9414  | | Multi-Conductor - Audio, Control and Instrumentation Cable 22 AWG stranded (7x30) tinned copper conductors, semi-rigid PVC insulation, twisted pair, overall Beldfoil® shield (100% coverage), 22 AWG stranded TC drain wire, jacket-striated PVC. | For more Information please call 1-800-Belden1 |
| Item # | Putup | Ship Weight | Color | Notes | Item Desc | | 9414 T35U1000 | 1,000 FT | 23.000 LB | BEIGE, PALE FAWN | | 2 #22 PVC SHLD FRPVC | | 9414 T35U500 | 500 FT | 12.000 LB | BEIGE, PALE FAWN | | 2 #22 PVC SHLD FRPVC | | 9414 T351000 | 1,000 FT | 23.000 LB | BEIGE, PALE FAWN | C | 2 #22 PVC SHLD FRPVC | | 9414 T35500 | 500 FT | 11.500 LB | BEIGE, PALE FAWN | | 2 #22 PVC SHLD FRPVC | |
| Notes: | |
C = CRATE REEL PUT-UP. |
Physical Characteristics (Overall)
Conductor
AWG:
| # Pairs | AWG | Stranding | Conductor Material | | 1 | 22 | 7x30 | TC - Tinned Copper | |
Insulation
Insulation Material:
| Insulation Material | Wall Thickness (in.) | | S-R PVC - Semi-Rigid Polyvinyl Chloride | .010 | |
Outer Shield
Outer Shield Material:
| Outer Shield Trade Name | Type | Outer Shield Material | Coverage (%) | | Beldfoil® | Tape | Aluminum Foil-Polyester Tape | 100 | |
Outer Shield Drain Wire AWG:
| AWG | Stranding | Drain Wire Conductor Material | | 22 | 7x30 | TC - Tinned Copper | |
Outer Jacket
Outer Jacket Material:
| Outer Jacket Material | Nom. Wall Thickness (in.) | | PVC - Polyvinyl Chloride | .035 | |
Overall Cabling
| Overall Nominal Diameter: | 0.186 in. |
Pair
Pair Color Code Chart:
| Number | Color | | 1 | Black & White | |
Pair Lay Length & Direction:
| Lay Length (in.) | Twists/ft. (twist/ft) | | 1.250 | 9.600 | |
Mechanical Characteristics (Overall)
| Operating Temperature Range: | -20°C To +80°C |
| UL Temperature Rating: | 80°C (UL AWM Style 2464) |
| Bulk Cable Weight: | 20.300 lbs/1000 ft. |
| Max. Recommended Pulling Tension: | 27 lbs. |
| Min. Bend Radius (Install)/Minor Axis: | 1.800 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
| NEC/(UL) Specification: | CMG |
| CEC/C(UL) Specification: | CMG |
| AWM Specification: | UL Style 2464 (300 V 80°C) |
| EU Directive 2000/53/EC (ELV): | Yes |
| EU Directive 2002/95/EC (RoHS): | Yes |
| EU RoHS Compliance Date (mm/dd/yyyy): | 10/01/2005 |
| EU Directive 2002/96/EC (WEEE): | Yes |
| EU Directive 2003/11/EC (BFR): | Yes |
| CA Prop 65 (CJ for Wire & Cable): | Yes |
| MII Order #39 (China RoHS): | Yes |
Flame Test
Plenum/Non-Plenum
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Nom. Inductance:
Nom. Capacitance Conductor to Conductor:
Nom. Capacitance Cond. to Other Conductor & Shield:
Nom. Conductor DC Resistance:
| DCR @ 20°C (Ohm/1000 ft) | | 16 | |
Nominal Outer Shield DC Resistance:
| DCR @ 20°C (Ohm/1000 ft) | | 12.5 | |
Max. Operating Voltage - UL:
| Voltage | | 300 V RMS (UL AWM Style 2464) | |
Max. Recommended Current:
| Current | | 2.9 Amps per conductor @ 25°C | |