商品編號: Belden 8471
8471 Paired - High-Conductivity Copper Speaker Cable Twisted Jacketed Con
16 AWG stranded (19x29) tinned copper conductors, PVC insulation, twisted pair, PVC jacket
8471
|
|
Multi-Conductor - High-Conductivity Copper Speaker Cable Twisted Jacketed Con
16 AWG stranded (19x29) tinned copper conductors, PVC insulation, twisted pair, PVC jacket. |
For more Information
please call
1-800-Belden1 |
| Item # |
Putup |
Ship Weight |
Color |
Notes |
Item Desc |
| 8471 060U1000 |
1,000 FT |
38.000 LB |
CHROME |
|
1 PR #16 PVC FRPVC |
| 8471 060U500 |
500 FT |
19.500 LB |
CHROME |
|
1 PR #16 PVC FRPVC |
| 8471 0601000 |
1,000 FT |
40.000 LB |
CHROME |
C |
1 PR #16 PVC FRPVC |
| 8471 060500 |
500 FT |
20.000 LB |
CHROME |
C |
1 PR #16 PVC FRPVC |
| 8471 0605000 |
5,000 FT |
195.000 LB |
CHROME |
|
1 PR #16 PVC FRPVC |
|
| Notes: |
|
C = CRATE REEL PUT-UP.
|
Physical Characteristics (Overall)
Conductor
AWG:
| # Pairs |
AWG |
Stranding |
Conductor Material |
| 1 |
16 |
19x29 |
TC - Tinned Copper |
|
Insulation
Insulation Material:
| Insulation Material |
Wall Thickness (in.) |
| PVC - Polyvinyl Chloride |
.023 |
|
Inner Shield
Inner Shield Material:
| Inner Shield Material |
| Unshielded |
|
Outer Shield
Outer Shield Material:
| Outer Shield Material |
| Unshielded |
|
Outer Jacket
Outer Jacket Material:
| Outer Jacket Material |
Nom. Wall Thickness (in.) |
| PVC - Polyvinyl Chloride |
.032 |
|
Overall Cabling
| Overall Nominal Diameter: |
0.274 in. |
Pair
Pair Color Code Chart:
| Number |
Color |
| 1 |
Black & White |
|
Pair Lay Length & Direction:
| Lay Length (in.) |
Twists/ft. (twist/ft) |
| 2.000 |
6.000 |
|
Mechanical Characteristics (Overall)
| Operating Temperature Range: |
-20°C To +80°C |
| Non-UL Temperature Rating: |
60°C (UL AWM Style 2598) |
| Bulk Cable Weight: |
35.900 lbs/1000 ft. |
| Max. Recommended Pulling Tension: |
61 lbs. |
| Min. Bend Radius (Install)/Minor Axis: |
5.100 in. |
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
| NEC/(UL) Specification: |
CMG |
| CEC/C(UL) Specification: |
CMG |
| AWM Specification: |
UL Style 2598 (300 V 60°C) |
| EU Directive 2000/53/EC (ELV): |
Yes |
| EU Directive 2002/95/EC (RoHS): |
Yes |
| EU RoHS Compliance Date (mm/dd/yyyy): |
04/01/2005 |
| EU Directive 2002/96/EC (WEEE): |
Yes |
| EU Directive 2003/11/EC (BFR): |
Yes |
| CA Prop 65 (CJ for Wire & Cable): |
Yes |
| MII Order #39 (China RoHS): |
Yes |
Flame Test
| UL Flame Test: |
UL1685 FT4 Loading |
Plenum/Non-Plenum
Electrical Characteristics (Overall)
Nom. Inductance:
Nom. Capacitance Conductor to Conductor:
Nom. Conductor DC Resistance:
| DCR @ 20°C (Ohm/1000 ft) |
| 4.49 |
|
Max. Operating Voltage - UL:
| Voltage |
| 300 V RMS (UL AWM Style 2598) |
|
Max. Recommended Current:
| Current |
| 7.1 Amps per conductor @ 25°C |
|
Notes (Overall)
| Notes: |
Nominal Breakdown Voltage - Jacket 20 KV RMS; Nominal Breakdown Voltage Between Conductors 20 KV RMS. |
|
|
|
|
|