9460  | | Multi-Conductor - Single-Pair Cable 18 AWG stranded (16x30) TC conductors, polyethylene insulation, twisted pair, overall Beldfoil® shield (100% coverage), 20 AWG stranded TC drain wire, PVC jacket. | For more Information please call 1-800-Belden1 |
| Item # | Putup | Ship Weight | Color | Notes | Item Desc | | 9460 0105000 | 5,000 FT | 180.000 LB | BLACK | C Z | 1 PR #18 LDPE FS PVC | | 9460 060U1000 | 1,000 FT | 36.000 LB | CHROME | | 1 PR #18 LDPE FS PVC | | 9460 060U500 | 500 FT | 18.500 LB | CHROME | | 1 PR #18 LDPE FS PVC | |
| Notes: | |
C = CRATE REEL PUT-UP. Z = FINAL PUT-UP LENGTH MAY VARY (+ OR -) 10% FOR SPOOLS OR REELS AND(+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN. |
Physical Characteristics (Overall)
Conductor
AWG:
| # Pairs | AWG | Stranding | Conductor Material | | 1 | 18 | 16x30 | TC - Tinned Copper | |
Insulation
Insulation Material:
| Insulation Material | Wall Thickness (in.) | | PE - Polyethylene | .019 | |
Outer Shield
Outer Shield Material:
| Outer Shield Trade Name | Type | Outer Shield Material | Coverage (%) | | Beldfoil® | Tape | Aluminum Foil-Polyester Tape | 100 | |
Outer Shield Drain Wire AWG:
| AWG | Stranding | Drain Wire Conductor Material | | 20 | Stranded | TC - Tinned Copper | |
Outer Jacket
Outer Jacket Material:
| Outer Jacket Material | Nom. Wall Thickness (in.) | | PVC - Polyvinyl Chloride | .030 | |
Overall Cabling
| Overall Nominal Diameter: | 0.230 in. |
Pair
Pair Color Code Chart:
| Number | Color | | 1 | Black & Clear | |
Pair Lay Length & Direction:
| Lay Length (in.) | Twists/ft. (twist/ft) | | 1.500 | 8.000 | |
Mechanical Characteristics (Overall)
| Operating Temperature Range: | -20°C To +60°C |
| UL Temperature Rating: | 60°C (UL AWM Style 2092) |
| Bulk Cable Weight: | 34.200 lbs/1000 ft. |
| Max. Recommended Pulling Tension: | 70 lbs. |
| Min. Bend Radius (Install)/Minor Axis: | 2.250 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
| NEC/(UL) Specification: | CM |
| CEC/C(UL) Specification: | CM |
| AWM Specification: | UL Style 2092 (300 V 60°C) |
| EU Directive 2000/53/EC (ELV): | Yes |
| EU Directive 2002/95/EC (RoHS): | Yes |
| EU RoHS Compliance Date (mm/dd/yyyy): | 01/01/2004 |
| EU Directive 2002/96/EC (WEEE): | Yes |
| EU Directive 2003/11/EC (BFR): | Yes |
| CA Prop 65 (CJ for Wire & Cable): | Yes |
| MII Order #39 (China RoHS): | Yes |
Flame Test
| UL Flame Test: | UL1685 UL Loading |
Plenum/Non-Plenum
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Nom. Inductance:
Nom. Capacitance Conductor to Conductor:
Nom. Capacitance Cond. to Other Conductor & Shield:
Nom. Conductor DC Resistance:
| DCR @ 20°C (Ohm/1000 ft) | | 6.5 | |
Max. Operating Voltage - UL:
| Voltage | | 300 V RMS (UL AWM Style 2092) | |
Max. Recommended Current:
| Current | | 5.2 Amps per conductor @ 25°C | |
Notes (Overall)
| Notes: | The jacket and shield are bonded so both can be removed on automatic stripping equipment. Drain wire is on the inside of foil shield. |