商品編號: Belden-8424
Belden 8424 Non-Paired - Four-Conductor Star Quad, Low-Impedance Microphone Cable 4根導体星绞型低阻抗麥克風和樂器電缆
20 AWG stranded (26x34) high-conductivity tinned copper conductors, EPDM rubber insulation, rayon braid, TC braid shield (85% coverage), cotton wrap, EPDM rubber jacket.
8424
|
|
Multi-Conductor - Four-Conductor Star Quad, Low-Impedance Cable
20 AWG stranded (26x34) high-conductivity tinned copper conductors, EPDM rubber insulation, rayon braid, TC braid shield (85% coverage), cotton wrap, EPDM rubber jacket. |
For more Information
please call
1-800-Belden1 |
Click here for Certificate
Item # |
Putup |
Ship Weight |
Color |
Notes |
Item Desc |
8424 010U500 |
500 FT |
32.000 LB |
BLACK |
|
4 #20 EPDM SHLD EPDM |
8424 010100 |
100 FT |
6.800 LB |
BLACK |
|
4 #20 EPDM SHLD EPDM |
8424 0101000 |
1,000 FT |
64.000 LB |
BLACK |
C |
4 #20 EPDM BRD EPDM |
8424 010250 |
250 FT |
16.750 LB |
BLACK |
C |
4 #20 EPDM BRD EPDM |
8424 010500 |
500 FT |
32.000 LB |
BLACK |
C |
4 #20 EPDM BRD EPDM |
|
Notes: |
|
C = CRATE REEL PUT-UP.
|
Physical
Characteristics
(Overall)
Conductor
AWG:
# Conductors |
AWG |
Stranding |
Conductor Material |
Dia. (in.) |
4 |
20 |
26x34 |
High Conductivity TC - Tinned Copper |
.037 |
|
Total Number of Conductors: |
4 |
Insulation
Insulation
Material:
Insulation Material |
Wall Thickness (in.) |
Dia. (in.) |
EPDM - Ethylene Propylene Diene Monomer Rubber |
.023 |
.083 |
|
Outer
Shield
Outer
Shield
Material:
Type |
Outer Shield Material |
Coverage (%) |
Braid |
TC - Tinned Copper |
85 |
|
Outer Shield Separator Material: |
Cotton Wrap |
Outer
Jacket
Outer
Jacket
Material:
Outer Jacket Material |
Nom. Wall Thickness (in.) |
EPDM - Ethylene Propylene Diene Monomer Rubber |
.036 |
|
Overall
Cable
Overall
Cabling
Color
Code
Chart:
Number |
Color |
1 |
Black |
2 |
White |
3 |
Red |
4 |
Green |
|
Overall Cabling Separator Material: |
Rayon Braid |
Overall Nominal Diameter: |
0.294 in. |
Mechanical
Characteristics
(Overall)
Operating Temperature Range: |
-50°C To +90°C |
Non-UL Temperature Rating: |
60°C |
Bulk Cable Weight: |
61 lbs/1000 ft. |
Max. Recommended Pulling Tension: |
87 lbs. |
Min. Bend Radius/Minor Axis: |
3 in. |
Applicable
Specifications
and
Agency
Compliance
(Overall)
Applicable
Standards
&
Environmental
Programs
EU Directive 2011/65/EU (ROHS II): |
Yes |
EU Directive 2000/53/EC (ELV): |
Yes |
EU Directive 2002/95/EC (RoHS): |
Yes |
EU RoHS Compliance Date (mm/dd/yyyy): |
01/01/2004 |
EU Directive 2002/96/EC (WEEE): |
Yes |
EU Directive 2003/11/EC (BFR): |
Yes |
CA Prop 65 (CJ for Wire & Cable): |
Yes |
MII Order #39 (China RoHS): |
Yes |
Plenum/Non-Plenum
Electrical
Characteristics
(Overall)
Nom.
Characteristic
Impedance:
Nom.
Inductance:
Nom.
Capacitance
Conductor
to
Conductor:
Nom.
Cap.
Between
Cond.
in
a
Quad
Config.:
Nominal
Velocity
of
Propagation:
Nom.
Conductor
DC
Resistance:
DCR @ 20°C (Ohm/1000 ft) |
10.2 |
|
Nominal
Outer
Shield
DC
Resistance:
DCR @ 20°C (Ohm/1000 ft) |
3.2 |
|
Max.
Operating
Voltage
-
UL:
Max.
Recommended
Current:
Current |
3.2 Amps per conductor @ 25°C |
|
Other Electrical Characteristic 1: |
2/c 17AWG equivalent DCR when connected to a 3-pin XLR |
Notes
(Overall)
Notes: |
Quad connection scheme: The black and red wires (or wires directly opposite one another) are connected together to form one conductor, and similarly the white and green wires (or remaining wires) are connected together to form the second conductor. |
|