8762 | | Multi-Conductor - Single-Pair Cable 20 AWG stranded (7x28) TC conductors, polyethylene insulation, twisted pair, overall Beldfoil® shield (100% coverage), 20 AWG stranded TC drain wire, PVC jacket. | For more Information please call 1-800-Belden1 |
Item # | Putup | Ship Weight | Color | Notes | Item Desc | 8762 060U1000 | 1,000 FT | 23.000 LB | CHROME | | 2 #20 PE FS PVC | 8762 060U500 | 500 FT | 12.500 LB | CHROME | | 2 #20 PE FS PVC | 8762 060100 | 100 FT | 2.900 LB | CHROME | | 2 #20 PE FS PVC | 8762 0601000 | 1,000 FT | 23.000 LB | CHROME | C | 2 #20 PE FS PVC | 8762 06010000 | 10,000 FT | 240.000 LB | CHROME | C Y | 2 #20 PE FS PVC | 8762 0602000 | 2,000 FT | 46.000 LB | CHROME | C | 2 #20 PE FS PVC | 8762 060250 | 250 FT | 6.250 LB | CHROME | | 2 #20 PE FS PVC | 8762 060500 | 500 FT | 12.000 LB | CHROME | C | 2 #20 PE FS PVC | |
Notes: | |
C = CRATE REEL PUT-UP. Y = FINAL PUT-UP LENGTH MAY VARY -10% TO +20% FROM LENGTH SHOWN.MAY CONTAIN 2 PIECES. MINIMUM LENGTH OF ANY ONE PIECE IS 1500'. |
Physical Characteristics (Overall)
Conductor
AWG:
# Pairs | AWG | Stranding | Conductor Material | 1 | 20 | 7x28 | TC - Tinned Copper | |
Insulation
Insulation Material:
Insulation Material | Wall Thickness (in.) | PE - Polyethylene | .016 | |
Outer Shield
Outer Shield Material:
Outer Shield Trade Name | Type | Outer Shield Material | Coverage (%) | Beldfoil® | Tape | Aluminum Foil-Polyester Tape w/Shorting Fold | 100 | |
Outer Shield Drain Wire AWG:
AWG | Stranding | Drain Wire Conductor Material | 20 | 7x28 | TC - Tinned Copper | |
Outer Jacket
Outer Jacket Material:
Outer Jacket Material | Nom. Wall Thickness (in.) | PVC - Polyvinyl Chloride | .028 | |
Overall Cabling
Overall Nominal Diameter: | 0.204 in. |
Pair
Pair Color Code Chart:
Number | Color | 1 | Black & Clear | |
Pair Lay Length & Direction:
Lay Length (in.) | Twists/ft. (twist/ft) | 1.500 | 8.000 | |
Mechanical Characteristics (Overall)
Operating Temperature Range: | -20°C To +60°C |
UL Temperature Rating: | 60°C (UL AWM Style 2092) |
Bulk Cable Weight: | 21.200 lbs/1000 ft. |
Max. Recommended Pulling Tension: | 46 lbs. |
Min. Bend Radius (Install)/Minor Axis: | 2 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: | CM |
CEC/C(UL) Specification: | CM |
AWM Specification: | UL Style 2092 (300 V 60°C) |
EU Directive 2000/53/EC (ELV): | Yes |
EU Directive 2002/95/EC (RoHS): | Yes |
EU RoHS Compliance Date (mm/dd/yyyy): | 01/01/2004 |
EU Directive 2002/96/EC (WEEE): | Yes |
EU Directive 2003/11/EC (BFR): | Yes |
CA Prop 65 (CJ for Wire & Cable): | Yes |
MII Order #39 (China RoHS): | Yes |
Flame Test
UL Flame Test: | UL1685 UL Loading |
Plenum/Non-Plenum
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Nom. Inductance:
Nom. Capacitance Conductor to Conductor:
Nom. Capacitance Cond. to Other Conductor & Shield:
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/1000 ft) | 9.5 | |
Max. Operating Voltage - UL:
Max. Recommended Current:
Current | 3.9 Amps per conductor @ 25°C | |