商品編號: Belden-89182,google,industrial
Belden89182 Twinax - Twinaxial Cable FEP Teflon® insulation, Duofoil® (100% coverage) plus a stranded tinned copper drain wire, FEP Teflon jacket. cmp CL2P
DESCRIPTION:
22 AWG stranded (19x34) tinned copper conductors, foam FEP Teflon® insulation, Duofoil® (100% coverage) plus a stranded tinned copper drain wire, FEP Teflon jacket.
PHYSICAL CHARACTERISTICS :
CONDUCTOR :
Number of Pairs: 1
Total Number of Conductors: 2
AWG: 22
Stranding: 19x34
Conductor Diameter: .031 in.
Conductor Material: TC - Tinned Copper
INSULATION :
Insulation Material Trade Name: Teflon®
Insulation Material: FFEP - Foam Fluorinated Ethylene Propylene
Insulation Diameter: .278 in.
PAIR :
Pair Lay Length & Direction:
Lay Length (in.) Direction Twists/ft (twist/ft)
3 Left Hand 4
Pair Diameter: .278 in.
Pair Color Code Chart:
Number Color
1 Black & Yellow
OUTER SHIELD :
Outer Shield Trade Name: Duofoil®
Outer Shield Type: Tape
Outer Shield Material: Aluminum Foil-Polyester Tape-Aluminum Foil
Outer Shield %Coverage: 100 %
OUTER SHIELD DRAIN WIRE :
Outer Shield Drain Wire AWG: 22
Outer Shield Drain Wire Stranding: 19x34
Outer Shield Drain Wire Conductor Material: TC - Tinned Copper
OUTER JACKET :
Outer Jacket Material Trade Name: Teflon®
Outer Jacket Material: FEP - Fluorinated Ethylene Propylene
OVERALL NOMINAL DIAMETER :
Overall Nominal Diameter: .307 in.
MECHANICAL CHARACTERISTICS :
Operating Temperature Range: -70°C To +200°C
Bulk Cable Weight: 48.7 lbs/1000 ft.
Max. Recommended Pulling Tension: 28 lbs.
Min. Bend Radius (Install): 3.5 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE :
APPLICABLE STANDARDS :
NEC/(UL) Specification: CMP, CL2P
CEC/C(UL) Specification: CMP
EU RoHS Compliant (Y/N): Yes
EU RoHS Compliance Date (mm/dd/yyyy):: 04/01/2005
FLAME TEST :
UL Flame Test: NFPA 262
C(UL) Flame Test: FT6
PLENUM/NON-PLENUM :
Plenum (Y/N): Y
Non-Plenum Number: 9182
ELECTRICAL CHARACTERISTICS :
Nom. Characteristic Impedance: 150 Ω
Nom. Inductance: 0.29 µH/ft
Nom. Capacitance Conductor to Conductor @ 1 KHz: 8.8 pF/ft
Nom. Cap. Cond. to Other Cond. & Shield @ 1 KHz: 16.5 pF/ft
Nominal Velocity of Propagation: 78 %
Nominal Delay: 1.3 ns/ft
Nom. Conductor DC Resistance @ 20 Deg. C: 14.0 Ω/1000 ft
Nominal Outer Shield DC Resistance: 6.3 Ω/1000 ft
Nom. Attenuation:
Description Frequency (MHz) Start Frequency (MHz) Stop Frequency (MHz) Nom. Attenuation (dB/100 ft.)
1 0.4
10 1.2
50 2.7
100 4.3
200 6.2
400 8.8
Max. Operating Voltage - UL: 300 V RMS (CMP), 150 V RMS (CL2P)
NOTES :
Notes: Teflon® is a registered trademark of E. I. duPont de Nemours and Co. used under license by Belden, Inc. Other MaximumContinuous Currrents: 2.9 Amps per conductor @ 25°C
PUT-UPS AND COLORS:
Item Description Put-Up (ft.) Ship Weight (lbs.) Jacket Color Notes
89182 010100 2 #22 FFEP FS FEP 100 6.4 BLACK C
89182 0101000 2 #22 FFEP FS FEP 1000 53 BLACK C
89182 010500 2 #22 FFEP FS FEP 500 28 BLACK C
C = CRATE REEL PUT-UP.
|
|
|
|
|