商品編號: Belden-9272, taiwan, google
Belden9272 Twinax - Twinaxial Cable 工業電腦數據傳輸電線
20 AWG stranded (7x28) .038" tinned copper conductors, polyethylene insulation, tinned copper braid shield (93% Coverage), PVC jacket.
DESCRIPTION:
20 AWG stranded (7x28) .038" tinned copper conductors, polyethylene insulation, tinned copper braid shield (93% Coverage), PVC jacket.
PHYSICAL CHARACTERISTICS :
CONDUCTOR :
Number of Pairs: 1
Total Number of Conductors: 2
AWG: 20
Stranding: 7x28
Conductor Diameter: .038 in.
Conductor Material: TC - Tinned Copper
INSULATION :
Insulation Material: PE - Polyethylene
PAIR :
Pair Lay Length & Direction:
Lay Length (in.) Direction Twists/ft (twist/ft)
4.1
Pair Diameter: .156 in.
Pair Color Code Chart:
Number Color
1 Clear & Blue
OUTER SHIELD :
Outer Shield Type: Braid
Outer Shield Material: TC - Tinned Copper
Outer Shield %Coverage: 93 %
OUTER JACKET :
Outer Jacket Material: PVC - Polyvinyl Chloride
OVERALL NOMINAL DIAMETER :
Overall Nominal Diameter: .244 in.
MECHANICAL CHARACTERISTICS :
Operating Temperature Range: -20°C To +60°C
UL Temperature Rating: 60°C (UL AWM Style 2092)
Bulk Cable Weight: 39 lbs/1000 ft.
Max. Recommended Pulling Tension: 68 lbs.
Min. Bend Radius (Install): 2.5 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE :
APPLICABLE STANDARDS :
NEC/(UL) Specification: CM
CEC/C(UL) Specification: CM
AWM Specification: UL Style 2092 (300 V 60°C)
EU CE Mark (Y/N): Yes
EU RoHS Compliant (Y/N): Yes
EU RoHS Compliance Date (mm/dd/yyyy):: 01/01/2004
FLAME TEST :
UL Flame Test: UL1685 UL Loading
PLENUM/NON-PLENUM :
Plenum (Y/N): N
Plenum Number: 89272
ELECTRICAL CHARACTERISTICS :
Nom. Characteristic Impedance: 78 Ω
Nom. Inductance: .020 µH/ft
Nom. Capacitance Conductor to Conductor @ 1 KHz: 19.7 pF/ft
Nominal Velocity of Propagation: 66 %
Nominal Delay: 1.54 ns/ft
Nom. Conductor DC Resistance @ 20 Deg. C: 9.5 Ω/1000 ft
Nominal Outer Shield DC Resistance: 3.4 Ω/1000 ft
Nom. Attenuation:
Description Frequency (MHz) Start Frequency (MHz) Stop Frequency (MHz) Nom. Attenuation (dB/100 ft.)
1 0.6
10 2.1
50 5.0
100 7.5
200 11.0
400 16.0
Max. Operating Voltage - UL: 300 V RMS (UL AWM Style 2092)
PUT-UPS AND COLORS:
Item Description Put-Up (ft.) Ship Weight (lbs.) Jacket Color Notes
9272 006100 78 OHM TWINAX 100 3.7 BLUE, LIGHT
9272 0061000 78 OHM TWINAX 1000 41 BLUE, LIGHT C
9272 006500 78 OHM TWINAX 500 18.5 BLUE, LIGHT C
9272 006U1000 78 OHM TWINAX U1000 39 BLUE, LIGHT
9272 006U500 78 OHM TWINAX U500 20 BLUE, LIGHT
C = CRATE REEL PUT-UP. |
|
|
|
|