characteristic Impedance: 50 Ω
    Nom. Inductance: 0.077 µH/ft
    Nom. Capacitance Conductor to Shield: 30.8 pF/ft
    Nominal Velocity of Propagation: 66 %
    Nominal Delay: 1.54 ns/ft
    Nom. Conductor DC Resistance @ 20 Deg. C: 17.1 Ω/1000 ft
    Nominal Outer Shield DC Resistance @ 20 Deg.C: 5.2 Ω/1000 ft
    Nom. Attenuation:

    Description Frequency (MHz) Start Frequency (MHz) Stop Frequency (MHz) Nom. Attenuation (dB/100 ft.)
    1 0.4
    10 1.7
    50 4.5
    100 7.0
    200 11.0
    400 16.5
    700 23.5
    900 27.3
    1000 29.0


    Max. Operating Voltage - UL: 300 V RMS (CMX), 30 V RMS (UL AWM Style 1354)
    Max. Operating Voltage - Non-UL: 1100 V RMS
    Max. Operating Voltage - Other:

    Other Voltage Description
    Military Specification 1400 V RMS


    PUT-UPS AND COLORS:

    Item Description Put-Up (ft.) Ship Weight (lbs.) Jacket Color Notes
    9252 0101000 M17/157 MIL-C-17G 1000 18 BLACK